ആമുഖം
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Aquatec DDP 5800 RO Delivery Demand Pump. Please read these instructions thoroughly before beginning installation or operation to ensure proper function and longevity of the product. The Aquatec DDP 5800 is designed to enhance the performance of tank-based reverse osmosis (RO) systems by increasing water pressure and ensuring consistent flow.
പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ
മുന്നറിയിപ്പ്: Failure to follow these safety instructions could result in electric shock, fire, serious injury, or property damage.
- Always disconnect power before performing any service or maintenance on the pump.
- Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures.
- Do not use the pump with flammable liquids or in explosive atmospheres.
- The pump is designed for use with potable water only.
- Any hard wiring or code-related electrical work should be performed by a qualified electrician.
- വൈദ്യുതി വിതരണം വോളിയം ആണെന്ന് പരിശോധിക്കുകtage matches the pump's requirements (120V).
- ചോർച്ച തടയാൻ എല്ലാ പ്ലംബിംഗ് കണക്ഷനുകളും സുരക്ഷിതമാണെന്ന് ഉറപ്പാക്കുക.
ഉൽപ്പന്നം കഴിഞ്ഞുview കൂടാതെ പ്രധാന സവിശേഷതകൾ
The Aquatec DDP 5800 is a high-performance demand pump designed to optimize your reverse osmosis system. It ensures consistent water pressure and flow, even when the incoming city water pressure is low.

Image: The Aquatec DDP 5800 pump shown alongside its product packaging, highlighting its compact design and included power cord.

Image: A close-up of the Aquatec DDP 5800 pump, detailing its specifications such as 0.7 GPM flow, 60 PSI pressure, and 115 VAC operation, along with push-to-connect ports for 3/8-inch tubing.
പ്രധാന സവിശേഷതകൾ:
- On-Demand Operation: Increases water pressure for RO systems when city water pressure is insufficient, activating only when needed.
- ഉയർന്ന ഒഴുക്ക് നിരക്ക്: Delivers a consistent 0.7 GPM (Gallons Per Minute) for efficient water filtration.
- വിശ്വസനീയമായ പ്രകടനം: Features a durable 3-chamber diaphragm pump design, producing 70 PSI for optimal water delivery.
- Quiet & Compact: Designed to operate quietly and fit seamlessly with most RO systems, ensuring a peaceful environment.
- ഊർജ്ജ കാര്യക്ഷമത: Utilizes a high-efficiency, permanent-magnet 3-chamber diaphragm design and a built-in pressure switch, reducing power consumption by running only on demand.
- താപനില റേറ്റിംഗ്: Rated for water temperatures up to 140°F (60°C), though primarily intended for room-temperature/cold RO or drinking water. Not for continuous hot-water recirculation.
- അനുയോജ്യത: Compatible with most tank-based RO systems as a post-tank delivery pump, provided the line uses 3/8" OD tubing (or 1/4" with reducing fitting, sold separately), inlet pressure is up to 60 PSI, and a 115 VAC outlet is available.

Image: An icon indicating quiet operation, superimposed over a portion of the Aquatec DDP 5800 pump, emphasizing its low noise output.

