This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic Electronic Timer, Model ET2105CR. This electronic timer is designed for precise control of electrical loads, offering 24-hour and 365-day operation modes. It features a single channel with SPST contact form, capable of handling 30 Amps at 120 to 277Vac voltage.

Intermatic Electronic Timer in a gray metal enclosure

Figure 1: Intermatic Electronic Timer, Model ET2105CR, enclosed in a durable gray metal casing.

The timer is housed in a NEMA 3R rated metal enclosure, suitable for outdoor use, and includes a capacitor backup for up to 100 hours of operation during power outages. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of the device.

2 സുരക്ഷാ വിവരങ്ങൾ

Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons:

  • മുന്നറിയിപ്പ്: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse before installing or servicing.
  • എല്ലാ പ്രാദേശിക, ദേശീയ ഇലക്ട്രിക്കൽ കോഡുകൾക്കും അനുസൃതമായി യോഗ്യതയുള്ള ഒരു ഇലക്ട്രീഷ്യൻ ഇൻസ്റ്റാളേഷനും വയറിംഗും നടത്തണം.
  • Do not exceed the maximum electrical ratings of the device (30 Amps, 120-277Vac).
  • വൈദ്യുതാഘാതം തടയാൻ ശരിയായ ഗ്രൗണ്ടിംഗ് ഉറപ്പാക്കുക.
  • Do not use this device for applications where failure could result in dangerous conditions (e.g., medical life support equipment).
  • Keep the enclosure door closed and secured to maintain NEMA 3R rating and protect internal components.

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

3.1 Mounting the Timer

The ET2105CR timer is designed for surface mounting. Choose a suitable location that is accessible for wiring and programming, and protected from direct physical damage. Ensure the mounting surface is stable and can support the weight of the timer.

  1. Open the timer enclosure door.
  2. Locate the mounting holes on the back of the enclosure.
  3. Using appropriate screws and anchors (not supplied), securely fasten the timer to the desired surface.
  4. Ensure the timer is level and firmly attached.

3.2 വയറിംഗ് നിർദ്ദേശങ്ങൾ

All wiring must comply with the National Electrical Code (NEC) and local codes. Refer to the wiring diagram inside the timer enclosure for specific connections.

  1. ENSURE POWER IS DISCONNECTED AT THE SOURCE BEFORE WIRING.
  2. Route the incoming power supply wires (LINE) and the load wires (LOAD) into the timer enclosure through appropriate conduit openings.
  3. Connect the LINE wires to the designated LINE terminals on the timer.
  4. Connect the LOAD wires to the designated LOAD terminals on the timer.
  5. Connect the ground wire to the ground terminal within the enclosure.
  6. എല്ലാ കണക്ഷനുകളുടെയും ഇറുകിയതും ശരിയായ പോളാരിറ്റിയും രണ്ടുതവണ പരിശോധിക്കുക.
  7. എൻക്ലോഷർ വാതിൽ അടച്ച് സുരക്ഷിതമാക്കുക.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

4.1 Initial Power-Up and Display

Once wired and power is restored, the timer's display (1" height, 3" width) will illuminate. The internal capacitor will begin charging, providing backup power for settings retention during power outages.

4.2 നിലവിലെ സമയവും തീയതിയും ക്രമീകരിക്കുന്നു

Before programming ON/OFF events, set the current time and date accurately.

  1. Press the "MENU" button to access the main menu.
  2. Navigate to "SET TIME/DATE" using the arrow buttons.
  3. Press "ENTER" to confirm.
  4. Adjust the year, month, day, hour, and minute using the arrow buttons and confirm each setting with "ENTER".

4.3 Programming ON/OFF Events

The timer supports up to 96 ON/OFF cycles. Each event can be programmed for specific days of the week or daily operation.

  1. From the main menu, navigate to "PROGRAM EVENTS".
  2. Select "ADD NEW EVENT".
  3. Choose "ON" or "OFF" for the event type.
  4. Set the desired time (hour and minute) for the event.
  5. Select the days of the week for the event to be active (e.g., Mon-Fri, Daily, or specific days).
  6. Confirm the event. Repeat for all desired ON and OFF cycles.

4.4 മാനുവൽ അസാധുവാക്കൽ

The timer allows for temporary manual override of programmed events.

  • Press the "MANUAL" button to toggle the output state (ON/OFF) without affecting the programmed schedule.
  • The timer will revert to the programmed schedule at the next scheduled event.

5. പരിപാലനം

The Intermatic Electronic Timer is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

  • മുന്നറിയിപ്പ്: ഏതെങ്കിലും അറ്റകുറ്റപ്പണികൾ നടത്തുന്നതിന് മുമ്പ് വൈദ്യുതി വിച്ഛേദിക്കുക.
  • വൃത്തിയാക്കൽ: Periodically wipe the exterior of the enclosure with a soft, damp തുണി. ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
  • പരിശോധന: Annually inspect the wiring connections for tightness and signs of corrosion or damage. Ensure the enclosure door seal is intact to maintain its NEMA 3R rating.
  • ബാറ്ററി ബാക്കപ്പ്: The internal capacitor provides backup for settings. If the timer frequently loses its settings after power outages, the capacitor may need servicing by a qualified technician.

