System Sensor 2W-B

സിസ്റ്റം സെൻസർ 2W-B i3 സീരീസ് 2-വയർ ഫോട്ടോഇലക്ട്രിക് സ്മോക്ക് ഡിറ്റക്ടർ യൂസർ മാനുവൽ

Model: 2W-B

ആമുഖം

This manual provides comprehensive instructions for the proper installation, operation, and maintenance of your System Sensor 2W-B i3 Series 2-Wire Photoelectric Smoke Detector. Please read this manual thoroughly before installation and keep it for future reference.

ഫീച്ചറുകൾ

പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ

WARNING: This device is a smoke detector and not a fire alarm system. It is designed to detect smoke and provide a visual alert.

All life safety devices should be tested annually according to NFPA72 standards.

Do not paint the detector. Paint may interfere with the unit's ability to detect smoke.

This detector is not suitable for use in areas with high humidity or extreme temperatures outside the specified operating range.

സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

The System Sensor 2W-B i3 Series smoke detector features a plug-in design for easy installation.

അൺബോക്സിംഗും ഘടകങ്ങളും

Upon opening the package, you will find the smoke detector unit and an instruction guide. The detector consists of two main parts: the base, which connects to the wiring, and the detector head, which twists onto the base.

System Sensor 2W-B i3 Series Smoke Detector packaging and features

Image: Packaging of the System Sensor 2W-B i3 Series Smoke Detector, highlighting key features and certifications like UL and FM approval. The model number 2W-B is clearly visible.

വയറിംഗും മൗണ്ടിംഗും

This is a 2-wire system designed for 12/24 VDC power. Refer to the included wiring diagram in the instruction guide for specific connection details. The base plate should be securely mounted to the ceiling or wall.

Once the base is wired, align the detector head with the base and twist clockwise until it locks into place.

Note: Ensure power is disconnected before performing any wiring or installation.

ഓപ്പറേഷൻ

Once properly installed and powered, the detector will begin normal operation.

ഇൻഡിക്കേറ്റർ ലൈറ്റുകൾ

Installed System Sensor 2W-B i3 Series Smoke Detector on a ceiling

Image: A System Sensor 2W-B i3 Series Smoke Detector installed on a ceiling, showing its discreet profile and the green indicator light during normal operation.

വിപുലമായ കണ്ടെത്തൽ

The i3 Series incorporates drift compensation and smoothing algorithms to differentiate between actual smoke conditions and nuisance factors like dust or cooking fumes, reducing false alarms.

മെയിൻ്റനൻസ്

Regular maintenance is crucial for ensuring the continued reliability of your smoke detector.

വൃത്തിയാക്കൽ

The detector's cover and chamber are removable for easy cleaning. Gently vacuum or use a soft, damp cloth to remove dust and debris from the exterior and interior chamber. Do not use cleaning solvents.

ടെസ്റ്റിംഗ്

Test the detector monthly by pressing the test button or using approved smoke detector test spray. The red LED should illuminate, and the alarm should sound. If the alarm does not sound, replace the detector immediately.

Annual professional testing according to NFPA72 is recommended.

ട്രബിൾഷൂട്ടിംഗ്

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പച്ച LED ഇല്ലNo power or wiring issue.Check power supply and wiring connections. Consult a qualified electrician if necessary.
Frequent Nuisance AlarmsDetector location, dust accumulation, or environmental factors.Clean the detector chamber. Relocate the detector away from cooking fumes, high humidity, or dusty areas.
Red LED On, No SmokeDetector fault or sensitivity issue.Clean the detector. If the issue persists, the detector may need replacement.
Alarm Does Not Sound During TestDetector malfunction.Replace the detector immediately.

സ്പെസിഫിക്കേഷനുകൾ

വാറൻ്റിയും പിന്തുണയും

നിർമ്മാതാവിന്റെ വാറന്റി

This System Sensor 2W-B i3 Series Smoke Detector comes with a 3-year manufacturer's warranty. For warranty claims, please refer to the contact information provided in the original packaging or visit the manufacturer's webസൈറ്റ്.

സാങ്കേതിക സഹായം

For technical assistance or further inquiries, please contact System Sensor customer support.

ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ:

അനുബന്ധ രേഖകൾ - 2W-B

പ്രീview System Sensor i4 Series COSMO-2W & COSMO-4W Combination CO/Smoke Detector Wiring Diagrams
Detailed wiring diagrams and configuration guide for the System Sensor i4 Series COSMO-2W (2-wire) and COSMO-4W (4-wire) combination Carbon Monoxide and Photoelectric Smoke Detectors. Includes panel connections, module terminals, and DIP switch settings for fire alarm systems.
പ്രീview System Sensor 6424 Projected Beam Smoke Detector Technical Specification
Detailed technical specifications, features, applications, wiring diagrams, and mounting instructions for the System Sensor 6424 Projected Beam Smoke Detector, a 4-wire, 24 VDC infrared detector for large, high-ceiling areas.
പ്രീview System Sensor D2 Duct Smoke Detector: Installation and Maintenance Manual
This manual provides comprehensive installation, maintenance, and operational guidelines for the System Sensor D2 Duct Smoke Detector, designed for early smoke detection in HVAC systems. It details specifications, wiring, testing procedures, and troubleshooting.
പ്രീview System Sensor D2 Duct Smoke Detector: Installation and Maintenance Manual
This document provides detailed installation and maintenance instructions for the System Sensor D2 Duct Smoke Detector. It covers product specifications, installation procedures, testing, cleaning, and optional accessories for effective operation in HVAC systems.
പ്രീview RTS151KEYA Remote Test Station Installation and Maintenance Instructions
Installation and maintenance guide for the System Sensor RTS151KEYA Remote Test Station, detailing specifications, operation, wiring diagrams, and warranty information for fire detection systems.
പ്രീview സിസ്റ്റം സെൻസർ D4120 ഡക്റ്റ് സ്മോക്ക് ഡിറ്റക്ടർ ഇൻസ്റ്റാളേഷനും മെയിന്റനൻസ് മാനുവലും
സിസ്റ്റം സെൻസർ D4120 ഡക്റ്റ് സ്മോക്ക് ഡിറ്റക്ടറിനും D4S സെൻസർ ഘടകത്തിനുമുള്ള സമഗ്രമായ ഇൻസ്റ്റാളേഷനും പരിപാലന ഗൈഡും, സ്പെസിഫിക്കേഷനുകൾ, വയറിംഗ്, ടെസ്റ്റിംഗ്, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.