Locinox VERTICLOSE-2-9005

Locinox Verticlose 2 Hydraulic Gate Closer Instruction Manual

1. ആമുഖം

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Locinox Verticlose 2 Hydraulic Gate Closer. Designed for both 90° and 180° hinge applications, this gate closer features integrated pre-tension, adjustable closing speed, and a final snap mechanism. The Quick-Fix mounting system facilitates efficient installation, and its anodized aluminum construction ensures durability.

2. ഉൽപ്പന്ന സവിശേഷതകൾ

  • Micro adjustment of speed and final snap for precise gate closing.
  • Includes railset for versatile installation in 90° and 180° hinge situations.
  • Weatherproof, scratch-resistant, and corrosion-free anodized aluminum housing ensures longevity.
  • Robust and stylish design with high-quality internal components.
  • Integrated pre-tension for smooth and efficient installation.
  • Consistent closing speed maintained by patented hydraulic dampസാങ്കേതികവിദ്യ.
  • Securely fixed using the patented Quick-Fix system.
  • ADA compliant (< 5 lbs; max 25 Nm) for gate widths of 4ft or more.

3 സുരക്ഷാ വിവരങ്ങൾ

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in injury or product damage.

  • ഇൻസ്റ്റാളേഷൻ സമയത്ത് സുരക്ഷാ ഗ്ലാസുകളും കയ്യുറകളും ഉൾപ്പെടെ ഉചിതമായ വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ (പിപിഇ) എല്ലായ്പ്പോഴും ധരിക്കുക.
  • Ensure the gate is securely supported during installation to prevent accidental movement.
  • Do not attempt to disassemble the hydraulic unit. It contains pressurized components.
  • Keep hands and clothing clear of moving parts during operation and adjustment.
  • This product is designed for gate closing applications only. Do not use for other purposes.

4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

The Verticlose 2 is designed for efficient installation using the Quick-Fix mounting system. The included railset supports both 90° and 180° hinge configurations.

4.1 പാക്കേജ് ഉള്ളടക്കം

  • Verticlose 2 Hydraulic Gate Closer unit
  • Railset for 90° and 180° situations
  • Quick-Fix mounting hardware
  • ഇൻസ്ട്രക്ഷൻ മാനുവൽ

4.2 ഇൻസ്റ്റലേഷൻ ഘട്ടങ്ങൾ

  1. Prepare the Gate and Post: Ensure the gate and post are structurally sound and free from obstructions.
  2. Mount the Quick-Fix System: Attach the Quick-Fix mounting plates to the gate and post according to the desired hinge situation (90° or 180°). Refer to the diagrams for precise positioning.
  3. Install the Closer Unit: Securely attach the Verticlose 2 hydraulic unit to the Quick-Fix mounting plates. The integrated pre-tension feature will assist in this step.
  4. Connect the Railset: Attach the appropriate railset components between the closer unit and the gate/post, ensuring proper alignment.
  5. പ്രാരംഭ ക്രമീകരണം: Perform an initial check of the gate's movement and make preliminary adjustments to the closing speed and final snap as described in Section 5.
Locinox Verticlose 2 Hydraulic Gate Closer with mounting arms

ചിത്രം 1: The Locinox Verticlose 2 Hydraulic Gate Closer shown with its main cylindrical body and the two railset arms for mounting.

5. പ്രവർത്തനവും ക്രമീകരണവും

The Verticlose 2 allows for precise adjustment of the closing speed and final snap to suit specific gate requirements.

5.1 Adjusting Closing Speed

Locate the speed adjustment screw on the closer unit. Turning the screw clockwise will decrease the closing speed, making the gate close slower. Turning it counter-clockwise will increase the closing speed, making the gate close faster. Make small adjustments and test the gate's movement after each adjustment.

5.2 Adjusting Final Snap

The final snap adjustment controls the force with which the gate latches shut in the last few degrees of closing. Locate the final snap adjustment screw. Turning it clockwise will increase the snap force, while turning it counter-clockwise will decrease it. Adjust as needed to ensure the gate securely latches without excessive force.

6. പരിപാലനം

Regular maintenance ensures optimal performance and extends the lifespan of your Verticlose 2 gate closer.

  • വൃത്തിയാക്കൽ: Periodically clean the exterior of the closer unit and railset with a soft, damp അഴുക്കും അവശിഷ്ടങ്ങളും നീക്കം ചെയ്യാൻ തുണി ഉപയോഗിക്കുക. ഉരച്ചിലുകൾ ഉള്ള ക്ലീനറുകൾ ഒഴിവാക്കുക.
  • പരിശോധന: Annually inspect all mounting hardware for tightness. Check the railset for any signs of wear or damage.
  • ലൂബ്രിക്കേഷൻ: The hydraulic unit is sealed and does not require internal lubrication. Ensure any moving pivot points on the railset are free of obstruction.
  • പ്രകടന പരിശോധന: Periodically check the closing speed and final snap. Readjust if necessary due to environmental changes or wear.

