1. ആമുഖം
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Afriso Thermostatic Radiator Head Type 320 N. This head is specifically designed for use with Gampper clamp connection valve bodies manufactured between 1980 and 1998. It also serves as a direct replacement for older Afriso models 313 and 314.
2. സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ
- Ensure the heating system is depressurized and cooled before attempting any installation or maintenance procedures.
- If you are unsure about the installation process, it is recommended to seek assistance from a qualified professional.
- Do not expose the thermostatic head to ambient temperatures exceeding 50 °C.
- Keep the product out of reach of children to prevent accidental damage or misuse.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Afriso Thermostatic Radiator Head Type 320 N is a precision-engineered control head that utilizes a liquid sensor to regulate room temperature by modulating the flow of hot water through a radiator. Its robust design ensures reliable performance and energy efficiency.
പ്രധാന സവിശേഷതകൾ:
- Liquid Sensor: Highly responsive to ambient temperature changes for accurate control.
- പൂജ്യം സ്ഥാനം: Allows for complete shut-off of the radiator, useful during warmer periods or for maintenance.
- Adjustable Economy Position: Enables setting a specific energy-saving temperature.
- Limitation Ring: Provides the ability to limit and lock the minimum and maximum temperature adjustment range.
- മെറ്റീരിയൽ: Constructed from durable plastic for longevity.
- കണക്ഷൻ: Features a Gampper clamp connection for secure and compatible fitting.

Figure 1: The Afriso Thermostatic Radiator Head Type 320 N, showing the temperature scale (0 to 5, with snowflake and wave symbols) and the Afriso logo. Two small red and blue plastic clips, used for limiting the temperature range, are also visible.

Figure 2: The product packaging for the Afriso Thermostat Control Head, displaying the brand 'Afriso' and the model '323 N' along with 'THERMOSTAT CONTROL HEAD' in English.
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
ഇൻസ്റ്റലേഷൻ നിർദ്ദേശങ്ങൾ:
- തയ്യാറാക്കൽ: Verify that your radiator valve body is compatible with a Gampper clamp connection. This head is designed for valve bodies manufactured between 1980 and 1998.
- പഴയ തലക്കെട്ട് നീക്കം ചെയ്യുക (ബാധകമെങ്കിൽ): If replacing an existing thermostatic head, carefully remove it according to its manufacturer's instructions.
- സ്ഥാനനിർണ്ണയം: Align the new Afriso Thermostatic Radiator Head with the valve body. The head features a specific Gampper clamp connection mechanism.
- സുരക്ഷിതമാക്കുന്നു: Gently push the thermostatic head onto the valve body. Ensure it is properly seated and then secure it firmly using the clamp connection. No tools are typically required for this step.
- പ്രാരംഭ ക്രമീകരണം: Once installed, set the head to your desired initial temperature.

ചിത്രം 3: ഒരു ക്ലോസ്-അപ്പ് view of the bottom of the Afriso Thermostatic Radiator Head, illustrating the Gampper clamp connection mechanism. The knurled metal ring and the internal structure for attachment to the radiator valve are clearly visible.

ചിത്രം 4: ഒരു വശം view of the thermostatic head, clearly displaying the 'Gampper' label and the clamp connection. The temperature scale and the internal liquid sensor mechanism are also visible.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The thermostatic head efficiently regulates the room temperature by automatically adjusting the flow of hot water through the radiator based on the ambient temperature.
താപനില ക്രമീകരിക്കൽ:
- Setting the Desired Temperature: Rotate the handwheel on the thermostatic head to align the desired room temperature setting with the indicator mark. The scale typically ranges from '0' (off/frost protection) to '5' (maximum heat).
- Frost Protection (Snowflake Symbol): Setting the head to the snowflake symbol (often found between '0' and '1') activates frost protection. This maintains a minimum temperature in the room to prevent pipes from freezing, typically around 6-8 °C.
- Economy Position: Utilize the adjustable economy position to set a specific energy-saving temperature, which can help reduce heating costs.
- Limiting the Range: If desired, use the provided limitation ring (often consisting of red and blue clips, as shown in Figure 1) to restrict the minimum and maximum temperature settings. This prevents accidental changes outside a preferred range.
The integrated liquid sensor continuously monitors the ambient room temperature. If the room temperature falls below the set value, the valve automatically opens further to allow more hot water into the radiator, increasing heat output. Conversely, if the room temperature exceeds the set value, the valve closes, reducing the heat output and maintaining the desired temperature.

