McKesson 06-005

McKesson Lancing Device User Manual

മോഡൽ: 06-005

1. ആമുഖം

The McKesson Lancing Device is designed for obtaining capillary blood samples for blood glucose testing. This device features multiple depth settings to accommodate various skin types and preferences, ensuring optimal skin penetration. It is a compact and portable tool intended for single patient use only.

McKesson Lancing Device and packaging

Image: The McKesson Lancing Device shown alongside its product packaging.

2 പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ

3. ഉൽപ്പന്ന സവിശേഷതകൾ

4. സജ്ജീകരണ നിർദ്ദേശങ്ങൾ

  1. കൈ കഴുകുക: Thoroughly wash your hands with soap and warm water, then dry them completely.
  2. തൊപ്പി നീക്കം ചെയ്യുക: Twist and pull off the adjustable depth cap from the lancing device.
  3. ലാൻസെറ്റ് ചേർക്കുക: Firmly insert a new, sterile McKesson Twist Lancet into the lancet holder until it clicks into place.
  4. Twist Off Lancet Cap: Carefully twist off the protective cap from the lancet and save it for safe disposal later.
  5. തൊപ്പി മാറ്റിസ്ഥാപിക്കുക: Replace the adjustable depth cap onto the lancing device.
  6. Select Depth Setting: Rotate the adjustable depth cap to your desired penetration depth. Start with a lower setting (e.g., 1 or 2) and adjust as needed to obtain a sufficient blood sample. Higher numbers indicate deeper penetration.
  7. Prime the Device: Pull back the cocking mechanism (plunger) until it clicks, indicating the device is primed and ready to fire.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

  1. Choose Lancing Site: Select a clean, dry area on your fingertip, preferably off-center. Avoid using the same spot repeatedly.
  2. സ്ഥാന ഉപകരണം: Place the lancing device firmly against the chosen lancing site.
  3. Activate Lancing: Press the release button to activate the lancet.
  4. രക്തം എസ് നേടുകampLe: Gently massage the lanced area to form a small drop of blood. Do not squeeze excessively.
  5. Apply to Test Strip: രക്തം പ്രയോഗിക്കുക എസ്ample to the designated area on your blood glucose test strip as per your meter's instructions.
  6. Remove Used Lancet: Carefully remove the adjustable depth cap. Place the protective cap (saved from setup) onto a flat surface and carefully push the exposed lancet needle into it. Eject the capped lancet by pushing the ejector button or sliding the ejector mechanism.
  7. Dispose of Lancet: Immediately dispose of the used, capped lancet in an approved sharps container.

6. പരിപാലനവും പരിചരണവും

7. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
രക്തമില്ല.ample obtained or insufficient sample.Depth setting too shallow; insufficient pressure on skin; dehydrated.Increase depth setting; apply more firm pressure; ensure adequate hydration.
Lancing device does not fire.Device not primed; lancet not inserted correctly.Pull back cocking mechanism until it clicks; ensure lancet is fully inserted.
Pain or discomfort during lancing.Depth setting too deep; using same site repeatedly; dull lancet.Decrease depth setting; rotate lancing sites; always use a new lancet.

8 സ്പെസിഫിക്കേഷനുകൾ

9. ഡിസ്പോസൽ

Proper disposal of used lancets and the lancing device is crucial to prevent injury and the spread of infection. Always dispose of used lancets in an FDA-cleared sharps disposal container immediately after use. When the lancing device itself needs to be disposed of (e.g., if damaged or at the end of its lifespan), consult your local waste management authority for guidelines on disposing of medical waste in your area.

10. വാറൻ്റിയും പിന്തുണയും

Specific warranty information for the McKesson Lancing Device is not provided in this manual. For warranty details, product support, or further assistance, please contact McKesson customer service directly or refer to the official McKesson website. Contact information can typically be found on the product packaging or the manufacturer's official webസൈറ്റ്.

അനുബന്ധ രേഖകൾ - 06-005

പ്രീview McKesson QUINTET AC Blood Glucose Meter - Features, Benefits, and Ordering
Information about the McKesson QUINTET AC Blood Glucose Meter, including its features, benefits, technical specifications, and ordering information. This meter is designed for both clinical and self-testing use.
പ്രീview McKesson ErgoCart Cleaning and Disinfection Instructions
Detailed cleaning and disinfection instructions for McKesson ErgoCart storage carts and mobile workstations, including recommended cleaning agents and processes.
പ്രീview McKesson Refrigerator/Freezer Thermometer TRIPLE DISPLAY SINGLE PROBE MCK821RFV
Detailed information and operating instructions for the McKesson Refrigerator/Freezer Thermometer, Triple Display, Single Probe (Model MCK821RFV). Features include high accuracy, min/max memory, alarm settings, and NIST traceability.
പ്രീview McKesson Digital Blood Pressure Monitor WRIST ADULT Owner's Manual
Owner's manual for the McKesson Digital Blood Pressure Monitor WRIST ADULT (MFR # 1990). Provides instructions on setup, operation, testing, maintenance, and troubleshooting.
പ്രീview McKesson Disposable Vaginal Specula: Instructions for Use and Product Information
Comprehensive guide to McKesson's disposable vaginal specula, covering usage instructions, cautions, indications, sterilization, and product specifications for medical professionals.
പ്രീview McKesson Wireless Refrigerator/Freezer Thermometer MCK895WRFT - Triple Display, Single Probe
User manual and specifications for the McKesson Wireless Refrigerator/Freezer Thermometer, model MCK895WRFT. Details features like triple display, single probe, large digit, wireless connectivity, alarm settings, and error codes.