1. ഉൽപ്പന്നം കഴിഞ്ഞുview
The CONTEC CMS 5100 is a compact patient monitor designed for measuring SpO2 (blood oxygen saturation) and NIBP (non-invasive blood pressure). This device is intended for use by trained personnel for continuous or spot-check monitoring of adult, pediatric, and neonatal patients in various clinical settings. It features a clear display for vital signs and an intuitive interface for ease of use.

ചിത്രം 1.1: The CONTEC CMS 5100 Patient Monitor shown with its included accessories, including the NIBP cuff, SpO2 probe, power adapter, and connecting cables.
2 സുരക്ഷാ വിവരങ്ങൾ
Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in inaccurate readings, device damage, or injury.
- This device is for medical use only and should be operated by trained professionals or under their supervision.
- Do not use the monitor in the presence of flammable anesthetics or other flammable substances.
- Ensure all cables and sensors are securely connected before use.
- Regularly inspect the device and accessories for any signs of damage. Do not use if damaged.
- ശക്തമായ വൈദ്യുതകാന്തിക മണ്ഡലങ്ങളിൽ നിന്ന് ഉപകരണം അകറ്റി നിർത്തുക.
- പ്രാദേശിക നിയന്ത്രണങ്ങൾ അനുസരിച്ച് ബാറ്ററികളും ഉപകരണവും നശിപ്പിക്കുക.
3. പാക്കേജ് ഉള്ളടക്കം
Verify that all items listed below are present in the package upon unboxing:
- CONTEC CMS 5100 Patient Monitor Unit
- NIBP Cuff (Adult size, typically)
- SpO2 Probe
- NIBP Extension Tube
- പവർ അഡാപ്റ്റർ
- പവർ കോർഡ്
- ഉപയോക്തൃ മാനുവൽ (ഈ പ്രമാണം)
- Lithium Polymer Battery (pre-installed or included separately)
4. സജ്ജീകരണം
4.1. പവർ കണക്ഷൻ
The monitor can be powered by the included AC adapter or its internal rechargeable Lithium Polymer battery.
- പവർ കോർഡ് എസി അഡാപ്റ്ററിലേക്ക് ബന്ധിപ്പിക്കുക.
- Plug the AC adapter into the power input port on the back of the monitor.
- ഒരു സാധാരണ ഇലക്ട്രിക്കൽ ഔട്ട്ലെറ്റിലേക്ക് പവർ കോർഡ് പ്ലഗ് ചെയ്യുക.
- The monitor will begin charging the internal battery. A full charge provides approximately 6 hours of operation.

ചിത്രം 4.1: പിൻഭാഗം view of the monitor, highlighting the power input port for connecting the AC adapter.
4.2. സെൻസർ കണക്ഷൻ
Proper connection of sensors is crucial for accurate measurements.
- NIBP Cuff: Connect the NIBP extension tube to the NIBP port on the side of the monitor. Then, connect the NIBP cuff to the other end of the extension tube. Ensure a secure, airtight connection.
- SpO2 Probe: Connect the SpO2 probe cable to the dedicated SpO2 port on the side of the monitor. Ensure the connector is fully inserted.

ചിത്രം 4.2: ക്ലോസ് അപ്പ് view of the sensor connection ports on the side of the monitor, including the NIBP and SpO2 ports.

ചിത്രം 4.3: വശം view of the monitor, illustrating the location of the control buttons and sensor connection ports.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
5.1. പവർ ഓൺ/ഓഫ്
- പവർ ഓണാക്കാൻ: Press and hold the power button (usually located on the front or side) until the display illuminates.
- പവർ ഓഫ് ചെയ്യാൻ: Press and hold the power button until the device shuts down. Confirm any shutdown prompts if they appear.
5.2. NIBP Measurement
- Apply the NIBP cuff to the patient's arm, ensuring it is snug but not overly tight, and positioned correctly over the brachial artery.
- Select the appropriate patient mode (Adult, Pediatric, Neonatal) if available.
- Press the NIBP START/STOP button to initiate a blood pressure measurement. The cuff will inflate and then slowly deflate.
- The systolic, diastolic, and mean arterial pressure (MAP) values will be displayed on the screen once the measurement is complete.
5.3. SpO2 Measurement
- Attach the SpO2 probe to the patient's finger (or appropriate site for pediatric/neonatal patients). Ensure the probe is securely placed and the light emitter/detector are aligned.
- The monitor will automatically begin displaying SpO2 percentage and pulse rate (PR) once a stable signal is detected.
- Observe the plethysmograph waveform on the display for signal quality.
5.4. വിവരങ്ങൾ പ്രദർശിപ്പിക്കുക
The monitor's display provides real-time vital sign data and device status.

