റെസ്നോർ യുഡിഎക്സ്സി-125

റെസ്നോർ UDXC-125 നാച്ചുറൽ ഗ്യാസ് യൂണിറ്റ് ഹീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ

മോഡൽ: UDXC-125 | ബ്രാൻഡ്: റെസ്നോർ

1. ആമുഖം

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Reznor UDXC-125 Natural Gas Unit Heater. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.

The Reznor UDXC-125 is a 120,000 BTU natural gas-fired, forced-air unit heater designed for indoor use in various commercial, industrial, and residential spaces such as garages, workshops, and warehouses. It features an 83% thermal efficiency rating and is built with durable components for reliable performance.

Reznor UDXC-125 Natural Gas Unit Heater, front view

ചിത്രം 1: മുൻഭാഗം view of the Reznor UDXC-125 Natural Gas Unit Heater. This image displays the compact design of the heater with its front grille and the Reznor branding on the side.

2 സുരക്ഷാ വിവരങ്ങൾ

മുന്നറിയിപ്പ്: അനുചിതമായ ഇൻസ്റ്റാളേഷൻ, ക്രമീകരണം, മാറ്റം, സേവനം, അല്ലെങ്കിൽ അറ്റകുറ്റപ്പണികൾ എന്നിവ വസ്തുവകകളുടെ കേടുപാടുകൾ, പരിക്കുകൾ അല്ലെങ്കിൽ മരണം എന്നിവയ്ക്ക് കാരണമാകും. ഈ ഉപകരണം ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനോ അല്ലെങ്കിൽ സർവീസ് ചെയ്യുന്നതിനോ മുമ്പ് ഇൻസ്റ്റാളേഷൻ, ഓപ്പറേറ്റിംഗ്, മെയിന്റനൻസ് നിർദ്ദേശങ്ങൾ നന്നായി വായിക്കുക.

ഈ ഉൽപ്പന്നത്തിൽ കാൻസർ, ജനന വൈകല്യങ്ങൾ അല്ലെങ്കിൽ മറ്റ് പ്രത്യുൽപാദന തകരാറുകൾ എന്നിവയ്ക്ക് കാരണമാകുന്ന രാസവസ്തുക്കൾ കാലിഫോർണിയ സംസ്ഥാനത്തിന് അറിയാം. കൂടുതൽ വിവരങ്ങൾക്ക്, സന്ദർശിക്കുക www.P65Warnings.ca.gov.

  • Always ensure proper ventilation when operating the heater.
  • ഈ അല്ലെങ്കിൽ മറ്റേതെങ്കിലും ഉപകരണത്തിൻ്റെ പരിസരത്ത് ഗ്യാസോലിൻ അല്ലെങ്കിൽ മറ്റ് കത്തുന്ന നീരാവി, ദ്രാവകങ്ങൾ എന്നിവ സൂക്ഷിക്കുകയോ ഉപയോഗിക്കുകയോ ചെയ്യരുത്.
  • Keep the area around the heater clear of combustible materials.
  • ഇൻസ്റ്റാളേഷനും സേവനവും ഒരു യോഗ്യതയുള്ള ഇൻസ്റ്റാളർ, സേവന ഏജൻസി അല്ലെങ്കിൽ ഗ്യാസ് വിതരണക്കാരൻ നിർവഹിക്കണം.
  • Ensure all gas and electrical connections comply with local codes and regulations.

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

The Reznor UDXC-125 heater is designed for indoor use and can be mounted from the ceiling or on a wall. Mounting hardware is sold separately. Ensure the chosen location provides adequate clearance from combustible materials and allows for proper venting.

3.1 മൗണ്ടിംഗ് ഓപ്ഷനുകൾ

The unit features threaded-nut retainers at four suspension points, facilitating secure ceiling or wall mounting. Consult local building codes for specific mounting requirements.

