MEXTECH DT1503

MEXTECH DT1503 Digital Capacitance Meter User Manual

Model: DT1503 (MEX105)

1. ആമുഖം

വാങ്ങിയതിന് നന്ദി.asing the MEXTECH DT1503 Digital Capacitance Meter. This precision instrument is designed for accurate capacitance measurements across a wide range, suitable for laboratory, factory, and educational use. Please read this manual thoroughly before operating the device to ensure safe and correct usage.

പാക്കേജ് ഉള്ളടക്കം:

MEXTECH DT1503 Digital Capacitance Meter package contents including meter, test leads, 9V battery, and user manual.
Figure 1: MEXTECH DT1503 package contents.

The image above shows the MEXTECH DT1503 Digital Capacitance Meter along with its included accessories: a set of test leads, a 9V battery, and the user manual.

2 സുരക്ഷാ വിവരങ്ങൾ

WARNING: To avoid electrical shock, do not operate the meter with the battery cover open.

CAUTION: This device complies with IEC61010-1 standards, rated for 1000V CAT II and 600V CAT III, Pollution Degree 2. Always adhere to safety guidelines.

തിരികെ view of the MEXTECH DT1503 Digital Capacitance Meter showing safety warnings and battery compartment.
ചിത്രം 2: പിൻഭാഗം view of the meter with safety markings.

The image displays the back of the MEXTECH DT1503 meter, highlighting important safety warnings and compliance information printed on the battery compartment cover.

3. ഉൽപ്പന്ന സവിശേഷതകൾ

The MEXTECH DT1503 Digital Capacitance Meter offers the following key features:

ഫ്രണ്ട് view of the MEXTECH DT1503 Digital Capacitance Meter showing its display, rotary switch, and buttons.
ചിത്രം 3: മുൻഭാഗം view of the MEXTECH DT1503 meter.

ഈ ചിത്രം വ്യക്തമായ ഒരു ആശയം നൽകുന്നു view of the meter's front panel, including the LCD display, rotary function switch, 'LIGHT' and 'HOLD' buttons, and the 'ADJ' knob for zero adjustment.

4. സജ്ജീകരണം

4.1 ബാറ്ററി ഇൻസ്റ്റാളേഷൻ

  1. Ensure the meter is turned OFF by rotating the function switch to the 'OFF' position.
  2. മീറ്ററിന്റെ പിൻഭാഗത്ത് ബാറ്ററി കമ്പാർട്ട്മെന്റ് കണ്ടെത്തുക.
  3. Open the battery cover by sliding or unscrewing it (refer to Figure 2).
  4. Insert one 9V battery, observing the correct polarity (+ and - terminals).
  5. ബാറ്ററി കവർ സുരക്ഷിതമായി അടയ്ക്കുക.

4.2 ടെസ്റ്റ് ലീഡുകൾ ബന്ധിപ്പിക്കുന്നു

  1. Insert the red test lead plug into the 'CX+' input terminal.
  2. Insert the black test lead plug into the 'COM' input terminal.
ഫ്രണ്ട് view of MEXTECH DT1503 Digital Capacitance Meter with red and black test leads connected to the CX+ and COM terminals.
Figure 4: Test leads connected to the meter.

This image shows the MEXTECH DT1503 meter with the red test lead connected to the 'CX+' terminal and the black test lead connected to the 'COM' terminal, ready for measurement.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1 പവർ ഓൺ/ഓഫ്

To turn the meter ON, rotate the rotary function switch from the 'OFF' position to any desired measurement range. To turn the meter OFF, rotate the switch back to the 'OFF' position.

5.2 സീറോ അഡ്ജസ്റ്റ്മെൻ്റ്

Before performing any capacitance measurement, especially on lower ranges, it is crucial to perform a zero adjustment to eliminate stray capacitance from the test leads and internal circuitry.

  1. Ensure the test leads are connected to the meter.
  2. Short the tips of the red and black test leads together.
  3. Rotate the 'ADJ' knob (located on the left side of the meter) until the display reads '000'.
  4. This adjustment should be performed for each range if significant deviation from zero is observed.

5.3 ശേഷി അളക്കൽ

  1. ഡിസ്ചാർജ് കപ്പാസിറ്റർ: Always ensure the capacitor to be measured is fully discharged before connecting it to the meter. Failure to do so can damage the meter or cause injury.
  2. ശ്രേണി തിരഞ്ഞെടുക്കുക: Rotate the function switch to the appropriate measurement range. If the capacitance value is unknown, start with the highest range (20mF) and work downwards until a stable and accurate reading is obtained.
  3. Connect Capacitor: Connect the test leads to the capacitor terminals. For polarized capacitors (e.g., electrolytic), connect the red lead to the positive terminal and the black lead to the negative terminal. For non-polarized capacitors, the connection order does not matter.
  4. Read Value: The capacitance value will be displayed on the LCD screen in the selected unit (pF, nF, µF, or mF).

5.4 ഡാറ്റ ഹോൾഡ് പ്രവർത്തനം

To freeze the current reading on the display, press the 'HOLD' button. The 'HOLD' indicator will appear on the screen. Press the 'HOLD' button again to release the reading and resume live measurement.

5.5 ബാക്ക്‌ലൈറ്റ്

Press the 'LIGHT' button to activate the display backlight. This feature is useful for reading measurements in low-light conditions. The backlight will automatically turn off after approximately 10 seconds to conserve battery power.

