Omnia 1130

Omnia Thermometer Model 1130 Instruction Manual

For use with the Omnia Oven

1. ആമുഖം

The Omnia Thermometer Model 1130 is designed to enhance your cooking experience with the Omnia Oven. This analog thermometer provides temperature readings to help you achieve optimal results when baking and cooking. It is specifically engineered for easy attachment to the Omnia Oven lid, allowing for convenient monitoring of internal oven temperatures or core food temperatures.

2 സുരക്ഷാ വിവരങ്ങൾ

Please read all safety instructions carefully before using the Omnia Thermometer.

  • Sharp Probe: The thermometer features a pointed probe. Exercise extreme caution during handling to prevent injury.
  • ഉയർന്ന താപനില: The thermometer and its probe will become very hot during and after use. Always use heat-resistant gloves or appropriate tools when handling the thermometer to avoid burns. Allow it to cool completely before cleaning or storing.
  • കുട്ടികൾ: Keep the Omnia Thermometer out of the reach of children at all times.
  • ഉദ്ദേശിച്ച ഉപയോഗം: This thermometer is designed exclusively for baking and cooking in the Omnia Oven. Do not use it for other purposes.
  • ലിഡ് അറ്റാച്ച്മെന്റ്: When attached to the Omnia Oven lid, the thermometer may alter the lid's weight distribution. Exercise caution when lifting or moving the lid to prevent accidental spills or drops.

3. പാക്കേജ് ഉള്ളടക്കം

അൺപാക്ക് ചെയ്യുമ്പോൾ എല്ലാ ഇനങ്ങളും ഉണ്ടെന്നും നല്ല നിലയിലാണെന്നും ഉറപ്പാക്കുക:

  • Omnia Thermometer (Sensor with Analog Display)
  • Practical Locking Mechanism
  • ഉപയോഗത്തിനുള്ള നിർദ്ദേശങ്ങൾ (ഈ മാനുവൽ)

4. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Omnia Thermometer features an analog display for easy temperature reading in both Celsius and Fahrenheit. Its robust design includes a pointed probe for accurate temperature measurement and a specialized locking mechanism for secure attachment.

ക്ലോസ് അപ്പ് view of the Omnia Thermometer's analog display, showing temperature scales in Celsius and Fahrenheit.

Figure 1: Omnia Thermometer Analog Display. The display shows temperature readings from 0°C/50°F to 300°C/500°F.

വശം view of the Omnia Thermometer, highlighting the pointed metal probe extending from the back of the unit.

Figure 2: Omnia Thermometer with Probe. The pointed probe is designed for insertion into food items.

പിൻഭാഗം view of the Omnia Thermometer, showing the adjustable locking mechanism used for attachment.

Figure 3: Omnia Thermometer Locking Mechanism. This mechanism secures the thermometer to the Omnia Oven lid.

5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

The Omnia Thermometer is designed for easy attachment to the Omnia Oven lid.

  1. Identify one of the existing holes on the Omnia Oven lid.
  2. Insert the thermometer's probe through the chosen hole from the outside of the lid.
  3. On the underside of the lid, use the practical locking mechanism to secure the thermometer firmly in place. Ensure it is stable and does not wobble.
Omnia Thermometer attached to the red lid of an Omnia Oven, showing its position for measuring oven temperature.

Figure 4: Thermometer Attached to Omnia Oven Lid. The thermometer is securely mounted on the lid.

കുറിപ്പ്: When the thermometer is attached to the lid, it measures the temperature in the upper part of the oven. This temperature may be higher than the core temperature of the food being cooked. For precise food core temperature, insert the probe directly into the food.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The Omnia Thermometer can be used in two primary ways:

6.1. Measuring Oven Temperature

  1. Attach the thermometer to the Omnia Oven lid as described in Section 5.
  2. Place the Omnia Oven on your heat source.
  3. Monitor the temperature displayed on the thermometer. This reading indicates the temperature within the upper section of the Omnia Oven. Adjust your heat source as needed to maintain the desired oven temperature.

6.2. Measuring Food Core Temperature

For precise measurement of the internal temperature of food items (e.g., pastries, roasts):

  1. Carefully insert the pointed probe of the thermometer directly into the thickest part of the food item, avoiding bones or fat.
  2. Ensure the thermometer's display is visible for reading.
  3. Allow a few moments for the reading to stabilize. The displayed temperature is the core temperature of your food. Refer to reliable cooking charts for recommended internal temperatures for various foods.
Omnia Thermometer inserted into a cake baked in an Omnia Oven, demonstrating core temperature measurement.

Figure 5: Measuring Food Core Temperature. The thermometer probe is inserted into a cake to check its internal temperature.

പ്രധാനപ്പെട്ടത്: Always remove the thermometer from food before serving. The probe remains hot after removal.

