1. ആമുഖം
This manual provides detailed instructions for the installation, operation, and maintenance of the uxcell M20x1.5 Cable Gland. These cable glands are designed to provide a secure and waterproof seal for cables entering electrical enclosures, junction boxes, and other equipment. They are constructed from durable plastic and feature an adjustable locknut for various cable diameters, ensuring protection against water, dust, acids, and alcohol.
ഇൻസ്റ്റാൾ ചെയ്യുന്നതിന് മുമ്പ് ദയവായി ഈ മാനുവൽ നന്നായി വായിക്കുകയും ഭാവിയിലെ റഫറൻസിനായി സൂക്ഷിക്കുകയും ചെയ്യുക.
2 സുരക്ഷാ വിവരങ്ങൾ
WARNING: Always disconnect power before working on electrical systems to prevent electric shock.
- Ensure all installations comply with local electrical codes and regulations.
- കയ്യുറകളും നേത്ര സംരക്ഷണവും പോലുള്ള ഉചിതമായ വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ (പിപിഇ) ഉപയോഗിക്കുക.
- Do not overtighten the cable gland, as this may damage the cable or the gland itself.
- Verify the cable gland's compatibility with the cable diameter and the enclosure's thread size before installation.
- കുട്ടികൾക്ക് ലഭ്യമാകാതെ സൂക്ഷിക്കുക.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The uxcell M20x1.5 Cable Gland is designed for robust cable management and sealing. Each gland consists of several key components that work together to provide a secure and protective connection.

Figure 3.1: Four uxcell M20x1.5 Cable Glands. These glands are designed for securing and sealing cables in various electrical applications.

ചിത്രം 3.2: ക്ലോസപ്പ് view of two M20x1.5 cable glands, highlighting the thread size and overall design.

Figure 3.3: Various application scenarios for the cable glands, demonstrating their use in junction boxes and control panels.
പ്രധാന സവിശേഷതകൾ:
- തരം: M20x1.5 thread size.
- Cable Diameter Compatibility: Fits cables with diameters ranging from 6mm to 12mm (0.24inch to 0.47inch).
- മെറ്റീരിയൽ: മോടിയുള്ള പ്ലാസ്റ്റിക് നിർമ്മാണം.
- സംരക്ഷണം: Provides waterproof, dust-proof, anti-acid, and anti-alcohol sealing.
- ഇൻസ്റ്റലേഷൻ എളുപ്പം: Designed for simple and quick clamping of cables.
- അപേക്ഷ: Ideal for use with junction boxes and other electrical enclosures.
4 സ്പെസിഫിക്കേഷനുകൾ
The following table details the technical specifications for the uxcell M20x1.5 Cable Gland:
| ആട്രിബ്യൂട്ട് | മൂല്യം |
|---|---|
| ടൈപ്പ് ചെയ്യുക | M20x1.5 |
| Fit for Cable Diameter | 6 മിമി-12 മിമി (0.24 ഇഞ്ച്-0.47 ഇഞ്ച്) |
| ത്രെഡ് വ്യാസം | 20 മിമി (0.79 ഇഞ്ച്) |
| ത്രെഡ് നീളം | 10 മിമി (0.39 ഇഞ്ച്) |
| മെറ്റീരിയൽ | പ്ലാസ്റ്റിക് |
| നിറം | കറുപ്പ് |
| ഇനത്തിൻ്റെ പാക്കേജ് അളവ് | 4 പീസുകൾ |
| ഇനത്തിൻ്റെ ഭാരം | 1.58 ounces (for the package) |
| മോഡൽ നമ്പർ | a18032200ux0250 |
| സംരക്ഷണ സവിശേഷതകൾ | Waterproof, Dust-proof, Anti-acid, Anti-alcohol |

Figure 4.1: Normal Parameter Table for various cable gland models, including M20.
5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Follow these steps for proper installation of the uxcell M20x1.5 Cable Gland to ensure a secure and sealed connection.
- Prepare the Enclosure: Ensure the electrical enclosure or junction box has a pre-drilled hole with an M20x1.5 thread, or a suitable hole for the gland's thread diameter (approximately 20mm).

Figure 5.1: Visual guide for measuring hole diameter and cable diameter, and the gland installation process.
- Disassemble the Gland: Unscrew the sealing nut from the main body of the cable gland. The gland typically consists of a main body (with external thread), a sealing washer, a claw/clamping part, and a sealing nut.
- Insert Main Body: Insert the threaded main body of the cable gland into the prepared hole from the outside of the enclosure.
- Secure with Locknut: From the inside of the enclosure, screw on the locknut (if provided separately, otherwise the main body itself has a flange) to secure the gland to the enclosure. Tighten firmly by hand, then use a wrench for a final snug fit, but do not overtighten.
- കേബിൾ ചേർക്കുക: Pass the cable through the sealing nut, then through the clamping part, and finally through the main body of the gland. Ensure the cable is centered.
- Tighten Sealing Nut: Screw the sealing nut onto the main body of the gland. As you tighten, the internal clamping part will compress around the cable, creating a tight seal.

Figure 5.2: Comparison illustrating a properly sealed connection versus a water-resistant one, emphasizing the importance of correct tightening.
- സീൽ പരിശോധിക്കുക: Ensure the cable is firmly gripped and there is no visible gap between the gland and the cable or the gland and the enclosure. The seal should be snug to provide waterproof and dust-proof protection.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once properly installed, the uxcell M20x1.5 Cable Gland operates passively by maintaining a secure and sealed entry point for your cable. No further operational steps are required beyond ensuring the initial installation is correct and the gland remains securely tightened.
7. പരിപാലനം
The uxcell M20x1.5 Cable Gland requires minimal maintenance. Regular inspection is recommended to ensure continued performance.
- ആനുകാലിക പരിശോധന: Periodically check the cable glands for any signs of loosening, cracking, or damage, especially in environments with vibration or extreme temperature fluctuations.
- വൃത്തിയാക്കൽ: If necessary, clean the exterior of the cable gland with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could degrade the plastic material.
- Re-tightening: If a gland appears loose, gently re-tighten the sealing nut to restore the seal. Do not overtighten.
- മാറ്റിസ്ഥാപിക്കൽ: If a cable gland shows significant wear, cracking, or can no longer maintain a proper seal, replace it immediately to ensure continued protection of your electrical system.
8. പ്രശ്നപരിഹാരം
Here are some common issues and their solutions related to the uxcell M20x1.5 Cable Gland:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Water/Dust Ingress | Gland not tightened sufficiently; incorrect cable diameter; damaged sealing washer. | Ensure the sealing nut is tightened firmly. Verify cable diameter is within 6mm-12mm range. Inspect and replace if sealing washer is damaged. |
| Cable Slippage | Sealing nut not tight enough; cable diameter too small for the gland's range. | Tighten the sealing nut further. If cable is too thin, use a smaller gland size or a different sealing method. |
| Gland does not fit enclosure hole | Incorrect hole size or thread type in the enclosure. | Verify the enclosure hole is M20x1.5 or approximately 20mm diameter. Use the correct size drill bit and tap if creating a new hole. |
| Gland cracking during installation | Overtightening; material fatigue. | Avoid excessive force when tightening. Replace the damaged gland. |
9. വാറണ്ടിയും പിന്തുണയും
For information regarding warranty coverage and customer support for your uxcell M20x1.5 Cable Gland, please refer to the product packaging or visit the official uxcell webസൈറ്റ്. വാങ്ങിയതിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
For technical assistance or inquiries, please contact uxcell customer service through their official channels.