6. Measurement Ranges and Accuracy

The MEXTECH DT1503 offers the following measurement ranges and typical accuracy specifications:

പരിധികൃത്യതറെസലൂഷൻ
200pF± 0.5% + 20 അക്കങ്ങൾ0.1pF
2nF± 0.5% + 20 അക്കങ്ങൾ1pF
20nF± 0.5% + 20 അക്കങ്ങൾ10pF
200nF± 0.5% + 20 അക്കങ്ങൾ100pF
2µF± 0.5% + 20 അക്കങ്ങൾ1nF
20µF± 0.5% + 20 അക്കങ്ങൾ10nF
200µF± 0.5% + 20 അക്കങ്ങൾ100nF
2 മി± 2% + 20 അക്കങ്ങൾ1µF
20 മി± 2% + 20 അക്കങ്ങൾ10µF

7. പരിപാലനം

7.1 വൃത്തിയാക്കൽ

To clean the meter, wipe the casing with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the plastic components or electronic circuits.

7.2 ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ

When the low battery indicator appears on the display, the 9V battery needs to be replaced. Follow the steps outlined in Section 4.1 'Battery Installation'. Ensure the meter is OFF before replacing the battery.

7.3 ഫ്യൂസ് മാറ്റിസ്ഥാപിക്കൽ

If the meter fails to function or provides incorrect readings consistently, the internal fuse may need replacement. Fuse replacement should only be performed by a qualified technician to ensure the correct fuse type and rating are used. Opening the meter by unauthorized personnel may void the warranty.

8. പ്രശ്‌നപരിഹാരം

This section addresses common issues you might encounter with your MEXTECH DT1503 meter.

9 സ്പെസിഫിക്കേഷനുകൾ

പരാമീറ്റർസ്പെസിഫിക്കേഷൻ
പ്രദർശിപ്പിക്കുക3½ Digit LCD, 1999 counts
വൈദ്യുതി വിതരണം9V battery (NEDA 1604 or 6F22 type)
പ്രവർത്തന താപനില0°C മുതൽ 40°C വരെ (32°F മുതൽ 104°F വരെ)
സംഭരണ ​​താപനില-10°C മുതൽ 50°C വരെ (14°F മുതൽ 122°F വരെ)
അളവുകൾ (L x W x H)185 x 90 x 53 മിമി
ഭാരംഏകദേശം 380 ഗ്രാം (ബാറ്ററി ഉൾപ്പെടെ)
മോഡൽ നമ്പർMEX105 (also known as DT1503)
സുരക്ഷാ റേറ്റിംഗ്IEC61010-1, CAT II 1000V, CAT III 600V, Pollution Degree 2

10. വാറൻ്റിയും പിന്തുണയും

For warranty information, technical assistance, or service inquiries regarding your MEXTECH DT1503 Digital Capacitance Meter, please refer to the warranty card included with your product or visit the official MEXTECH webബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങൾക്കും പിന്തുണാ ഉറവിടങ്ങൾക്കുമുള്ള സൈറ്റ്.

അനുബന്ധ രേഖകൾ - DT1503

പ്രീview MEXTECH Digital Dual Display TRMS Clamp മീറ്റർ പ്രവർത്തന മാനുവൽ
Comprehensive operation manual for the MEXTECH Digital Dual Display TRMS Clamp Meter (DT-3600), detailing safety precautions, component identification, technical specifications, and step-by-step operating instructions for various electrical measurements.
പ്രീview മെക്‌സ്‌ടെക് FG3006 ഫംഗ്ഷൻ ജനറേറ്റർ - ഉയർന്ന പ്രകടനമുള്ള സിഗ്നൽ ജനറേഷൻ
മെക്‌സ്‌ടെക് FG3006 പര്യവേക്ഷണം ചെയ്യുക, പോർട്ടബിൾ, ചെലവ് കുറഞ്ഞ, മൾട്ടി-ഫങ്ഷണൽ സിംഗിൾ-ചാനൽ സിഗ്നൽ ജനറേറ്റർ. DDS സാങ്കേതികവിദ്യ, 2.4 ഇഞ്ച് കളർ ഡിസ്‌പ്ലേ, 5MHz സൈൻ വേവ് ഔട്ട്‌പുട്ട്, വിവിധ തരംഗരൂപങ്ങൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. സ്പെസിഫിക്കേഷനുകൾ, ആപ്ലിക്കേഷനുകൾ, ആക്‌സസറികൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview MEXTECH DT-369 Digital True RMS Clamp മീറ്റർ ഉപയോക്തൃ മാനുവൽ
User manual for the MEXTECH DT-369 Digital True RMS Clamp Meter, covering features, specifications, safety instructions, and operation.
പ്രീview MEXTECH Digital Manometer MM45A - Pressure Measurement Tool
വിശദമായി പറഞ്ഞുview of the MEXTECH Digital Manometer MM45A, featuring its applications, key features, technical specifications, and accessories for precise air and gas pressure measurement.
പ്രീview Mextech Digital Manometer MM45B 5PSI - Technical Specifications and Features
Detailed information on the Mextech Digital Manometer MM45B, including its applications, features, and specifications for measuring air pressure in various systems.
പ്രീview Manometer User Manual - MM45C Model - MEXTECH
User manual for the MEXTECH MM45C Manometer, detailing its features, specifications, product description, and operational instructions for measuring air and differential pressure.