6. പ്രശ്‌നപരിഹാരം

പൊതുവായ പ്രശ്നങ്ങളും അവയുടെ പരിഹാരങ്ങളും അറിയാൻ താഴെയുള്ള പട്ടിക കാണുക.

പ്രശ്നം സാധ്യമായ കാരണം പരിഹാരം
ടൈമർ ഡിസ്പ്ലേ ശൂന്യമാണ്. ടൈമറിന് പവർ ഇല്ല. Check circuit breaker/fuse. Verify wiring connections.
Timer does not switch load ON/OFF as programmed. Incorrect programming; Manual override active; Wiring issue. Review programmed events. Check if manual override is engaged. Verify load wiring.
Timer loses settings after power outage. Capacitor backup not fully charged or failing. Allow timer to remain powered for 24 hours to fully charge capacitor. If issue persists, contact qualified service personnel.
Enclosure shows signs of water ingress. Damaged enclosure seal or improper installation. Inspect enclosure for cracks or damage. Ensure door is properly latched and seal is intact. Re-seal or replace if necessary.

7 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർ വിശദാംശങ്ങൾ
മോഡൽ നമ്പർ ET2105CR
ഓപ്പറേഷൻ മോഡ് 24 മണിക്കൂർ / 365 ദിവസം
ചാനലുകളുടെ എണ്ണം 1
ബന്ധപ്പെടാനുള്ള ഫോം എസ്.പി.എസ്.ടി
വാല്യംtage 120 മുതൽ 277Vac വരെ
Ampഉന്മേഷം 30 Amps
Max. ON/OFF Cycles 96
എൻക്ലോഷർ Metal, NEMA 3R Rated
മൗണ്ടിംഗ് ഉപരിതലം
Min. Time Setting 1 മിനിറ്റ്
പരമാവധി. സമയ ക്രമീകരണം 24 മണിക്കൂർ
ബാക്കപ്പ് ഉപകരണം കപ്പാസിറ്റർ
ബാക്കപ്പ് സമയം 100 മണിക്കൂർ
പ്രവർത്തന താപനില -40°F മുതൽ 155°F വരെ (-40°C മുതൽ 68°C വരെ)
ഡിസ്പ്ലേ അളവുകൾ 1" Height x 3" Width
ഉൽപ്പന്ന അളവുകൾ (H x W x D) 10-1/8" x 6-1/2" x 3-5/8" (10.13" x 6.5" x 3.63")
ഭാരം 3.32 പൗണ്ട്
മാനദണ്ഡങ്ങൾ UL Listed, California Title 20 Listed, LED Listed
യു.പി.സി 078275147966
Intermatic Electronic Timer with dimensions labeled: 10.12 inches height, 6.5 inches width, 3.62 inches depth.

Figure 2: Dimensions of the Intermatic Electronic Timer, Model ET2105CR.

8. വാറൻ്റിയും പിന്തുണയും

8.1 വാറൻ്റി വിവരങ്ങൾ

Intermatic products are manufactured under strict quality standards. For specific warranty terms and conditions applicable to your ET2105CR Electronic Timer, please refer to the warranty card included with your product or visit the official Intermatic website. Warranty coverage typically includes defects in material and workmanship for a specified period from the date of purchase.

8.2 സാങ്കേതിക പിന്തുണ

If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact Intermatic Customer Support. Have your model number (ET2105CR) and purchase information ready when contacting support.

For the most current contact information, please visit the official Intermatic webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ ഉൽപ്പന്നത്തിന്റെ പാക്കേജിംഗ് കാണുക.

Note: Protection plans offered by third-party sellers are separate from the manufacturer's warranty.

