APOLLO 69ELF114TWG

Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge Instruction Manual

Model: 69ELF114TWG

1. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge (Model 69ELF114TWG) is designed to reduce incoming water pressure to a safe and consistent level for residential and commercial plumbing systems. This unit features a compact design, lead-free bronze construction, and an integrated internal bypass mechanism. It includes a color-coded gauge for easy pressure monitoring and adjustment.

Apollo 3/4 inch Bronze Water Pressure Regulator with Gauge

Figure 1: Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge. This image shows the regulator with its integrated pressure gauge and yellow adjustment handle.

2 സുരക്ഷാ വിവരങ്ങൾ

3. പാക്കേജ് ഉള്ളടക്കം

ഇൻസ്റ്റാളേഷൻ ആരംഭിക്കുന്നതിന് മുമ്പ് എല്ലാ ഘടകങ്ങളും നിലവിലുണ്ടെന്ന് ഉറപ്പാക്കുക:

4. ഇൻസ്റ്റലേഷൻ

This regulator features a double union PEX-A (cold expansion) barb design for simplified installation in PEX-A piping systems. Ensure the regulator is installed in the correct flow direction, indicated by an arrow on the body.

  1. ഇൻസ്റ്റലേഷൻ സൈറ്റ് തയ്യാറാക്കുക: Turn off the main water supply. Drain the water lines to relieve pressure. Select a suitable location for the regulator, typically after the main shut-off valve and before any branch lines.
  2. Cut and Prepare PEX-A Piping: Cut the PEX-A pipe to the required length, ensuring clean, square cuts. Prepare the pipe ends for cold expansion connections according to PEX-A system manufacturer guidelines.
  3. റെഗുലേറ്റർ ബന്ധിപ്പിക്കുക:
    • Apply appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the PEX-A fittings.
    • Thread the PEX-A fittings onto the double union ends of the regulator. Ensure the flow arrow on the regulator body points in the direction of water flow into the building.
    • Tighten the union nuts securely, but do not overtighten.
    • Perform cold expansion connections on the PEX-A pipe ends to the fittings according to PEX-A system manufacturer instructions.
  4. പ്രഷർ ഗേജ് ഇൻസ്റ്റാൾ ചെയ്യുക: The pressure gauge is typically pre-installed. Ensure it is securely threaded into the designated port on the regulator body.
  5. Restore Water Supply and Check for Leaks: Slowly turn on the main water supply. Carefully inspect all connections for any signs of leaks. Tighten connections as necessary.
Apollo Water Pressure Regulator with PEX-A connections

ചിത്രം 2: വശം view of the Apollo Water Pressure Regulator, showing the double union PEX-A connections and the flow direction arrow. Note the "MAX INLET 400 PSI" marking.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The regulator is factory-set at 50 psi and is adjustable from 15 psi to 75 psi. No special tools are required for adjustment.

  1. നിലവിലെ മർദ്ദം പരിശോധിക്കുക: Observe the reading on the integrated pressure gauge. The gauge is color-coded to indicate pressure ranges (e.g., Low, Optimal, Excessive).
  2. സമ്മർദ്ദം ക്രമീകരിക്കൽ:
    • ലേക്ക് വർധിപ്പിക്കുക pressure: Turn the yellow adjustment handle ഘടികാരദിശയിൽ.
    • ലേക്ക് കുറയുന്നു pressure: Turn the yellow adjustment handle എതിർ ഘടികാരദിശയിൽ.
    • Make small adjustments and allow the system pressure to stabilize before re-checking the gauge.
  3. ക്രമീകരണം സ്ഥിരീകരിക്കുക: Once the desired pressure is achieved (typically between 50-60 psi for most residential applications), confirm the reading on the gauge.
Apollo Water Pressure Regulator with gauge showing optimal pressure range

ചിത്രം 3: ക്ലോസപ്പ് view of the Apollo Water Pressure Regulator, highlighting the pressure gauge with its color-coded optimal range and the yellow adjustment handle.

6. പരിപാലനം

The Apollo Water Pressure Regulator is designed for minimal maintenance. Regular checks can help ensure optimal performance.

7. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
No water flow or very low pressure downstreamRegulator set too low; Main water supply off; Regulator clogged.Increase pressure setting; Check main water valve; Inspect for debris (consult a plumber if necessary).
Pressure too high downstreamRegulator set too high; Regulator malfunction.Decrease pressure setting; If problem persists, regulator may need replacement.
Water hammer or fluctuating pressureRapid changes in water demand; Regulator bypass mechanism issue.Ensure proper air chambers are installed in the plumbing system; Consult a plumber for regulator inspection.
കണക്ഷനുകളിലെ ചോർച്ചകൾImproperly tightened connections; Insufficient thread sealant.Tighten connections; Reapply thread sealant if necessary (ensure water supply is off first).

8 സ്പെസിഫിക്കേഷനുകൾ

9. വാറൻ്റിയും പിന്തുണയും

This Apollo Water Pressure Regulator comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Apollo customer support.

For technical support or inquiries, please visit the official Apollo webസൈറ്റ് അല്ലെങ്കിൽ അവരുടെ ഉപഭോക്തൃ സേവന വിഭാഗവുമായി ബന്ധപ്പെടുക.

അനുബന്ധ രേഖകൾ - 69ELF114TWG

പ്രീview അപ്പോളോ എയർ ഇലക്ട്രിക് സ്കൂട്ടർ ഉപയോക്തൃ മാനുവൽ - സജ്ജീകരണം, പ്രവർത്തനം, സുരക്ഷ
അപ്പോളോ എയർ ഇലക്ട്രിക് സ്കൂട്ടറിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, സജ്ജീകരണം, പ്രവർത്തനം, സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ, അറ്റകുറ്റപ്പണികൾ, വാറന്റി വിവരങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്നു. നിങ്ങളുടെ അപ്പോളോ എയർ എങ്ങനെ സുരക്ഷിതമായി ആസ്വദിക്കാമെന്ന് മനസിലാക്കുക.
പ്രീview അപ്പോളോ ഗോ ഇലക്ട്രിക് സ്കൂട്ടർ യൂസർ മാനുവൽ
അപ്പോളോ ഗോ ഇലക്ട്രിക് സ്കൂട്ടറിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, സജ്ജീകരണം, പ്രവർത്തനം, അറ്റകുറ്റപ്പണികൾ, ട്രബിൾഷൂട്ടിംഗ്, സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview Apollo POWER VS Series Turbine Instruction Manual - HVLP Spraying Guide
Comprehensive instruction manual for the Apollo POWER VS Series HVLP Turbine Spray Systems. Learn about setup, operation, maintenance, and best practices for achieving professional spray finishing results.
പ്രീview അപ്പോളോ ഗോ ഇലക്ട്രിക് സ്കൂട്ടർ യൂസർ മാനുവൽ
അപ്പോളോ ഗോ ഇലക്ട്രിക് സ്കൂട്ടറിനായുള്ള സമഗ്രമായ നിർദ്ദേശങ്ങൾ ഈ ഉപയോക്തൃ മാനുവലിൽ അടങ്ങിയിരിക്കുന്നു, അൺബോക്സിംഗ്, അസംബ്ലി, ഓപ്പറേഷൻ, ചാർജിംഗ്, മെയിന്റനൻസ്, സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ, ട്രബിൾഷൂട്ടിംഗ്, വാറന്റി വിവരങ്ങൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. നിങ്ങളുടെ അപ്പോളോ ഗോ ഇലക്ട്രിക് സ്കൂട്ടർ എങ്ങനെ സജ്ജീകരിക്കാമെന്നും ഓടിക്കാമെന്നും പരിപാലിക്കാമെന്നും മനസ്സിലാക്കുക.
പ്രീview Apollo 23G Electric Fireplace Insert Assembly and User Manual
Comprehensive guide for assembling and operating the Apollo 23G electric fireplace insert, including safety instructions, parts identification, and troubleshooting tips for model HF190108/OLLIEFIR.
പ്രീview അപ്പോളോ SL15 ഓഡിയോ സെലക്ടർ പാനൽ ഇൻസ്റ്റലേഷൻ മാനുവൽ
This manual provides detailed installation and operation instructions for the Apollo SL15-series of Audio Selector Panel/Intercom Systems, including the SL15M with internal Marker Beacon. It covers general information, installation procedures, operation, and warranty.