Figure 5: A section of the product packaging displaying German text that explains the operational principle of the thermostat valve. It details how the handwheel sets the desired room temperature and how the temperature sensor continuously monitors and adjusts the valve to maintain this setting.
6. പരിപാലനം
പരിചരണവും ശുചീകരണവും:
- വൃത്തിയാക്കൽ: To clean the thermostatic head, simply wipe it with a soft, damp cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic surface.
- തടസ്സങ്ങൾ ഒഴിവാക്കുക: Ensure that the thermostatic head's sensor is not covered by curtains, furniture, or any other objects. Obstructions can impair the sensor's ability to accurately read the ambient room temperature, leading to inefficient heating.
- ആന്തരിക അറ്റകുറ്റപ്പണികൾ ഇല്ല: The Afriso Thermostatic Radiator Head is a sealed unit and does not require any internal maintenance. Do not attempt to disassemble the head, as this will void any warranty and may damage the unit.
7. പ്രശ്നപരിഹാരം
പൊതുവായ പ്രശ്നങ്ങളും പരിഹാരങ്ങളും:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| റേഡിയേറ്റർ ചൂടാക്കുന്നില്ല | Thermostatic head set to '0' or frost protection; valve pin stuck; air trapped in radiator. | Turn the head to a higher setting; gently press the valve pin to free it; bleed the radiator to release trapped air. |
| Room is too hot or too cold | Incorrect temperature setting; sensor obstructed; faulty thermostatic head. | Adjust the temperature setting; ensure the sensor is clear of obstructions; if persistent, the head may need replacement. |
| Thermostatic head is difficult to turn | Internal mechanism has become stiff or dirty. | Gently try to turn the head through its full range of motion a few times. If stiffness persists, consider replacing the head. |
For issues not listed above or if the problem persists after attempting these solutions, please contact customer support for further assistance.
8 സ്പെസിഫിക്കേഷനുകൾ
സാങ്കേതിക ഡാറ്റ:
- ബ്രാൻഡ്: അഫ്രിസോ
- മോഡൽ: Type 320 N
- അനുയോജ്യത: Gampper clamp connection valve bodies (manufactured 1980-1998)
- സെൻസർ തരം: ലിക്വിഡ് സെൻസർ
- പരമാവധി ആംബിയൻ്റ് താപനില: 50 °C
- മെറ്റീരിയൽ: പ്ലാസ്റ്റിക്
- നിറം: വെള്ള
- പാക്കേജ് അളവുകൾ: 9.4 x 5.5 x 5.5 സെ.മീ
- പാക്കേജ് ഭാരം: 156 ഗ്രാം
- നിർമ്മാതാവിൻ്റെ ഭാഗം നമ്പർ: 360 002
- ഇഎഎൻ/യുപിസി: 4049827065676
- പവർ സോഴ്സ് തരം: Manually powered
- ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾ: തെർമോസ്റ്റാറ്റിക് തല
- ആവശ്യമായ ബാറ്ററികൾ: ഇല്ല
9. വാറൻ്റിയും പിന്തുണയും
For detailed warranty information, technical support, or to inquire about spare parts, please refer to the official Afriso website or contact your authorized retailer. It is advisable to retain your purchase receipt as proof of purchase for any warranty claims.
- നിർമ്മാതാവ്: അഫ്രിസോ
- മോഡൽ നമ്പർ: 360 002