അനുബന്ധ രേഖകൾ - ET2105CR

പ്രീview ഇന്റർമാറ്റിക് HB880R ഔട്ട്‌ഡോർ 7-ദിവസ ഡിജിറ്റൽ ടൈമർ: പ്രവർത്തന നിർദ്ദേശങ്ങളും സജ്ജീകരണ ഗൈഡും
ഇന്റർമാറ്റിക് HB880R ഔട്ട്‌ഡോർ 7-ദിവസ ഡിജിറ്റൽ ടൈമറിനായുള്ള സമഗ്ര ഉപയോക്തൃ മാനുവൽ. ഈ വൈവിധ്യമാർന്ന സമയ സ്വിച്ച് എങ്ങനെ ഇൻസ്റ്റാൾ ചെയ്യാമെന്നും, പ്രോഗ്രാം ചെയ്യാമെന്നും, ഷെഡ്യൂളുകൾ സജ്ജീകരിക്കാമെന്നും, ട്രബിൾഷൂട്ട് ചെയ്യാമെന്നും അറിയുക.
പ്രീview ഇന്റർമാറ്റിക് EI200 ഇലക്ട്രോണിക് ഇൻ-വാൾ കൗണ്ട്ഡൗൺ ടൈമർ ഇൻസ്റ്റാളേഷനും ഓപ്പറേഷൻ ഗൈഡും
ഇന്റർമാറ്റിക് EI200 ഇലക്ട്രോണിക് ഇൻ-വാൾ കൗണ്ട്‌ഡൗൺ ടൈമർ ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനും പ്രവർത്തിപ്പിക്കുന്നതിനുമുള്ള വിശദമായ ഗൈഡ്. 5-30 മിനിറ്റ് സമയ ശ്രേണികൾ, തുടർച്ചയായ ഹോൾഡ് മോഡ്, 15A ജനറൽ പർപ്പസ്, 1000W ടങ്സ്റ്റൺ, 1/4 HP മോട്ടോറുകൾ എന്നിവയ്ക്കുള്ള റേറ്റിംഗുകൾ സവിശേഷതകളിൽ ഉൾപ്പെടുന്നു. വാറന്റി വിവരങ്ങൾ ഉൾപ്പെടുന്നു.
പ്രീview ഇന്റർമാറ്റിക് ET8215C ഇലക്ട്രോണിക് ടൈമർ നിയന്ത്രണം - സാങ്കേതിക ഡാറ്റ
ഇന്റർമാറ്റിക് ET8215C ഇലക്ട്രോണിക് ടൈമർ കൺട്രോളിനായുള്ള വിശദമായ സാങ്കേതിക സവിശേഷതകൾ, ഒരു ഇൻഡോർ മെറ്റൽ എൻക്ലോഷറിൽ 120-277 VAC ആപ്ലിക്കേഷനുകൾക്ക് അനുയോജ്യമായ ഒരു ജ്യോതിശാസ്ത്ര 7-ദിവസത്തെ, 2-സർക്യൂട്ട് ഇലക്ട്രോണിക് നിയന്ത്രണ സംവിധാനം.
പ്രീview ഇന്റർമാറ്റിക് EI210 ഇലക്ട്രോണിക് ഇൻ-വാൾ കൗണ്ട്ഡൗൺ ടൈമർ - ഇൻസ്റ്റലേഷൻ & ഓപ്പറേഷൻ ഗൈഡ്
ഇന്റർമാറ്റിക് EI210 ഇലക്ട്രോണിക് ഇൻ-വാൾ കൗണ്ട്‌ഡൗൺ ടൈമറിനായുള്ള സമഗ്ര ഗൈഡ്, വിശദമായ സവിശേഷതകൾ, ഇൻസ്റ്റാളേഷൻ ഘട്ടങ്ങൾ, പ്രവർത്തന മോഡുകൾ (ടൈമറും ഹോൾഡും), വാറന്റി വിവരങ്ങൾ എന്നിവയും ഇതിൽ ഉൾപ്പെടുന്നു. ഇന്റർമാറ്റിക് ഇൻകോർപ്പറേറ്റഡിന്റെ സാങ്കേതിക സവിശേഷതകളും ബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങളും ഉൾപ്പെടുന്നു.
പ്രീview Intermatic EI205 Electronic In-Wall Countdown Timer: Installation and Operation Guide
Comprehensive guide for installing and operating the Intermatic EI205 electronic in-wall countdown timer. Covers features, ratings, step-by-step installation, operation modes, and a 1-year limited warranty. Ideal for controlling lighting and loads with timed shut-off.
പ്രീview ഇന്റർമാറ്റിക് EJ351 ഇൻഡോർ വാൾ സ്വിച്ച് ടൈമർ: ഇൻസ്റ്റാളേഷനും ഉപയോക്തൃ നിർദ്ദേശങ്ങളും
ഇന്റർമാറ്റിക് EJ351 ഇൻഡോർ വാൾ സ്വിച്ച് ടൈമറിനായുള്ള ഇൻസ്റ്റാളേഷൻ, ഉപയോക്തൃ നിർദ്ദേശങ്ങൾ ഈ പ്രമാണം നൽകുന്നു. ഇതിൽ സ്പെസിഫിക്കേഷനുകൾ, വയറിംഗ്, പ്രോഗ്രാമിംഗ് രീതികൾ (റാപ്പിഡ്, 24-മണിക്കൂർ), ദൈനംദിന ഉപയോഗം, ട്രബിൾഷൂട്ടിംഗ്, ഒരു വർഷത്തെ പരിമിത വാറന്റി എന്നിവ ഉൾപ്പെടുന്നു.