1. ആമുഖം
This manual provides essential instructions for the safe and efficient operation of your WZRELB Pure Sine Wave 5000W 24V Power Inverter. This device converts 24V DC battery power into 120V AC household electricity, suitable for various applications including solar power systems and RVs. Please read this manual thoroughly before installation and use.

Image 1.1: WZRELB 5000W 24V Pure Sine Wave Power Inverter, front view showing AC outlets and DC input terminals.
2. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Proper installation is crucial for the safety and performance of your inverter. Follow these steps carefully:
- ബാറ്ററി കണക്ഷൻ: Connect the inverter to a 24V DC battery system. Ensure the battery is fully charged before installation.
- ധ്രുവത: ബന്ധിപ്പിക്കുക ചുവപ്പ് cable to the positive (+) terminal of the battery and the inverter. Connect the കറുപ്പ് cable to the negative (-) terminal of the battery and the inverter. Reverse connection of positive and negative terminals is strictly forbidden.
- കേബിളിംഗ്: Use the standard battery cables provided. For optimal performance and safety, ensure all connections are tightened securely. If using custom cables, ensure they are larger than AWG4. For cable lengths exceeding 24 inches, use thicker gauge cables to minimize voltage drop. If your inverter model includes 4 cables, use all of them to connect the inverter and battery to ensure full output.
- ബാറ്ററി ശേഷി: It is recommended to connect the inverter to a battery system with a capacity greater than 250AH for stable operation.
- ഫ്യൂസ് ഇൻസ്റ്റാളേഷൻ: ഒരു 250 ഇൻസ്റ്റാൾ ചെയ്യുക Amp fuse between the inverter and the battery for the 5000W 24V DC version to protect against overcurrent.
- ഗ്രിഡ് കണക്ഷൻ: Do not connect the inverter directly to grid power.

Image 2.1: Visual guide for inverter DC connection and terminal tightening. Ensure correct polarity and secure connections.
3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Follow these guidelines for safe and effective operation of your WZRELB inverter:
- പവർ-അപ്പ് സീക്വൻസ്: Turn on the inverter first using the ON/OFF switch. After the inverter is stable, then turn on your connected loads. This sequence is important due to the soft start function, which ensures stable output.
- Power-Down Sequence: Turn off all connected loads first, then turn off the inverter.
- ലോഡ് മാനേജ്മെന്റ്: Do not overload the inverter. The continuous power rating is 5000W, with a peak power of 10000W.
- ഇൻഡക്റ്റീവ് ലോഡുകൾ: For inductive loads (e.g., motors, compressors, refrigerators, microwaves, water pumps, air conditioners), the starting power can be significantly higher than the rated power. Choose an inverter with a continuous power rating 3-7 times higher than the appliance's rated power. For refrigerators, a power inverter 10 times higher than the appliance's rated power is recommended.
- കൂളിംഗ് ഫാൻ: The intelligent cooling fan operates based on temperature, not load. It will activate when the internal temperature exceeds 50°C (122°F) to maintain optimal operating temperature and prolong battery life.
- റിമോട്ട് കൺട്രോളർ: The remote controller requires a 23A 12V battery (not included due to transportation safety regulations). Purchase this battery locally if you intend to use the remote function.
4. പരിപാലനം
To ensure the longevity and optimal performance of your inverter, consider the following maintenance points:
- ശുചിത്വം: Keep the inverter clean and free from dust and debris. Regularly check the cooling fan vents to ensure they are not obstructed.
- കണക്ഷനുകൾ: Periodically inspect all electrical connections (DC input, AC output) for tightness and corrosion. Loose connections can lead to overheating and reduced efficiency.
- പരിസ്ഥിതി: Operate the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- ബാറ്ററി ആരോഗ്യം: Ensure your battery system is well-maintained and charged according to its manufacturer's specifications. A healthy battery system is vital for inverter performance.
5. പ്രശ്നപരിഹാരം
This section addresses common issues you might encounter with your WZRELB inverter:
| ലക്ഷണം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ഇൻവെർട്ടർ ഓണാകുന്നില്ല |
|
|
| Inverter shuts down during operation |
|
|
| ചുവന്ന വെളിച്ചം മിന്നിമറയുന്നു | ഇൻപുട്ട് വോളിയംtage അല്പം കൂടുതലാണ്. | ഇൻപുട്ട് വോളിയം നിരീക്ഷിക്കുകtage; ensure it stays within the acceptable range (21V-30V). |
| Output unstable at first seconds | Incorrect power-up sequence (loads turned on before inverter). | Always turn on the inverter first, then the loads. |
6 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| മോഡലിൻ്റെ പേര് | RBP-500024S |
| DC ഇൻപുട്ട് വോളിയംtage | 24V |
| DC ഇൻപുട്ട് ശ്രേണി | 21V-30V |
| എസി putട്ട്പുട്ട് വോളിയംtage | 120V |
| ആവൃത്തി | 60Hz |
| തുടർച്ചയായ ശക്തി | 5000W |
| പീക്ക് പവർ | 10000W |
| കാര്യക്ഷമത | 85%-90% |
| സോക്കറ്റുകൾ | Dual US Type |
| കുറഞ്ഞ വോളിയംtagഇ അലാറം | 19.5V-21.5V |
| കുറഞ്ഞ വോളിയംtagഇ ഷട്ട് ഡൗൺ | 18.5V-20.5V |
| ഓവർ വോളിയംtagഇ ഷട്ട് ഡൗൺ | 30.5V |
| തണുപ്പിക്കൽ രീതി | ഇന്റലിജന്റ് കൂളിംഗ് ഫാൻ (50°C യിൽ കൂടുതൽ സജീവമാക്കുന്നു) |
| ഉൽപ്പന്ന അളവുകൾ | 21.8 x 6.3 x 6.3 ഇഞ്ച് |
| ഇനത്തിൻ്റെ ഭാരം | 18.81 പൗണ്ട് |
| നിർമ്മാതാവ് | Yueqing Reliable Electric co.,ltd |
7. വാറൻ്റിയും പിന്തുണയും
WZRELB provides a 12 മാസ വാറൻ്റി for this product. For any inquiries, technical assistance, or warranty claims, please contact WZRELB customer service. We are committed to providing prompt and friendly support.