Reznor UDXC-125 Unit Heater mounted from ceiling

Figure 2: Reznor UDXC-125 Unit Heater suspended from a ceiling. This image illustrates the heater's capability for ceiling installation, highlighting its compact form factor in an industrial setting.

3.2 വെന്റിങ് ആവശ്യകതകൾ

This unit is compatible with Category 3 single-wall vent pipe. Venting can be configured vertically through a roof or horizontally through a sidewall. Proper venting is crucial for safety and efficient operation, ensuring exhaust gases are safely expelled.

3.3 ഗ്യാസ്, ഇലക്ട്രിക്കൽ കണക്ഷനുകൾ

  • An external gas connection point is provided for ease of maintenance and installation.
  • The unit requires a 24V electrical connection, accessible via an external terminal strip.
  • A built-in enhanced disconnect switch is included for safety during service.
  • All connections must be made by a licensed professional in accordance with all applicable local and national codes.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The Reznor UDXC-125 features an integrated circuit board with a 7-segment display and status-indicating LED for operational feedback.

4.1 ഹീറ്റർ ആരംഭിക്കുന്നു

  1. ഗ്യാസ് വിതരണ വാൽവ് തുറന്നിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക.
  2. Verify electrical power is supplied to the unit and the disconnect switch is in the "ON" position.
  3. Set the thermostat to the desired temperature. The heater will initiate its ignition sequence.
  4. The status-indicating LED and 7-segment display will provide feedback during startup and operation.

4.2 Heating Flexibility

The single-burner design offers two BTU outputs, allowing for efficient heating in varying conditions. A higher output is available for colder days, and a lower output for milder temperatures, optimizing energy use.

Reznor UDXC-125 Unit Heater in a workshop setting

Figure 3: Reznor UDXC-125 Unit Heater installed in a workshop. This image demonstrates the heater's application in a typical workspace, illustrating its heating flexibility for different environmental needs.

4.3 Air Circulation

The unit utilizes a low static pressure axial fan and power venting to ensure effective air circulation and minimize heat loss, distributing warmth evenly throughout the space.

5. പരിപാലനം

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-125 heater. Always disconnect power and gas supply before performing any maintenance.

  • വാർഷിക പരിശോധന: Have a qualified service technician inspect the heat exchanger, burner, ignition system, and venting system annually.
  • വൃത്തിയാക്കൽ: Keep the area around the heater clean and free of dust and debris. Periodically clean the fan blades and motor to ensure optimal airflow. The updated cabinet structure with a removable front face and hinged access door panel simplifies access for cleaning and service.
  • ഫിൽട്ടർ മാറ്റിസ്ഥാപിക്കൽ: If your installation includes an air filter, inspect and replace it regularly according to manufacturer recommendations.

6. പ്രശ്‌നപരിഹാരം

The integrated circuit board with a 7-segment display and status-indicating LED provides diagnostic codes to assist in troubleshooting. Refer to the specific diagnostic code chart in the full installation manual for detailed information.

സാധാരണ പ്രശ്‌നപരിഹാര സാഹചര്യങ്ങൾ
പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ഹീറ്റർ ഓണാക്കുന്നില്ല.No power, gas supply off, thermostat setting too low, safety lockout.Check power supply and disconnect switch. Ensure gas valve is open. Adjust thermostat. Check LED for lockout codes.
ഹീറ്റർ ഇടയ്ക്കിടെ ഓണും ഓഫും ആകാറുണ്ട്.Improper thermostat placement, restricted airflow, oversized unit.Relocate thermostat away from drafts or heat sources. Clear obstructions from air intake/output. Consult a professional.
ആവശ്യത്തിന് ചൂടാക്കൽ ഇല്ല.Low gas pressure, dirty burner, fan issues.Verify gas pressure. Clean burner. Inspect fan for proper operation. Contact service technician.

For complex issues or if diagnostic codes persist, contact a qualified HVAC service technician.

