1. ആമുഖം
Thank you for choosing the EASYLONGER ES400 AIR CPAP Battery. This portable power supply is designed to provide reliable and uninterrupted power for your CPAP machine and other electronic devices, whether you are campഒരു ശക്തി അനുഭവിക്കുക, സഞ്ചരിക്കുക, അല്ലെങ്കിൽtage. With its 148Wh capacity and multiple output ports, the ES400 AIR ensures you can maintain your therapy and stay connected wherever you are. This manual provides essential information for the safe and efficient use of your device.
2 സുരക്ഷാ വിവരങ്ങൾ
Please read all safety instructions carefully before using the EASYLONGER ES400 AIR. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- ബാറ്ററിയെ തീവ്രമായ താപനിലയിലോ, നേരിട്ടുള്ള സൂര്യപ്രകാശത്തിലോ, ഉയർന്ന ആർദ്രതയിലോ തുറന്നുകാട്ടരുത്.
- Do not disassemble, repair, or modify the device. Refer all servicing to qualified personnel.
- ഉപകരണം വെള്ളത്തിൽ നിന്നും കത്തുന്ന ദ്രാവകങ്ങളിൽ നിന്നും അകറ്റി നിർത്തുക.
- അമിതമായി ചൂടാകുന്നത് തടയാൻ ഉപയോഗിക്കുമ്പോഴും ചാർജ് ചെയ്യുമ്പോഴും ശരിയായ വായുസഞ്ചാരം ഉറപ്പാക്കുക.
- The built-in Battery Management System (BMS) protects against over-charging, over-discharging, over-current, and short-circuits.
- എയർലൈൻ യാത്ര: The ES400 AIR has a 148Wh capacity. While generally considered airline-friendly, prior approval from the airline is required before boarding. Always carry the battery in your carry-on luggage; ചെയ്യരുത് place it in checked baggage.
- CPAP Usage: Using CPAP machines with humidifiers and heated tubes significantly increases power consumption and reduces battery runtime. For extended use, it is recommended to turn off these features.
3. പാക്കേജ് ഉള്ളടക്കം
നിങ്ങളുടെ പാക്കേജിൽ എല്ലാ ഇനങ്ങളും ഉണ്ടെന്ന് ഉറപ്പാക്കുക:
- 1 x 148Wh CPAP Battery (EASYLONGER ES400 AIR)
- 1 x എസി അഡാപ്റ്റർ
- 1 x DC Cable for ResMed S9
- 1 x DC Cable for AirSense 10/AirCurve 10
- 1 x DC Cable for AirMini/AirSense 11
- 1 x DC Cable for Philips DreamStation
- 1 x USB A-C Cable
- 1 x ചുമക്കുന്ന ബാഗ്
- 1 x ഉപയോക്തൃ മാനുവൽ (ഈ പ്രമാണം)
4. ഉൽപ്പന്നം കഴിഞ്ഞുview

ചിത്രം 4.1: ഫ്രണ്ട് view of the EASYLONGER ES400 AIR CPAP Battery, highlighting the DC IN/OUT, USB-C OUT, USB-A OUT ports, and the digital display.
The EASYLONGER ES400 AIR is a compact and robust power bank designed for portability and durability. It features a clear digital display showing output voltagഇ, ബാറ്ററി ശതമാനംtage. The device includes multiple output ports to accommodate various devices:
- DC IN/OUT Port: Used for charging the battery and for connecting CPAP machines via the included DC cables. Supports adjustable voltage output (12V, 16.5V, 20V, 24V).
- USB-C OUT Port: 30W Power Delivery (PD) for fast charging compatible devices like laptops, tablets, and smartphones.
- USB-A OUT Port: 18W Power Delivery (PD) for charging smartphones and other USB-powered devices.
- DC 12V OUT (Car Socket) Port: 160W output for devices requiring a car cigarette lighter connection, such as air pumps or car refrigerators.
5. സജ്ജീകരണം
Before first use, fully charge your EASYLONGER ES400 AIR battery.
5.1 പ്രാരംഭ ചാർജിംഗ്
Connect the included AC adapter to the DC IN/OUT port on the battery and plug it into a wall outlet. The digital display will show the charging progress. A full charge typically takes 4-5 hours.
5.2 Connecting to CPAP Machine

ചിത്രം 5.1: Included CPAP cables for various machine models.