7. പ്രശ്‌നപരിഹാരം

This section addresses common issues you might encounter with your Verticlose 2 gate closer.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
Gate closes too fast/slowSpeed adjustment incorrectAdjust the closing speed screw (refer to Section 5.1).
Gate does not latch securelyFinal snap adjustment incorrectAdjust the final snap screw (refer to Section 5.2).
Gate binds or sticksObstruction in gate path or hinge issuesCheck for physical obstructions. Inspect gate hinges for proper function and lubrication.
Closer unit leaking fluidInternal seal failureContact Locinox customer support for assistance. Do not attempt to repair.

8 സാങ്കേതിക സവിശേഷതകൾ

മോഡൽ നമ്പർVERTICLOSE-2-9005
ബ്രാൻഡ്ലോക്കിനോക്സ്
മെറ്റീരിയൽഅലുമിനിയം
നിറംകറുപ്പ്
എക്സ്റ്റീരിയർ ഫിനിഷ്കറുപ്പ്
ഇനത്തിൻ്റെ ഭാരം11.53 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ2.5 x 3 x 15.5 ഇഞ്ച്
ഇൻസ്റ്റലേഷൻ തരംസ്ക്രൂ-ഇൻ
ശുപാർശ ചെയ്യുന്ന ഉപയോഗങ്ങൾCommercial buildings, high-traffic areas
സ്പെസിഫിക്കേഷൻ മെറ്റ്എ.ഡി.എ

9. വാറൻ്റിയും പിന്തുണയും

For warranty information, technical support, or replacement parts, please contact Locinox customer service directly. Refer to the official Locinox webബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങൾക്ക് സൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ വാങ്ങൽ ഡോക്യുമെന്റേഷൻ.

അനുബന്ധ രേഖകൾ - VERTICLOSE-2-9005

പ്രീview വെർട്ടിക്ലോസ്-2 വാൾ ഡോർ ക്ലോസർ ഇൻസ്റ്റലേഷൻ ഗൈഡ്
ലോക്കിനോക്‌സിന്റെ വെർട്ടിക്ലോസ്-2 വാൾ ഡോർ ക്ലോസറിനായുള്ള സമഗ്രമായ ഇൻസ്റ്റാളേഷൻ ഗൈഡ്, ശരിയായ മൗണ്ടിംഗിനും പ്രവർത്തനത്തിനുമുള്ള എല്ലാ ഘട്ടങ്ങളും ഘടകങ്ങളും സവിശേഷതകളും വിശദമാക്കുന്നു.
പ്രീview ലോക്കിനോക്സ് പാന്തർ ഹൈഡ്രോളിക് ഗേറ്റ് ക്ലോസർ ഇൻസ്റ്റലേഷൻ ഗൈഡും സ്പെസിഫിക്കേഷനുകളും
ലോക്കിനോക്സ് പാന്തർ ഹൈഡ്രോളിക് ഗേറ്റ് ക്ലോസറിനായുള്ള സമഗ്രമായ ഇൻസ്റ്റലേഷൻ ഗൈഡും സാങ്കേതിക സവിശേഷതകളും, അളവുകൾ, മൗണ്ടിംഗ് നിർദ്ദേശങ്ങൾ, ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ എന്നിവയുൾപ്പെടെ.
പ്രീview ലോക്കിനോക്സ് CLB-MAMMOTH ഗേറ്റ് ഹിഞ്ച് ഇൻസ്റ്റലേഷൻ ഗൈഡ്
ലോക്കിനോക്സ് CLB-MAMMOTH ഗേറ്റ് ഹിഞ്ച് സിസ്റ്റത്തിനായുള്ള ഔദ്യോഗിക ഇൻസ്റ്റാളേഷൻ ഗൈഡ്. പോസ്റ്റുകളിലും ഗേറ്റ് ഫ്രെയിമുകളിലും ഘടിപ്പിക്കുന്നതിനുള്ള വിശദമായ നിർദ്ദേശങ്ങൾ, ഡയഗ്രമുകൾ, സ്പെസിഫിക്കേഷനുകൾ എന്നിവ നൽകുന്നു. അലൈൻമെന്റ്, ഡ്രില്ലിംഗ്, അറ്റാച്ച്മെന്റ് നടപടിക്രമങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview Locinox MAMMOTH-180 ഗേറ്റ് ക്ലോസർ ഇൻസ്റ്റാളേഷനും ഉപയോക്തൃ ഗൈഡും
Locinox MAMMOTH-180 ഗേറ്റ് ക്ലോസറും ഡിനോ ഹിഞ്ചും ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനും ഉപയോഗിക്കുന്നതിനുമുള്ള സമഗ്രമായ ഗൈഡ്. സ്പെസിഫിക്കേഷനുകൾ, അളവുകൾ, പ്രോ എന്നിവ ഉൾക്കൊള്ളുന്നു.file തയ്യാറാക്കൽ, മൗണ്ടിംഗ്, ക്രമീകരണങ്ങൾ, അന്തിമമാക്കൽ.
പ്രീview Locinox SUBY Drop Bolt Installation Guide
Official installation manual for the Locinox SUBY drop bolt, detailing dimensions, components, and step-by-step assembly instructions for gate hardware.
പ്രീview LOCINOX MAGNUS Gate Motor: Installation, Safety, and Technical Guide
This guide provides essential information for the installation, safe operation, and technical specifications of the LOCINOX MAGNUS gate motor. It covers safety notices, connection diagrams, and product details for automated swing gates.