This manual provides essential information for the installation, operation, and maintenance of the Allen Bradley 1734-Ib8s Ser B, Point Guard I/O Safety Input Module 1734-Ib8s Series B. Please read this manual thoroughly before using the device to ensure safe and efficient operation.

The Allen Bradley 1734-IB8S Series B is a Digital Input Module 24VDC 8-Ch Sink Safety, designed for industrial automation applications.

2. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Allen Bradley 1734-IB8S Series B is a Digital Input Module designed for industrial automation applications. It features 8 safety-rated sink inputs for 24V DC systems.

Allen Bradley 1734-IB8S Series B module in its factory sealed box.

Figure 2.1: Allen Bradley 1734-IB8S Series B module in its factory sealed box, showing the product label with CAT 1734-IB8S and serial number.

Close-up of the Allen Bradley 1734-IB8S Series B module box, highlighting the factory seal and product information.

ചിത്രം 2.2: ക്ലോസപ്പ് view of the product packaging for the 1734-IB8S module, emphasizing the factory seal and key identification numbers like CAT 1734-IB8S and the barcode 10612598350619.

പ്രധാന സവിശേഷതകളിൽ ഇവ ഉൾപ്പെടുന്നു:

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Proper installation is crucial for the safe and reliable operation of the 1734-IB8S module. Follow these steps carefully:

  1. വൈദ്യുതി വിച്ഛേദിക്കൽ: Ensure all power to the control system is disconnected before beginning installation.
  2. മൗണ്ടിംഗ്: Mount the module onto a compatible POINT I/O backplane or DIN rail. Ensure it is securely latched.
  3. വയറിംഗ്: Connect the 24V DC power supply to the module's power terminals. Wire the safety input devices to the designated input channels. Refer to the system wiring diagrams for specific connections.
  4. ഗ്രൗണ്ടിംഗ്: Ensure proper grounding of the module and associated equipment to prevent electrical hazards and ensure signal integrity.
  5. സ്ഥിരീകരണം: Double-check all wiring connections for correctness and security before reapplying power.

കുറിപ്പ്: Always consult the complete system documentation for detailed wiring diagrams and safety guidelines.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Once installed and powered, the 1734-IB8S module operates as part of the larger control system. Its primary function is to monitor the state of 8 safety-rated sink inputs.

പ്രധാനപ്പെട്ടത്: Do not attempt to bypass or modify safety circuits. Always follow established safety procedures.

5. പരിപാലനം

The 1734-IB8S module is designed for minimal maintenance. However, periodic checks can help ensure long-term reliability.

ജാഗ്രത: Always disconnect power before performing any maintenance or cleaning procedures.

6. പ്രശ്‌നപരിഹാരം

This section provides guidance for common issues encountered with the 1734-IB8S module.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
Module LEDs are offNo power to module or backplane.Check power supply connections and ensure backplane power is active.
Input LED not illuminatingInput device not active, wiring error, or faulty input device.Verify input device operation. Check wiring for breaks or shorts. Test input device.
Module not communicating with PLCIncorrect module configuration, PointBus issue, or PLC programming error.Verify module configuration in PLC software. Check PointBus connections. Review പി‌എൽ‌സി പ്രോഗ്രാം ലോജിക്.

If troubleshooting steps do not resolve the issue, contact Allen-Bradley technical support.

7 സ്പെസിഫിക്കേഷനുകൾ

Detailed technical specifications for the Allen Bradley 1734-IB8S Series B module:

8. വാറൻ്റിയും പിന്തുണയും

For information regarding product warranty, technical support, and service, please refer to the official Allen-Bradley or Rockwell Automation webസൈറ്റ്, അല്ലെങ്കിൽ നിങ്ങളുടെ അംഗീകൃത വിതരണക്കാരനെ ബന്ധപ്പെടുക.

ഓൺലൈൻ ഉറവിടങ്ങൾ: സന്ദർശിക്കുക റോക്ക്വെൽ ഓട്ടോമേഷൻ webസൈറ്റ് for product documentation, software downloads, and support forums.

സാങ്കേതിക സഹായം: Contact Allen-Bradley technical support for assistance with product issues, configuration, or advanced troubleshooting.

അനുബന്ധ രേഖകൾ - 1734-IB8S

പ്രീview POINT Guard I/O Safety Modules User Manual
User manual for Allen-Bradley POINT Guard I/O Safety Modules (1734-IB8S, 1734-OB8S, 1734-IE4S, 1734-OBV2S), detailing installation, configuration, and operation for industrial safety applications.
പ്രീview Allen-Bradley POINT I/O Input Modules Installation Guide (Series D)
Comprehensive installation and wiring guide for Allen-Bradley POINT I/O Digital DC Input Modules (Series D), covering catalog numbers 1734-IB2, 1734-IB4, 1734-IB4K, 1734-IB8, and 1734-IB8K. Includes setup procedures, hazardous location information, communication details, status indicators, and technical specifications.
പ്രീview പോയിന്റ് I/O 2 കറന്റും 2 വോളിയവുംtage Input Analog Modules Installation Instructions
Installation instructions for Rockwell Automation's POINT I/O 2 Current and 2 Voltage Input Analog Modules (Series C), including catalog numbers 1734-IE2C, 1734-IE2CK, 1734-IE2V, and 1734-IE2VK. Covers installation, wiring, status indicators, specifications, and hazardous location approvals.
പ്രീview Allen-Bradley POINT I/O Source Input Modules Installation Instructions
This document provides installation instructions for Allen-Bradley POINT I/O Source Input Modules, including catalog numbers 1734-IV2, 1734-IV4, 1734-IV8, and 1734-IV8K, Series C. It covers topics such as environment and enclosure, hazardous location approvals, wiring, communication, status indicators, and specifications.
പ്രീview Allen-Bradley POINT I/O Output Module Installation Instructions
This document provides essential installation instructions for the Allen-Bradley POINT I/O Output Module, covering setup, wiring, and status indicators for models 1734-OB2, 1734-OB4, 1734-OB4K, 1734-OB8, and 1734-OB8K.
പ്രീview Allen-Bradley POINT I/O Protected Output Module Installation Guide
Comprehensive installation guide for the Allen-Bradley POINT I/O Protected Output Module, Series C (Catalog Number 1734-OB2EP). Covers setup, wiring, communication, status indicators, and technical specifications for industrial automation.