Aquatec 5851-7E12-J574

Aquatec DDP 5800 RO Delivery Demand Pump User Manual

ആമുഖം

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Aquatec DDP 5800 RO Delivery Demand Pump. Please read these instructions thoroughly before beginning installation or operation to ensure proper function and longevity of the product. The Aquatec DDP 5800 is designed to enhance the performance of tank-based reverse osmosis (RO) systems by increasing water pressure and ensuring consistent flow.

പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ

മുന്നറിയിപ്പ്: Failure to follow these safety instructions could result in electric shock, fire, serious injury, or property damage.

ഉൽപ്പന്നം കഴിഞ്ഞുview കൂടാതെ പ്രധാന സവിശേഷതകൾ

The Aquatec DDP 5800 is a high-performance demand pump designed to optimize your reverse osmosis system. It ensures consistent water pressure and flow, even when the incoming city water pressure is low.

Aquatec DDP 5800 RO Delivery Demand Pump and packaging

Image: The Aquatec DDP 5800 pump shown alongside its product packaging, highlighting its compact design and included power cord.

Aquatec DDP 5800 pump with key specifications

Image: A close-up of the Aquatec DDP 5800 pump, detailing its specifications such as 0.7 GPM flow, 60 PSI pressure, and 115 VAC operation, along with push-to-connect ports for 3/8-inch tubing.

പ്രധാന സവിശേഷതകൾ:

No sound icon over Aquatec pump

Image: An icon indicating quiet operation, superimposed over a portion of the Aquatec DDP 5800 pump, emphasizing its low noise output.

Diagram showing water flow, pressure detection, and pump activation

Image: A diagram illustrating the pump's on-demand functionality: water flow leads to pressure detection, which then triggers pump activation.

സാങ്കേതിക സവിശേഷതകൾ

സ്പെസിഫിക്കേഷൻവിശദാംശങ്ങൾ
മോഡൽ നമ്പർ5851-7E12-J574
നിർമ്മാതാവ്Aquatec
വിതരണക്കാരൻESP Water Products
പരമാവധി ഒഴുക്ക് നിരക്ക്മിനിറ്റിൽ 0.7 ഗാലൺസ് (GPM)
പ്രവർത്തന സമ്മർദ്ദം70 PSI (Pump Output), 60 PSI (Pressure Switch)
വാല്യംtage120 വോൾട്ട് എസി
നിലവിലുള്ളത്0.3 Amps @ 60 PSI
പവർ ഉറവിടംകോർഡഡ് ഇലക്ട്രിക്
കണക്ഷനുകൾ3/8-inch Quick Connect Ports
മെറ്റീരിയൽPolypropylene (PP), Stainless Steel
ഉൽപ്പന്ന അളവുകൾ (L x W x H)7.51" x 3.6" x 3.38"
ഇനത്തിൻ്റെ ഭാരം6.25 പൗണ്ട്
ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾPower Cord (6-foot, 3-prong plug)

സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

The Aquatec DDP 5800 is designed for straightforward installation. Most users can mount the pump and connect tubing themselves. However, for any hard wiring or code-related electrical work, it is recommended to consult a qualified electrician.

ഇൻസ്റ്റലേഷൻ ഘട്ടങ്ങൾ:

  1. ഒരു ലൊക്കേഷൻ തിരഞ്ഞെടുക്കുക: Select a dry, stable location near your RO system and a 115 VAC power outlet. Ensure adequate ventilation.
  2. Mount the Pump: Securely mount the pump using appropriate hardware (not included) to prevent vibration and movement.
  3. ട്യൂബുകൾ ബന്ധിപ്പിക്കുക: The pump features 3/8-inch push-to-connect ports. Ensure your RO system uses 3/8" OD tubing. If 1/4" tubing is used, a reducing fitting (sold separately) will be required.
    • Connect the outlet of your RO storage tank (or post-filter) to the pump's inlet port.
    • Connect the pump's outlet port to your RO faucet or other dispensing point.
    • Ensure all connections are firm and leak-free.
  4. ഇലക്ട്രിക്കൽ കണക്ഷൻ: Plug the 6-foot power cord into a grounded 115 VAC outlet. The pump includes a 60 PSI pressure switch for automatic operation.
  5. സിസ്റ്റം പരിശോധന: After installation, slowly turn on the water supply to the RO system and check for any leaks. Allow the RO tank to fill completely before operating the pump.
Aquatec 5800 Pump Installation Diagram

Image: A diagram illustrating the typical installation of the Aquatec DDP 5800 pump within an under-sink reverse osmosis system, showing connections to the RO filters, storage tank, and faucet.

Hand connecting tubing to a quick-connect port on the pump

Image: A hand demonstrating the simple push-to-connect method for attaching tubing to the pump, highlighting the ease of installation.

പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The Aquatec DDP 5800 pump operates automatically based on demand from your RO system. Once properly installed and connected to power, it will activate when water is drawn from the RO faucet and the pressure drops below the set point of the internal pressure switch (approximately 60 PSI).

മെയിൻ്റനൻസ്

The Aquatec DDP 5800 pump is designed for reliable, low-maintenance operation. Regular checks can help ensure its continued performance.

For any internal maintenance or repairs, it is recommended to contact qualified service personnel or the manufacturer.

പ്രശ്ന പരിഹാരത്തിന് സഹായിക്കുന്ന മാർഗധർശി

This section provides solutions to common issues you might encounter with your Aquatec DDP 5800 pump. Always disconnect power before inspecting the pump.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പമ്പ് ഓണാക്കുന്നില്ല.No power; faulty power cord/outlet; pressure switch not activating.Check power connection and outlet. Ensure RO faucet is open and water is being drawn. Verify pressure switch functionality.
കുറഞ്ഞ ജലപ്രവാഹം അല്ലെങ്കിൽ മർദ്ദം.Clogged RO filters; kinked/blocked tubing; insufficient inlet pressure; pump malfunction.Replace RO filters if due. Inspect tubing for obstructions. Ensure adequate water supply to the RO system. Contact support if pump is suspected faulty.
പമ്പ് തുടർച്ചയായി പ്രവർത്തിക്കുന്നു.Leak in the system; faulty pressure switch; RO tank not fully pressurized.Check all connections for leaks. Ensure RO tank is fully charged. If problem persists, pressure switch may need replacement or adjustment (contact support).
അസാധാരണമായ ശബ്ദം അല്ലെങ്കിൽ വൈബ്രേഷൻ.Loose mounting; air in the lines; internal component issue.Ensure pump is securely mounted. Bleed air from the system by running water for a few minutes. If noise persists, contact support.

വാറൻ്റിയും ഉപഭോക്തൃ പിന്തുണയും

For warranty information, technical assistance, or to purchase replacement parts, please contact ESP Water Products, the authorized distributor, or Aquatec directly.

അനുബന്ധ രേഖകൾ - 5851-7E12-J574

പ്രീview Aquatec DDP Series Delivery/Demand Pump Installation & Operation Guide
Operational and installation guidelines for Aquatec DDP Series Delivery/Demand Pumps (Models 550, 5800, 7800). Covers safety precautions, mounting, plumbing, electrical setup, and maintenance recommendations.
പ്രീview അക്വാടെക് ബാത്ത്ലിഫ്റ്റ് സക്ഷൻ കപ്പ് മൗണ്ടിംഗ് നിർദ്ദേശങ്ങൾ
അക്വാടെക് ബാത്ത്‌ലിഫ്റ്റിനുള്ള സക്ഷൻ കപ്പുകൾ എങ്ങനെ മൌണ്ട് ചെയ്യാം എന്നതിനെക്കുറിച്ചുള്ള ഘട്ടം ഘട്ടമായുള്ള ഗൈഡ്, മുന്നിലും പിന്നിലും സക്ഷൻ കപ്പ് ഇൻസ്റ്റാളേഷൻ ഉൾപ്പെടെ.
പ്രീview അക്വാടെക് ORCA പെൽവിക്/ചെസ്റ്റ് ബെൽറ്റ് അസംബ്ലി നിർദ്ദേശങ്ങൾ
അക്വാടെക് ORCA പെൽവിക് ബെൽറ്റിനും ചെസ്റ്റ് ബെൽറ്റിനുമുള്ള അസംബ്ലി നിർദ്ദേശങ്ങൾ, ഡെലിവറി വ്യാപ്തി, സുരക്ഷാ മുൻകരുതലുകൾ, ഘട്ടം ഘട്ടമായുള്ള ഇൻസ്റ്റാളേഷൻ ഗൈഡ് എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview Aquatec Pure Cala Raised Toilet Seat User Manual
User manual for the Aquatec Pure Cala raised toilet seat by Invacare. Provides instructions on setup, maintenance, safety, and intended use for enhanced accessibility and comfort.
പ്രീview Aquatec Pure Cala Soft Cushion Installation Guide
Step-by-step instructions for installing the Aquatec Pure Cala Soft Cushion. Learn how to attach the soft toilet seat riser for enhanced comfort and accessibility.
പ്രീview Aquatec Water & Garden Catalogue 2025/2026 | Oase & PondMAX Solutions
Explore the Aquatec Equipment Water & Garden Catalogue 2025/2026, featuring Oase, PondMAX, and Otterbine products for ponds, fountains, aquariums, and lake management. Find pumps, filters, water features, and more.