1. ആമുഖവും അവസാനവുംview
This manual provides detailed instructions for the installation, operation, and maintenance of the Trine 1000 Series Electric Door Strike, specifically model 1001-2B. This light commercial electric strike is designed for reliable access control in various door applications.

Image 1: The Trine 1001-2B Electric Door Strike. This image displays the brass-colored faceplate and the internal strike mechanism, designed for mortise installation.
The Trine 1001-2B features a 1000 lb. holding force, fail-secure operation, and non-handed design for versatile use. It is engineered to release under slight door pre-load and includes screw terminals for simplified electrical connections. This strike is suitable for new installations or replacements in both wood and metal door jambs, accommodating locksets with up to a 5/8-inch throw, assuming a 1/8-inch door gap.
2. ഉൽപ്പന്ന സവിശേഷതകൾ
- Brass Powder Coating: Durable finish for enhanced longevity.
- 5-7/8" Offset Cavity: Designed for specific installation requirements.
- ബഹുമുഖ ഇൻസ്റ്റാളേഷൻ: Suitable for new or replacement installations in wood and metal jambs.
- Lockset Compatibility: Works with locksets having up to 5/8" throw (with 1/8" door gap).
- Steel Face Plate: Dimensions 5-7/8" x 1-1/4".
- Narrow Style Face Plate: For sleek integration.
- Mortise Backset: 1-1/2".
- അറയുടെ അളവുകൾ: Depth 9/16", Width 9/16", Height 1-11/16".
- പ്രവർത്തന താപനില: Functions reliably between -20°C and 40°C.
- Intermittent Operating Frequency: Designed for intermittent use.
- Fail-Secure Operation: The door remains locked when power is removed.
- Non-Handed Operation: Can be installed on left or right-handed doors.
- സ്ക്രൂ ടെർമിനലുകൾ: For quick and secure electrical connections.
3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
The Trine 1001-2B electric strike is designed for mortise installation in both wood and metal door jambs. Proper installation is crucial for optimal performance and security. It is recommended that installation be performed by a qualified technician.
3.1 പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധനകൾ
- Verify the door and frame are structurally sound and free from damage.
- Ensure the existing lockset has a throw of up to 5/8 inch and that the door gap is approximately 1/8 inch for proper strike engagement.
- Confirm power supply meets the 6-14V AC/DC requirement.
3.2 Mortise Preparation
Carefully prepare the mortise pocket in the door jamb according to the following dimensions:
- Mortise Backset: 1-1/2 ഇഞ്ച്
- അറയുടെ ആഴം: 9/16 ഇഞ്ച്
- Cavity Width: 9/16 ഇഞ്ച്
- Cavity Height: 1-11/16 ഇഞ്ച്
The steel face plate measures 5-7/8 inches x 1-1/4 inches. Ensure the mortise is cut precisely to allow the face plate to sit flush with the jamb surface.
3.3 ഇലക്ട്രിക്കൽ കണക്ഷൻ
- പവർ വിച്ഛേദിക്കുക: Ensure all power to the door system is disconnected before making any electrical connections.
- വയർ കണക്ഷൻ: Connect the power wires to the screw terminals on the electric strike. The strike is non-polarized, so wire orientation does not matter for basic operation.
- പവർ ആവശ്യകതകൾ: The strike operates on 6-14V AC or DC. Refer to your access control system's wiring diagram for specific connections.
- സുരക്ഷിത വയറിംഗ്: ഷോർട്ട് സർക്യൂട്ടുകൾ തടയാൻ എല്ലാ കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും ഇൻസുലേറ്റ് ചെയ്തിട്ടുണ്ടെന്നും ഉറപ്പാക്കുക.
3.4 Mounting the Strike
- Insert the electric strike into the prepared mortise pocket.
- Align the screw holes on the face plate with the pre-drilled holes in the door jamb.
- Secure the strike using the provided screws. Do not overtighten.
- Test the door's operation to ensure the latch bolt engages smoothly with the strike cavity and that there is no binding.
4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The Trine 1001-2B electric strike operates as a fail-secure device, meaning it remains locked when power is not applied. This ensures security during power outages.
