1. ആമുഖം
The uxcell 91C4 DC 0-10V Analog Panel Voltage Gauge is designed for measuring direct current (DC) voltage within a range of 0 to 10 volts. This instruction manual provides essential information for the safe installation, operation, and maintenance of the device. Please read this manual thoroughly before use.
2 സുരക്ഷാ വിവരങ്ങൾ
Always observe the following safety precautions to prevent personal injury or damage to the meter and other equipment:
- Ensure the power supply to the circuit being measured is disconnected before installation or wiring.
- വോളിയം എന്ന് പരിശോധിക്കുകtage to be measured does not exceed the meter's specified range (DC 0-10V).
- Connect the meter correctly according to the wiring diagram. Incorrect polarity can damage the meter.
- Do not use the meter in environments with excessive moisture, dust, or corrosive gases.
- This meter is designed for DC voltage measurement only. Do not connect to AC circuits.
- യോഗ്യതയുള്ള ഉദ്യോഗസ്ഥർ മാത്രമേ ഇൻസ്റ്റാളേഷനും പരിപാലനവും നടത്താവൂ.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The uxcell 91C4 is a compact analog panel voltmeter featuring a clear scale and a moving coil mechanism. It is designed for flush panel mounting.

ചിത്രം 1: ഫ്രണ്ട് view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter. This image displays the meter's face with its scale from 0 to 10 volts, the 'V' unit, the model number '91C4', and the accuracy class '2.5A'. The needle is positioned at zero, indicating no voltagഇ ഇൻപുട്ട്.

ചിത്രം 2: മുന്നിലും വശത്തും view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter with key dimensions. The image shows the meter's width and height as 45mm (1.77 inches) and its depth as 36mm (1.42 inches), providing essential information for panel cutout and mounting.
4 സ്പെസിഫിക്കേഷനുകൾ
| മോഡൽ | 91C4 |
| അളക്കൽ ശ്രേണി | ഡിസി ക്സനുമ്ക്സ-ക്സനുമ്ക്സവ് |
| കൃത്യത ക്ലാസ് | 2.5 (Error Margin: ± 2.5%) |
| ബിരുദം | 0.4V |
| Dimensions (L×W×T) | 45mm × 45mm × 36mm (1.77in × 1.77in × 1.42in) |
| മൊത്തം ഭാരം | 33 ഗ്രാം (1.16 ഔൺസ്) |
| Casing മെറ്റീരിയൽ | High-grade ABS Plastic |
| ഷണ്ട് റെസിസ്റ്റർ | ആവശ്യമില്ല |
| മൗണ്ടിംഗ് തരം | പാനൽ മ .ണ്ട് |
5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Follow these steps for proper installation of the voltage gauge:
- Prepare Panel Cutout: Create a square cutout in your panel with dimensions appropriate for the meter (approximately 45mm x 45mm). Ensure the cutout is clean and free of burrs.
- Insert Meter: Carefully insert the meter into the prepared panel cutout from the front.
- Secure Meter: From the rear of the panel, use the provided bolts and screws to secure the meter in place. Tighten them evenly to prevent damage to the meter casing.
- വയറിംഗ്:
- Identify the positive (+) and negative (-) terminals on the back of the meter.
- Connect the positive lead from the DC circuit to be measured to the meter's positive (+) terminal.
- Connect the negative lead from the DC circuit to be measured to the meter's negative (-) terminal.
- ഷോർട്ട് സർക്യൂട്ടുകൾ തടയാൻ എല്ലാ കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും ഇൻസുലേറ്റ് ചെയ്തിട്ടുണ്ടെന്നും ഉറപ്പാക്കുക.
- കണക്ഷനുകൾ പരിശോധിക്കുക: Double-check all wiring before applying power to the circuit.

ചിത്രം 3: പിൻഭാഗം view of the uxcell 91C4 DC 0-10V Analog Panel Voltmeter, illustrating the terminal posts and the included mounting hardware. This hardware, consisting of nuts, washers, and screws, is used to secure the meter firmly to a panel.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed and wired correctly, operating the uxcell 91C4 voltage gauge is straightforward:
- പവർ പ്രയോഗിക്കുക: Turn on the power supply to the DC circuit being monitored.
- അളവ് വായിക്കുക: The meter's needle will move across the scale to indicate the current DC voltage. Read the value directly from the scale.
- Observe Range: Ensure the needle remains within the 0-10V range. Continuous operation above the maximum rated voltage may damage the meter.

ചിത്രം 4: ക്ലോസ് അപ്പ് view of the meter's face, emphasizing the clear voltage scale, the red needle, and the model markings. This detailed view assists users in accurately reading the measured voltage.
7. പരിപാലനം
The uxcell 91C4 voltage gauge requires minimal maintenance:
- വൃത്തിയാക്കൽ: Wipe the meter's front panel with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- പരിശോധന: Periodically check the wiring connections for tightness and signs of corrosion.
- പരിസ്ഥിതി: Ensure the operating environment remains within suitable conditions (e.g., avoid extreme temperatures or humidity).
8. പ്രശ്നപരിഹാരം
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Meter needle does not move. | No power to the circuit; incorrect wiring; meter malfunction. | Verify power supply; check wiring for correct polarity and secure connections; if issues persist, meter may be faulty. |
| Meter needle shows incorrect reading. | Incorrect wiring; meter calibration issue; external interference. | Recheck wiring; ensure the measured voltage is within the meter's range; if possible, compare with a known accurate voltmeter. |
| Meter needle is stuck or erratic. | Physical damage; internal component failure. | Inspect for visible damage; if internal, meter may need replacement. |
If troubleshooting steps do not resolve the issue, contact uxcell customer support.
9. വാറൻ്റിയും പിന്തുണയും
For warranty information and technical support, please refer to the uxcell official webസൈറ്റിൽ ബന്ധപ്പെടുകയോ അവരുടെ ഉപഭോക്തൃ സേവന വിഭാഗവുമായി ബന്ധപ്പെടുകയോ ചെയ്യുക. വാറന്റി ക്ലെയിമുകൾക്കായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ:
- സന്ദർശിക്കുക uxcell Store on Amazon ഉൽപ്പന്ന വിവരങ്ങൾക്കും പിന്തുണയ്ക്കും.
- Refer to your product packaging or uxcell's official webനിർദ്ദിഷ്ട വാറന്റി നിബന്ധനകൾക്കും ബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങൾക്കും സൈറ്റ്.