ചിത്രം 5.1: The monitor's display showing numerical values for NIBP (SYS, DIA, MAP), SpO2, and PR, along with a plethysmograph waveform.
- NIBP: Displays Systolic (SYS), Diastolic (DIA), and Mean Arterial Pressure (MAP) in mmHg.
- SpO2: Shows blood oxygen saturation percentage.
- PR: Indicates Pulse Rate in beats per minute (bpm).
- തരംഗരൂപം: A graphical representation of the SpO2 signal (plethysmograph).
- ബാറ്ററി സൂചകം: നിലവിലെ ബാറ്ററി ലെവൽ കാണിക്കുന്നു.
6. പരിപാലനം
6.1. വൃത്തിയാക്കൽ
- Wipe the monitor's exterior with a soft cloth dampened with a mild detergent or medical-grade disinfectant.
- ഉപകരണം ദ്രാവകത്തിൽ മുക്കരുത്.
- Clean sensors (NIBP cuff, SpO2 probe) according to their specific cleaning instructions to prevent cross-contamination.
6.2. ബാറ്ററി പരിചരണം
- Recharge the Lithium Polymer battery regularly to maintain its lifespan.
- If the device will not be used for an extended period, store it with a partial charge (around 50%) and recharge every few months.
- Replace the battery if its capacity significantly diminishes.
6.3. സംഭരണം
- Store the monitor and accessories in a clean, dry environment, away from direct sunlight and extreme temperatures.
- Keep the device protected from dust and moisture.
7. പ്രശ്നപരിഹാരം
പൊതുവായ പ്രശ്നങ്ങളും അവയുടെ സാധ്യമായ പരിഹാരങ്ങളും അറിയാൻ താഴെ കൊടുത്തിരിക്കുന്ന പട്ടിക കാണുക.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| മോണിറ്റർ പവർ ഓണാക്കുന്നില്ല. | ബാറ്ററി ചാർജ് കുറവാണ് അല്ലെങ്കിൽ പവർ കണക്ഷൻ ഇല്ല. | Connect the AC adapter and ensure it is plugged into a working outlet. Allow battery to charge. |
| NIBP measurement fails or is inconsistent. | Cuff improperly applied, tube kinked, or patient movement. | Re-apply cuff correctly, check tube for obstructions, ensure patient is still. |
| SpO2 readings are unstable or absent. | Probe improperly placed, patient movement, or poor perfusion. | Re-position the SpO2 probe, minimize patient movement, ensure adequate blood flow to the measurement site. |
| ഡിസ്പ്ലേ മങ്ങിയതോ പ്രതികരിക്കാത്തതോ ആണ്. | കുറഞ്ഞ ബാറ്ററി അല്ലെങ്കിൽ ഉപകരണത്തിന്റെ തകരാറ്. | ബാറ്ററി ചാർജ് ചെയ്യുക. പ്രശ്നം നിലനിൽക്കുകയാണെങ്കിൽ, ഉപഭോക്തൃ പിന്തുണയുമായി ബന്ധപ്പെടുക. |
8 സ്പെസിഫിക്കേഷനുകൾ
Key technical specifications for the CONTEC CMS 5100 Patient Monitor:
- ബ്രാൻഡ്: CONTEC
- മോഡൽ നമ്പർ: CMS 5100
- നിറം: വെള്ള
- ഇനത്തിൻ്റെ ഭാരം: 1 കിലോ 350 ഗ്രാം
- പാക്കേജ് അളവുകൾ: 30 x 29.5 x 23.5 സെ.മീ
- ബാറ്ററികൾ: 1 ലിഥിയം പോളിമർ ബാറ്ററി ആവശ്യമാണ് (ഉൾപ്പെടുത്തിയിരിക്കുന്നു)
- ബാറ്ററി തരം: ലിഥിയം-അയൺ പോളിമർ
- ശരാശരി ബാറ്ററി ലൈഫ്: 6 മണിക്കൂർ
- ലിഥിയം ബാറ്ററി ഊർജ്ജ ഉള്ളടക്കം: 4.9 വാട്ട് മണിക്കൂർ
- ലിഥിയം ബാറ്ററി ഭാരം: 0.85 ഗ്രാം
9. വാറൻ്റിയും പിന്തുണയും
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your authorized CONTEC dealer or service center. Keep your purchase receipt as proof of purchase for warranty claims.