7 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
മോഡൽയുഡിഎക്സ്സി-125
ഹീറ്റ് ഔട്ട്പുട്ട്120,000 ബി.ടി.യു
ഇന്ധന തരംപ്രകൃതി വാതകം
താപ കാര്യക്ഷമത83% AFUE
ഇൻഡോർ/ഔട്ട്ഡോർ ഉപയോഗംഇൻഡോർ മാത്രം
മൗണ്ടിംഗ് തരംCeiling Mount, Wall Mount (mounting hardware sold separately)
ഉൽപ്പന്ന അളവുകൾ (D x W x H)34.28" x 27" x 24.75"
ഫാൻ തരംLow Static Propeller Fan
ചൂട് എക്സ്ചേഞ്ചർTCORE2 Titanium-Stabilized Aluminized Steel
പ്രത്യേക സവിശേഷതകൾFast Heating, Integrated Circuit Board with 7-Segment Display, Status-Indicating LED, Built-in Disconnect, Multi-Try Direct Spark Ignition, External Gas Connection, ETL Approved
Reznor UDXC-125 Unit Heater with dimensions labeled

Figure 4: Dimensions of the Reznor UDXC-125 Unit Heater. This image provides a visual representation of the heater's physical size, indicating its depth, width, and height.

8. വാറൻ്റിയും പിന്തുണയും

For warranty information, please refer to the documentation provided with your purchase or contact the seller, 1HVAC, directly. Keep your proof of purchase for warranty claims.

For technical support or service inquiries, please contact your authorized Reznor dealer or the point of purchase. Ensure you have your model number (UDXC-125) and serial number ready when contacting support.