ചിത്രം 5.2: Options for powering your CPAP machine.
The ES400 AIR comes with 4 specific DC cables for direct connection to popular CPAP models. Before connecting, ensure the correct voltage is selected on the battery to match your CPAP machine's requirements (12V, 16.5V, 20V, or 24V). Refer to your CPAP machine's manual for its specific voltage.
- Direct Connection (Recommended): Use one of the included DC cables that matches your CPAP machine. Connect one end to the battery's DC IN/OUT port and the other to your CPAP machine.
- Using a Cigarette Lighter Cable with a Voltage Converter (Sold Separately): For CPAP machines not directly supported by the included cables, you may use a cigarette lighter cable with an appropriate voltage converter connected to the battery's DC 12V OUT (car socket) port.
- Using an Inverter (Sold Separately): For broader compatibility, an AC inverter can be connected to the battery's DC 12V OUT (car socket) port, allowing you to power your CPAP machine using its standard AC adapter. Note that using an inverter can decrease overall runtime due to energy conversion loss.
6. പ്രവർത്തിക്കുന്നു
6.1 പവർ ഓൺ/ഓഫ്
Press and hold the power button for a few seconds to turn the unit on or off. The digital display will illuminate, showing the battery level and output voltage.
6.2 ഔട്ട്പുട്ട് പോർട്ടുകൾ ഉപയോഗിക്കൽ
- DC IN/OUT: After setting the correct voltage, connect your CPAP machine. The display will show the active output voltage.
- USB-C OUT & USB-A OUT: Simply plug your USB devices into the respective ports. These ports are always on when the unit is powered, and the LED display will light up once a device is plugged in.
- DC 12V OUT (Car Socket): Plug in your 12V car-compatible devices. This port is also always on when the unit is powered.
6.3 പാസ്-ത്രൂ ചാർജിംഗ്

ചിത്രം 6.1: Pass-Through Charging in action.
The ES400 AIR supports pass-through charging, allowing you to charge the battery while simultaneously powering your CPAP machine or other devices. This feature ensures uninterrupted power, acting as a backup power supply in case of a power outage. For CPAP machines, this functionality works directly with the included DC cables. If using a voltage converter or inverter, ensure they also support pass-through functionality.
7. ചാർജിംഗ് ഓപ്ഷനുകൾ

ചിത്രം 7.1: Three recharging options for the ES400 AIR.
Your EASYLONGER ES400 AIR offers versatile recharging methods:
- എസി അഡാപ്റ്റർ (ഉൾപ്പെടുത്തിയിരിക്കുന്നു): Connect the 40W AC adapter to a standard wall outlet. Fully charges in approximately 4-5 hours.
- Car Charger (Not Included): Use a compatible car charger plugged into your vehicle's 12V cigarette lighter socket. Fully charges in approximately 2-3 hours.
- Solar Panel (Not Included): The battery features built-in MPPT technology, supporting inputs up to 72W. An 80W solar panel can fully charge the battery in approximately 3-4 hours, depending on sunlight conditions.
8. Compatibility & Runtime
8.1 CPAP Machine Compatibility

ചിത്രം 8.1: Direct compatibility with included cables.

ചിത്രം 8.2: Broad compatibility with an inverter (sold separately).
The ES400 AIR is designed to be compatible with most CPAP machines on the market. The included DC cables provide direct compatibility with:
- ResMed AirSense 11, AirSense 10, AirCurve 10, AirMini, ResMed S9
- Philips DreamStation, DreamStation 2
For other CPAP models, compatibility can be achieved using a separate voltage converter or an AC inverter connected to the battery's 12V car socket output.
8.2 Factors Affecting Runtime

ചിത്രം 8.3: Impact of humidifier and heated tube on runtime.

