1. ആമുഖം
The Veanic Mini Digital Hygrometer Thermometer Gauge (Model GCM0802) is a compact device designed to accurately monitor both temperature and humidity. Featuring an external probe and an LCD display, this unit provides essential environmental data for various applications, including reptile terrariums, plant greenhouses, incubators, and humidors. This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your device.
2. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Veanic Mini Digital Hygrometer Thermometer Gauge consists of a main display unit and a remote sensor probe. The display shows real-time temperature in Fahrenheit and relative humidity percentage. The external probe allows for precise measurements in specific locations while the main unit remains easily viewകഴിവുള്ള.

Image 1: Two Veanic Mini Digital Hygrometer Thermometer Gauges, showing the main display unit and the wired sensor probe.

Image 2: Diagram illustrating the 2-in-1 functionality, displaying temperature and humidity ranges.
3 സ്പെസിഫിക്കേഷനുകൾ
| മോഡൽ | GCM0802 |
| ഡിസ്പ്ലേ തരം | എൽസിഡി |
| അളവുകൾ (പ്രധാന യൂണിറ്റ്) | 1.89 x 1.13 x 0.6 ഇഞ്ച് (48 x 28.6 x 15.2 മിമി) |
| കേബിൾ നീളം | 59 ഇഞ്ച് (1.5 മീറ്റർ) |
| താപനില അളക്കൽ ശ്രേണി | -58℉ മുതൽ 158℉ വരെ (-50℃ മുതൽ 70℃ വരെ) |
| താപനില അളക്കൽ കൃത്യത | ±2℉ (±1℃) |
| ഈർപ്പം അളക്കുന്നതിനുള്ള ശ്രേണി | 10% മുതൽ 99% വരെ RH |
| ഈർപ്പം അളക്കൽ കൃത്യത | ±5% RH |
| ഈർപ്പം എസ്ampലിംഗ കാലയളവ് | 10 സെക്കൻഡ് |
| പവർ ഉറവിടം | 2 x LR44 button cells (included) |
| മെറ്റീരിയൽ | പ്ലാസ്റ്റിക് |

Image 3: Detailed dimensions of the main unit and cable length.
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
- ബാറ്ററി ഇൻസ്റ്റാളേഷൻ: The device comes with 2 LR44 button cell batteries pre-installed. If the display is blank or dim, replace the batteries. To do this, locate the battery compartment on the back of the main unit, open it, and insert new LR44 batteries, ensuring correct polarity.
- Placement of Main Unit: Position the main display unit in a location where it can be easily read.
- പ്രോബ് പ്ലേസ്മെൻ്റ്: Extend the wired sensor probe into the environment you wish to monitor (e.g., terrarium, incubator, humidor). Ensure the probe tip is positioned to accurately reflect the conditions of that specific area.
- പ്രധാന കുറിപ്പ്: The sensor probe is ജല പ്രതിരോധശേഷിയുള്ളതല്ല. Do not immerse the probe in water or use it in aquatic environments such as fish tanks. Exposure to water will damage the sensor.

ചിത്രം 4: ഉദാample of the remote sensor probe installed in a reptile terrarium, highlighting its independent placement.
5. ഓപ്പറേഷൻ
Once the batteries are installed and the probe is placed, the device will automatically begin displaying the current temperature and humidity readings on its LCD screen. The temperature is displayed in Fahrenheit (℉), and the humidity is shown as a percentage (%). The device updates its readings approximately every 10 seconds.

Image 5: Various applications for the hygrometer, including humidors, incubators, reptile terrariums, and plant terrariums.
6. പരിപാലനം
- വൃത്തിയാക്കൽ: To clean the device, gently wipe the main unit and probe with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ: When the display becomes dim or stops functioning, replace the LR44 button cell batteries as described in the Setup section.
- സംഭരണം: ഉപകരണം ദീർഘനേരം സൂക്ഷിക്കുകയാണെങ്കിൽ, ചോർച്ച തടയാൻ ബാറ്ററികൾ നീക്കം ചെയ്ത് തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് സൂക്ഷിക്കുക.
7. പ്രശ്നപരിഹാരം
- ശൂന്യമായ ഡിസ്പ്ലേ: If the display is blank, check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- കൃത്യമല്ലാത്ത വായനകൾ: Ensure the probe is positioned correctly and not obstructed. Allow sufficient time (at least 15-30 minutes) for the readings to stabilize after initial setup or significant environmental changes.
- No Reading from Probe: Verify that the probe cable is securely connected to the main unit.
8 സുരക്ഷാ വിവരങ്ങൾ
- ബാറ്ററികൾ കുട്ടികൾക്ക് ലഭ്യമാകാതെ സൂക്ഷിക്കുക. വിഴുങ്ങിയാൽ ഉടൻ വൈദ്യസഹായം തേടുക.
- Do not expose the device or probe to extreme temperatures or direct sunlight for prolonged periods.
- As noted, the probe is not waterproof. Avoid contact with liquids to prevent damage and ensure accurate readings.
- ഉപയോഗിച്ച ബാറ്ററികൾ പ്രാദേശിക ചട്ടങ്ങൾക്കനുസൃതമായി നീക്കം ചെയ്യുക.
9. വാറൻ്റിയും പിന്തുണയും
For warranty information or technical support, please contact Veanic customer service through the retailer where the product was purchased. Please have your model number (GCM0802) and purchase details available when contacting support.