അനുബന്ധ രേഖകൾ - യുഡിഎക്സ്സി-125

പ്രീview ഇലക്ട്രിക്, ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കുള്ള റെസ്‌നോർ സീലിംഗ് സസ്പെൻഷൻ കിറ്റ് ഇൻസ്റ്റലേഷൻ ഗൈഡ്
EHU ഇലക്ട്രിക്, UDXC, UDX, UDZ ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകളുമായി പൊരുത്തപ്പെടുന്ന Reznor CK22 സീലിംഗ് സസ്പെൻഷൻ കിറ്റിനായുള്ള ഇൻസ്റ്റലേഷൻ നിർദ്ദേശങ്ങളും ഘടക വിശദാംശങ്ങളും. നിങ്ങളുടെ Reznor ഹീറ്റർ എങ്ങനെ സുരക്ഷിതമായി ഘടിപ്പിക്കാമെന്ന് മനസിലാക്കുക.
പ്രീview ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കുള്ള റെസ്നോർ ഗ്യാസ് കൺവേർഷൻ കിറ്റ് ഇൻസ്റ്റാളേഷൻ
UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, UDBS എന്നിവയുൾപ്പെടെ വിവിധ ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്റർ മോഡലുകൾക്കായുള്ള റെസ്‌നോർ ഗ്യാസ് കൺവേർഷൻ കിറ്റുകൾക്കുള്ള ഇൻസ്റ്റാളേഷൻ നിർദ്ദേശങ്ങൾ ഈ പ്രമാണം നൽകുന്നു. ഉയർന്ന ഉയരത്തിലുള്ള ഇൻസ്റ്റാളേഷനുകൾക്കായുള്ള ഘടക തിരഞ്ഞെടുപ്പ്, സുരക്ഷാ മുൻകരുതലുകൾ, പ്രകൃതി വാതകത്തിനും പ്രൊപ്പെയ്നും ഇടയിൽ പരിവർത്തനം ചെയ്യുന്നതിനുള്ള ഇൻസ്റ്റലേഷൻ ഘട്ടങ്ങൾ എന്നിവ ഇതിൽ വിശദമായി പ്രതിപാദിക്കുന്നു.
പ്രീview മൾട്ടിപ്പിൾ യൂണിറ്റ് കൺട്രോളിനുള്ള റെസ്നോർ റിലേ കിറ്റ് ഇൻസ്റ്റലേഷൻ ഗൈഡ് (CL31/CL32)
Reznor CL31, CL32 റിലേ കിറ്റുകൾക്കായുള്ള സമഗ്രമായ ഇൻസ്റ്റലേഷൻ ഗൈഡ്, വിവിധ Reznor ഇലക്ട്രിക്, ഗ്യാസ്-ഫയർ ഹീറ്ററുകൾക്ക് ഒന്നിലധികം യൂണിറ്റ് നിയന്ത്രണം പ്രാപ്തമാക്കുന്നു. ഘടക ലിസ്റ്റുകൾ, വിശദമായ ഇൻസ്റ്റലേഷൻ ഘട്ടങ്ങൾ, വയറിംഗ് സ്പെസിഫിക്കേഷനുകൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview ഇലക്ട്രിക്, ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കുള്ള റെസ്‌നോർ സീലിംഗ് സസ്പെൻഷൻ കിറ്റ് ഇൻസ്റ്റാളേഷൻ (ഓപ്ഷൻ CK22)
EHU, UDX, UDXC, UDZ ഇലക്ട്രിക്, ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കായി രൂപകൽപ്പന ചെയ്‌തിരിക്കുന്ന Reznor CK22 സീലിംഗ് സസ്‌പെൻഷൻ കിറ്റിനായുള്ള ഇൻസ്റ്റലേഷൻ ഗൈഡ്. കിറ്റ് ഘടകങ്ങളും ഇൻസ്റ്റാളേഷൻ ഘട്ടങ്ങളും ഉൾപ്പെടുന്നു.
പ്രീview ഗ്യാസ്-ഫയർഡ് യൂണിറ്റ് ഹീറ്ററുകൾക്കുള്ള റെസ്നോർ വെർട്ടിക്കൽ ലൂവർ കിറ്റ് ഇൻസ്റ്റലേഷൻ ഗൈഡ് (OPT-CD1)
ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കായി (മോഡലുകൾ UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ) രൂപകൽപ്പന ചെയ്‌തിരിക്കുന്ന Reznor OPT-CD1 വെർട്ടിക്കൽ ലൂവർ കിറ്റിനുള്ള ഇൻസ്റ്റലേഷൻ നിർദ്ദേശങ്ങൾ. ഘടകങ്ങളുടെ പട്ടികയും ഘട്ടം ഘട്ടമായുള്ള അസംബ്ലി ഗൈഡും ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview റെസ്‌നോർ UBXC/UDXC ഗ്യാസ്-ഫയർഡ് യൂണിറ്റ് ഹീറ്റർ റീപ്ലേസ്‌മെന്റ് പാർട്‌സ് മാനുവൽ
റെസ്‌നോർ UBXC, UDXC സീരീസ് ഗ്യാസ്-ഫയർ യൂണിറ്റ് ഹീറ്ററുകൾക്കുള്ള വിശദമായ മാറ്റിസ്ഥാപിക്കൽ ഭാഗങ്ങൾ വിവരങ്ങൾ ഈ മാനുവലിൽ നൽകുന്നു. സീരിയൽ നമ്പർ ഡീകോഡിംഗ്, ഇലക്ട്രിക്കൽ ഘടകങ്ങൾ, ഫാൻ, മോട്ടോർ അസംബ്ലികൾ, ബ്ലോവർ അസംബ്ലികൾ, കാബിനറ്റ് ഘടകങ്ങൾ, ഹീറ്റ് എക്സ്ചേഞ്ചർ, ബർണർ അസംബ്ലികൾ, വെന്റർ, ഫ്ലൂ റാപ്പർ ഘടകങ്ങൾ, വിവിധ ആക്‌സസറികൾ, ഓപ്ഷനുകൾ എന്നിവയെക്കുറിച്ചുള്ള വിഭാഗങ്ങൾ ഇതിൽ ഉൾപ്പെടുന്നു.