- Fail-Secure Operation: When electrical power is removed or interrupted, the strike remains in a locked state, preventing unauthorized entry.
- അൺലോക്ക് ചെയ്യുന്നു: To unlock the door, apply 6-14V AC/DC power to the strike. This retracts the strike's keeper, allowing the door's latch bolt to pass freely and the door to open.
- Relocking: Once power is removed, the strike's keeper returns to its locked position. When the door is closed, the latch bolt will engage with the strike, securing the door.
- Door Pre-load Release: The strike is designed to release effectively even under slight door pre-load, ensuring reliable operation.
- പ്രവർത്തന പരിസ്ഥിതി: The unit is designed to function within a temperature range of -20°C to 40°C.
5. പരിപാലനം
Regular maintenance helps ensure the longevity and reliable operation of your Trine 1001-2B electric strike.
- വൃത്തിയാക്കൽ: Periodically clean the faceplate and keeper mechanism to remove dust and debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
- പരിശോധന: Annually inspect the strike for any signs of wear, damage, or loose screws. Check electrical connections for corrosion or fraying.
- ലൂബ്രിക്കേഷൻ: The internal mechanism is generally maintenance-free. If any stiffness is observed, a small amount of dry lubricant (e.g., graphite powder) can be applied to the moving parts, avoiding contact with electrical components.
- വാതിൽ വിന്യാസം: Ensure the door and frame remain properly aligned. Misalignment can cause excessive wear on the strike and latch bolt.
6. പ്രശ്നപരിഹാരം
If you encounter issues with your Trine 1001-2B electric strike, refer to the following common troubleshooting steps:
- Strike Does Not Unlock:
- Check power supply: Ensure 6-14V AC/DC is being delivered to the strike when activated.
- Inspect wiring: Verify all electrical connections are secure and free from damage or corrosion.
- Check access control system: Ensure the access control system (keypad, card reader, etc.) is functioning correctly and sending the unlock signal.
- Door binding: Check if the door or latch bolt is binding against the strike. Adjust door alignment if necessary.
- Strike Does Not Lock:
- Power constantly applied: In a fail-secure setup, if power is continuously applied, the strike will remain unlocked. Ensure power is removed when the door should be locked.
- Mechanical obstruction: Check for any debris or foreign objects obstructing the keeper mechanism.
- Damaged keeper: Inspect the keeper for physical damage that might prevent it from returning to the locked position.
- പ്രവർത്തന സമയത്ത് അമിതമായ ശബ്ദം:
- Loose mounting screws: Tighten all mounting screws on the faceplate.
- Misalignment: Minor adjustments to door or strike alignment may be needed.
If issues persist after performing these steps, contact a qualified technician or Trine customer support for further assistance.
7 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ നമ്പർ | 1001-2B (Variant: 1001-2B-6-12) |
| ബ്രാൻഡ് | ട്രൈൻ |
| ലോക്ക് തരം | മോർട്ടൈസ് ലോക്ക് |
| പ്രത്യേക ഫീച്ചർ | Fail-Secure Operation |
| മെറ്റീരിയൽ | Alloy Steel, Brass, Metal |
| ശുപാർശ ചെയ്യുന്ന ഉപയോഗങ്ങൾ | Door lock installations and replacements |
| പവർ ആവശ്യകതകൾ | 6-14V എസി/ഡിസി |
| ഹോൾഡിംഗ് ഫോഴ്സ് | 1000 പൗണ്ട് |
| Face Plate Dimensions | 5-7/8" x 1-1/4" |
| Mortise Backset | 1-1/2" |
| അറയുടെ ആഴം | 9/16" |
| അറയുടെ വീതി | 9/16" |
| അറയുടെ ഉയരം | 1-11/16" |
| പ്രവർത്തന താപനില | -20°C മുതൽ 40°C വരെ |
| ഇനത്തിൻ്റെ ഭാരം | 0.31 കിലോഗ്രാം (10.8 ഔൺസ്) |
| യു.പി.സി | 822786001572 |
8. വാറൻ്റിയും പിന്തുണയും
For information regarding the product warranty, please refer to the documentation provided at the time of purchase or contact Trine customer support directly. Warranty terms and conditions may vary.