1. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Weelko Hightech Professional Pressotherapy system is a digital device designed for professional use, featuring a touch screen display and four distinct working programs. This system is equipped with a comprehensive suit including boots, leggings, an abdominal band, and armrests, along with a cable blanket for organized storage. It is engineered to enhance circulation and aid in fat removal through lymphatic drainage activation.

Image 1.1: The Weelko Hightech Pressotherapy main unit with its various attachments, including leg, arm, and abdominal cuffs.
2 ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾ
The Weelko Hightech Pressotherapy system comes with the following components:
- പ്രധാന യൂണിറ്റ് (1)
- Right Leg Cuff (1)
- Left Leg Cuff (1)
- Right Arm Cuff (1)
- Left Arm Cuff (1)
- Right Foot Cuff (1)
- Left Foot Cuff (1)
- Abdominal Cuff (1)
- Cable Blanket (1)
- Tubes (1 set)
- പവർ കേബിൾ (1)

Image 2.1: The cable blanket provided for organizing and storing the system's tubes and cables.
3. സജ്ജീകരണ നിർദ്ദേശങ്ങൾ
Follow these steps to set up your pressotherapy system:
- പവർ ബന്ധിപ്പിക്കുക: Connect the power cable to the designated port on the rear panel of the main unit.
- Connect Tubes: Correctly connect the air tubes to the corresponding ports on the rear panel. Refer to the numerical instructions next to each port to ensure proper connection.
- Prepare Blanket: Place the cable blanket on a flat surface where the patient can comfortably lie down.
- Ensure Hygiene: Cover the blanket with disposable paper or a hygienic sheet to maintain optimal sanitary conditions for each use.
- Apply Suit: Carefully wrap the pressotherapy suit (composed of the chosen cuffs) around the user's body. Always ensure the user wears a disposable garment underneath the suit for hygiene.

Image 3.1: A user lying on the blanket with the pressotherapy suit applied, demonstrating proper setup for a session.
4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once the system is set up, follow these steps to operate the device:
- പവർ ഓൺ: Activate the power button located on the front panel of the main unit.
- ആക്സസ് മെനു: Click on the Weelko logo displayed on the touch screen to access the main menu and select desired settings.
- Select Program (MODE): Navigate to the "MODE" menu. This allows you to choose from four available programs. It is recommended to begin with program 'C' and then select other programs based on the patient's specific needs.
- Adjust Intensity (LEVEL): Use the "LEVEL" menu to set the inflation intensity. There are 3 levels of intensity available. Adjust using the '+' and '-' buttons.
- Set Treatment Time (TIME): Use the "TIME" menu to adjust the duration of the treatment. The default treatment duration is 30 minutes.
- Start/Pause Treatment: Press the "PLAY / PAUSE" button to initiate or temporarily halt the pressotherapy treatment.
5. പരിപാലനം
Proper maintenance ensures the longevity and optimal performance of your Weelko Pressotherapy system:
- വൃത്തിയാക്കൽ: After each use, wipe down the main unit and the exterior of the cuffs with a soft, damp cloth. Use a mild, non-abrasive disinfectant if necessary. Ensure all surfaces are dry before storage.
- Cuff Hygiene: Always use disposable liners or garments under the cuffs to maintain hygiene and prevent direct skin contact. Clean the interior of the cuffs periodically according to professional hygiene standards.
- സംഭരണം: Store the main unit and all components in a clean, dry place, away from direct sunlight and extreme temperatures. Utilize the provided cable blanket to neatly store tubes and cuffs.
- ട്യൂബ് പരിശോധന: Regularly inspect the air tubes for any kinks, cracks, or damage. Replace damaged tubes immediately to ensure proper air pressure and function.
- പ്രൊഫഷണൽ സേവനം: For any complex issues or routine professional checks, contact authorized Weelko service centers.
6. പ്രശ്നപരിഹാരം
If you encounter issues with your pressotherapy system, consider the following common solutions:
- ശക്തിയില്ല:
- പവർ കേബിൾ യൂണിറ്റിലേക്കും പ്രവർത്തിക്കുന്ന ഒരു പവർ ഔട്ട്ലെറ്റിലേക്കും സുരക്ഷിതമായി ബന്ധിപ്പിച്ചിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക.
- Check if the power switch on the unit is in the 'ON' position.
- മറ്റൊരു ഉപകരണം പ്ലഗ് ഇൻ ചെയ്ത് പവർ ഔട്ട്ലെറ്റ് പ്രവർത്തനക്ഷമമാണെന്ന് ഉറപ്പാക്കുക.
- Cuffs Not Inflating/Deflating Properly:
- Check all air tube connections to the main unit and to the cuffs. Ensure they are securely attached and not kinked.
- Inspect the tubes and cuffs for any visible damage or leaks.
- Verify that the selected program and intensity settings are appropriate.
- ടച്ച് സ്ക്രീൻ പ്രതികരിക്കുന്നില്ല:
- Try restarting the unit by turning it off and then on again.
- സ്ക്രീൻ വൃത്തിയുള്ളതും അവശിഷ്ടങ്ങളോ ഈർപ്പമോ ഇല്ലാത്തതുമാണെന്ന് ഉറപ്പാക്കുക.
- അസാധാരണമായ ശബ്ദങ്ങൾ:
- A slight humming sound during operation is normal. If you hear loud or unusual noises, turn off the unit immediately and contact customer support.
If the problem persists after attempting these solutions, please contact Weelko customer support for assistance.
7 സാങ്കേതിക സവിശേഷതകൾ
| വിഭാഗം | സ്പെസിഫിക്കേഷൻ |
|---|---|
| മോഡൽ നമ്പർ | 2418ef53-2aca-4897-b2c8-1fbe68f4aaf3 |
| പാക്കേജിംഗ് അളവുകൾ | 66 x 45 x 40 സെ.മീ |
| ആകെ ഭാരം | 18.5 കി.ഗ്രാം |
| ഉൽപ്പന്ന അളവുകൾ | 34 x 38 x 15 സെ.മീ |
| പ്രവർത്തന ശക്തി | 50 W |
| വായു മർദ്ദം | 0 - 0.4 kg/cm² |
| എയർ ഫ്ലോ | 0.40 എൽ/മിനിറ്റ് |
| Air Pressure Rhythm | 0 - 15 s |
| Air Channels | 10 (20 bags) |
| റേറ്റുചെയ്ത വോളിയംtage | 220 V ~ 240 V |
| ആവൃത്തി | 50Hz / 60Hz |
| റേറ്റുചെയ്ത പവർ | 50 W |
8. വാറൻ്റിയും പിന്തുണയും
For information regarding product warranty, returns, or technical support, please refer to the documentation provided with your purchase or contact Weelko customer service directly. Ensure you have your model number (2418ef53-2aca-4897-b2c8-1fbe68f4aaf3) and purchase details ready when contacting support.