7. പരിചരണവും പരിപാലനവും

  • വൃത്തിയാക്കൽ: After each use, allow the thermometer to cool completely. Wipe the probe and the body with a damp cloth. Do not immerse the entire thermometer in water. Avoid abrasive cleaners or scouring pads.
  • സംഭരണം: Store the thermometer in a clean, dry place, away from direct sunlight and extreme temperatures. Keep it in a location inaccessible to children.
  • കൈകാര്യം ചെയ്യൽ: Handle the thermometer with care to prevent damage to the probe or the display.

8. പ്രശ്‌നപരിഹാരം

If you encounter issues with your Omnia Thermometer, consider the following:

  • കൃത്യമല്ലാത്ത വായനകൾ: Ensure the probe is fully inserted into the food or properly positioned in the oven. Verify that the thermometer is not damaged. Analog thermometers may have slight variations; for critical applications, cross-reference with another calibrated thermometer if possible.
  • അറ്റാച്ചുചെയ്യാനുള്ള ബുദ്ധിമുട്ട്: Ensure the locking mechanism is correctly aligned with the lid hole and tightened securely. Do not force the thermometer into place.
  • No Movement of Needle: If the needle does not move when exposed to temperature changes, the thermometer may be damaged. Discontinue use and consider replacement.

9 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
മോഡൽ നമ്പർ1130
ബ്രാൻഡ്ഒമ്നിയ
ഉൽപ്പന്ന അളവുകൾ2.36 x 2.76 x 1.97 ഇഞ്ച്
ഇനത്തിൻ്റെ ഭാരം1.41 ഔൺസ്
ബാഹ്യ മെറ്റീരിയൽപ്ലാസ്റ്റിക് (ഭവനം)
ഡിസ്പ്ലേ തരംഅനലോഗ്
പ്രത്യേക ഫീച്ചർഉയർന്ന കൃത്യത
നിറംRed (housing)
FDA കംപ്ലയിന്റ്അതെ

10. വാറൻ്റിയും പിന്തുണയും

For information regarding warranty, returns, or technical support, please refer to the official Omnia webസൈറ്റിൽ ബന്ധപ്പെടുക അല്ലെങ്കിൽ നിങ്ങളുടെ റീട്ടെയിലറെ ബന്ധപ്പെടുക. വാങ്ങിയതിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.

നിർമ്മാതാവ്: Koala Marketing Company AB

അനുബന്ധ രേഖകൾ - 1130

പ്രീview ഓമ്നിയ VOLT SG ക്വിക്ക്-സ്റ്റാർട്ട് ഇൻസ്റ്റലേഷൻ ഗൈഡ്
ഓമ്നിയ VOLT സ്റ്റീരിയോ ജനറേറ്റർ (SG പതിപ്പ്) ബ്രോഡ്‌കാസ്റ്റ് ഓഡിയോ പ്രോസസർ ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനും കോൺഫിഗർ ചെയ്യുന്നതിനുമുള്ള ഒരു ദ്രുത-ആരംഭ ഗൈഡ്, റാക്ക് മൗണ്ടിംഗ്, ഓഡിയോ കണക്ഷനുകൾ, പ്രാരംഭ സജ്ജീകരണം എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview Omnia Smart Lock Model 3111 Installation Instructions Guide
Detailed installation guide for the Omnia Smart Lock Model 3111, covering parts identification, latch and strike installation, exterior and interior assembly, and final testing procedures.
പ്രീview OMNIA OM7-B സ്മാർട്ട് ഡോർ ലോക്ക് ഉപയോക്തൃ മാനുവലും ഇൻസ്റ്റലേഷൻ ഗൈഡും
OMNIA OM7-B സ്മാർട്ട് ഡോർ ലോക്കിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവലും ഇൻസ്റ്റാളേഷൻ ഗൈഡും. മെച്ചപ്പെട്ട ഗാർഹിക സുരക്ഷയ്ക്കായി സാങ്കേതിക സവിശേഷതകൾ, സജ്ജീകരണം, ആപ്പ് ജോടിയാക്കൽ, വിപുലമായ സവിശേഷതകൾ എന്നിവയെക്കുറിച്ച് അറിയുക.
പ്രീview Omnia VOLT (AM Version) Quick-Start Installation Guide
A quick-start guide for installing and configuring the Omnia VOLT (AM Version) broadcast audio processor, covering rack mounting, audio connections, and front-panel setup.
പ്രീview OMNIA Smart Water Timer + Bluetooth Gateway OHCTG-611 User Manual
Comprehensive user manual for the OMNIA OHCTG-611 Smart Water Timer and Bluetooth Gateway. Learn about installation, setup, app connection, operation, specifications, and troubleshooting for smart garden watering.
പ്രീview OMNIA Smart Motion Sensor User Manual
User manual for the OMNIA Smart Motion Sensor, detailing its overview, product parameters, installation instructions, and usage within the Smart Life APP.