ചിത്രം 8.4: Comprehensive list of factors affecting battery duration.
The actual runtime of the ES400 AIR when powering a CPAP machine can vary significantly based on several factors:
- Humidifier and Heated Tube Settings: These features consume significant power. Turning them off or setting them to zero will greatly extend battery life.
- CPAP Pressure Settings: Higher pressure settings generally require more power.
- Ramp Up Function: Using this feature can affect power consumption.
- Altitude Compensation: If enabled, this feature may impact power usage.
- Mask Leaks: Significant mask leaks can cause the CPAP machine to work harder, consuming more power.
- മെഷീൻ തരം: Different CPAP models have varying power efficiencies.
- Use of Inverter: Using an AC inverter introduces energy loss, reducing overall runtime compared to direct DC connection.
- ആംബിയൻ്റ് താപനില: ഉയർന്ന താപനില ബാറ്ററി പ്രകടനത്തെ ബാധിച്ചേക്കാം.
Estimated Runtimes (Humidification and Heating OFF, Ambient Temperature: 25°C / 77°F):
| CPAP മോഡൽ | Pressure (cm H₂O) | Estimated Run Time |
|---|---|---|
| റെസ്മെഡ് എയർമിനി | 8 | 18 മണിക്കൂർ |
| റെസ്മെഡ് എയർമിനി | 12 | 16 മണിക്കൂർ |
| റെസ്മെഡ് എയർമിനി | 16 | 12 മണിക്കൂർ |
| എയർസെൻസ് 11 | 6-8 | 14 മണിക്കൂർ |
| എയർസെൻസ് 11 | 10-12 | 12 മണിക്കൂർ |
| എയർസെൻസ് 11 | 14-16 | 9 മണിക്കൂർ |
| എയർസെൻസ് 10 | 6-8 | 14 മണിക്കൂർ |
| എയർസെൻസ് 10 | 10-12 | 12 മണിക്കൂർ |
| എയർസെൻസ് 10 | 14-16 | 9 മണിക്കൂർ |
| ഡ്രീംസ്റ്റേഷൻ 2 | 8 | 15 മണിക്കൂർ |
| ഡ്രീംസ്റ്റേഷൻ 2 | 12 | 13 മണിക്കൂർ |
| ഡ്രീംസ്റ്റേഷൻ 2 | 16 | 9 മണിക്കൂർ |
9. പരിപാലനം
Proper maintenance ensures the longevity and optimal performance of your EASYLONGER ES400 AIR battery.
- വൃത്തിയാക്കൽ: ഉപകരണത്തിന്റെ പുറംഭാഗം വൃത്തിയാക്കാൻ മൃദുവായതും ഉണങ്ങിയതുമായ തുണി ഉപയോഗിക്കുക. അബ്രസീവ് ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
- സംഭരണം: Store the battery in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, charge the battery to approximately 50-70% every 3-6 months to maintain battery health.
- ബാറ്ററി കെയർ: Avoid fully discharging the battery frequently, as this can reduce its lifespan. Recharge the battery as soon as possible after use.
10. പ്രശ്നപരിഹാരം
If you encounter issues with your EASYLONGER ES400 AIR, refer to the following common troubleshooting steps:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ബാറ്ററി ചാർജ് ചെയ്യുന്നില്ല | AC adapter not connected properly; Faulty adapter or cable; Battery too hot/cold. | Ensure all connections are secure. Try a different outlet. Allow battery to reach room temperature. Contact support if issue persists. |
| Device not powering CPAP | തെറ്റായ വോളിയംtage setting; Incorrect DC cable used; CPAP machine power requirements too high (e.g., humidifier ON); Battery discharged. | വോളിയം പരിശോധിക്കുകtage setting matches your CPAP. Ensure the correct DC cable is used. Turn off humidifier/heated tube. Recharge the battery. |
| ചെറിയ റൺടൈം | Humidifier/heated tube ON; High CPAP pressure; Mask leaks; Using an inverter. | Turn off humidifier/heated tube. Check for mask leaks. Consider direct DC connection instead of inverter. |
| USB പോർട്ടുകൾ പ്രവർത്തിക്കുന്നില്ല | Device not powered on; Cable issue; Device not compatible. | Ensure the battery is powered on. Try a different USB cable. Check device compatibility with USB-C PD or USB-A. |
For more detailed troubleshooting or issues not listed here, please refer to the full User Manual PDF available online or contact EASYLONGER customer support.
11 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ നമ്പർ | GP48 AIR (ES400 AIR) |
| ബാറ്ററി തരം | ലിഥിയം അയോൺ |
| ശേഷി | 148Wh / 40000mAh |
| ഉൽപ്പന്ന അളവുകൾ | 7.28 x 4.76 x 1.57 ഇഞ്ച് |
| ഇനത്തിൻ്റെ ഭാരം | 2.05 പൗണ്ട് |
| DC IN/OUT Voltage | 12V, 16.5V, 20V, 24V (3.5A) |
| USB-C ഔട്ട്പുട്ട് | 30W Power Delivery (PD) Max |
| യുഎസ്ബി-എ put ട്ട്പുട്ട് | 18W Power Delivery (PD) Max |
| DC 12V OUT (Car Socket) | 160W പരമാവധി |
| Recharge Time (AC Adapter) | 4-5 മണിക്കൂർ |
| Recharge Time (Car Charger) | 2-3 മണിക്കൂർ |
| Recharge Time (Solar Panel) | 3-4 hours (with 80W panel) |
| പ്രത്യേക സവിശേഷതകൾ | Travel, Over Voltage Protection, Fast Charging, Built-in BMS |
| നിർമ്മാതാവ് | Dongguan Yihang Electronic Co., Ltd |
| ആദ്യ തീയതി ലഭ്യമാണ് | മെയ് 9, 2023 |
12. വാറൻ്റിയും പിന്തുണയും
EASYLONGER products are manufactured with high-quality materials and undergo rigorous testing. For warranty information and customer support, please refer to the warranty card included in your package or visit the official EASYLONGER webസൈറ്റ്. നിങ്ങൾക്ക് എന്തെങ്കിലും ചോദ്യങ്ങളുണ്ടെങ്കിലോ സഹായം ആവശ്യമുണ്ടെങ്കിലോ, ഞങ്ങളുടെ ഉപഭോക്തൃ സേവന ടീമുമായി ബന്ധപ്പെടാൻ മടിക്കരുത്.
ഓൺലൈൻ ഉറവിടങ്ങൾ:
- ഉപയോക്തൃ ഗൈഡ് (PDF): ഉപയോക്തൃ ഗൈഡ് ഡൗൺലോഡ് ചെയ്യുക
- ഉപയോക്തൃ മാനുവൽ (PDF): ഉപയോക്തൃ മാനുവൽ ഡൗൺലോഡ് ചെയ്യുക
- EASYLONGER Store: Visit EASYLONGER Store on Amazon