Image: A diagram illustrating the pump's on-demand functionality: water flow leads to pressure detection, which then triggers pump activation.
സാങ്കേതിക സവിശേഷതകൾ
| സ്പെസിഫിക്കേഷൻ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ നമ്പർ | 5851-7E12-J574 |
| നിർമ്മാതാവ് | Aquatec |
| വിതരണക്കാരൻ | ESP Water Products |
| പരമാവധി ഒഴുക്ക് നിരക്ക് | മിനിറ്റിൽ 0.7 ഗാലൺസ് (GPM) |
| പ്രവർത്തന സമ്മർദ്ദം | 70 PSI (Pump Output), 60 PSI (Pressure Switch) |
| വാല്യംtage | 120 വോൾട്ട് എസി |
| നിലവിലുള്ളത് | 0.3 Amps @ 60 PSI |
| പവർ ഉറവിടം | കോർഡഡ് ഇലക്ട്രിക് |
| കണക്ഷനുകൾ | 3/8-inch Quick Connect Ports |
| മെറ്റീരിയൽ | Polypropylene (PP), Stainless Steel |
| ഉൽപ്പന്ന അളവുകൾ (L x W x H) | 7.51" x 3.6" x 3.38" |
| ഇനത്തിൻ്റെ ഭാരം | 6.25 പൗണ്ട് |
| ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾ | Power Cord (6-foot, 3-prong plug) |
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
The Aquatec DDP 5800 is designed for straightforward installation. Most users can mount the pump and connect tubing themselves. However, for any hard wiring or code-related electrical work, it is recommended to consult a qualified electrician.
ഇൻസ്റ്റലേഷൻ ഘട്ടങ്ങൾ:
- ഒരു ലൊക്കേഷൻ തിരഞ്ഞെടുക്കുക: Select a dry, stable location near your RO system and a 115 VAC power outlet. Ensure adequate ventilation.
- Mount the Pump: Securely mount the pump using appropriate hardware (not included) to prevent vibration and movement.
- ട്യൂബുകൾ ബന്ധിപ്പിക്കുക: The pump features 3/8-inch push-to-connect ports. Ensure your RO system uses 3/8" OD tubing. If 1/4" tubing is used, a reducing fitting (sold separately) will be required.
- Connect the outlet of your RO storage tank (or post-filter) to the pump's inlet port.
- Connect the pump's outlet port to your RO faucet or other dispensing point.
- Ensure all connections are firm and leak-free.
- ഇലക്ട്രിക്കൽ കണക്ഷൻ: Plug the 6-foot power cord into a grounded 115 VAC outlet. The pump includes a 60 PSI pressure switch for automatic operation.
- സിസ്റ്റം പരിശോധന: After installation, slowly turn on the water supply to the RO system and check for any leaks. Allow the RO tank to fill completely before operating the pump.

Image: A diagram illustrating the typical installation of the Aquatec DDP 5800 pump within an under-sink reverse osmosis system, showing connections to the RO filters, storage tank, and faucet.

Image: A hand demonstrating the simple push-to-connect method for attaching tubing to the pump, highlighting the ease of installation.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The Aquatec DDP 5800 pump operates automatically based on demand from your RO system. Once properly installed and connected to power, it will activate when water is drawn from the RO faucet and the pressure drops below the set point of the internal pressure switch (approximately 60 PSI).
- Ensure the RO system's water supply is open and the storage tank is adequately filled.
- When you open your RO faucet, the pump will sense the pressure drop and automatically turn on to deliver pressurized water.
- When the faucet is closed, the pressure in the line will increase, and the pump's internal pressure switch will automatically turn the pump off.
- The pump is designed for intermittent use, running only when water is being dispensed.
മെയിൻ്റനൻസ്
The Aquatec DDP 5800 pump is designed for reliable, low-maintenance operation. Regular checks can help ensure its continued performance.
- വിഷ്വൽ പരിശോധന: Periodically inspect the pump and all connections for any signs of leaks, corrosion, or damage.
- ശുചിത്വം: Keep the pump exterior clean and free from dust or debris to ensure proper ventilation.
- Tubing Integrity: Check tubing for kinks, cracks, or wear that could affect water flow or cause leaks.
- പവർ കോർഡ്: പവർ കോർഡ് കേടായിട്ടില്ലെന്ന് ഉറപ്പാക്കുക.
- Filter Changes: While not directly part of pump maintenance, ensure your RO system filters are changed according to the manufacturer's recommendations to prevent strain on the pump.
For any internal maintenance or repairs, it is recommended to contact qualified service personnel or the manufacturer.
പ്രശ്ന പരിഹാരത്തിന് സഹായിക്കുന്ന മാർഗധർശി
This section provides solutions to common issues you might encounter with your Aquatec DDP 5800 pump. Always disconnect power before inspecting the pump.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| പമ്പ് ഓണാക്കുന്നില്ല. | No power; faulty power cord/outlet; pressure switch not activating. | Check power connection and outlet. Ensure RO faucet is open and water is being drawn. Verify pressure switch functionality. |
| കുറഞ്ഞ ജലപ്രവാഹം അല്ലെങ്കിൽ മർദ്ദം. | Clogged RO filters; kinked/blocked tubing; insufficient inlet pressure; pump malfunction. | Replace RO filters if due. Inspect tubing for obstructions. Ensure adequate water supply to the RO system. Contact support if pump is suspected faulty. |
| പമ്പ് തുടർച്ചയായി പ്രവർത്തിക്കുന്നു. | Leak in the system; faulty pressure switch; RO tank not fully pressurized. | Check all connections for leaks. Ensure RO tank is fully charged. If problem persists, pressure switch may need replacement or adjustment (contact support). |
| അസാധാരണമായ ശബ്ദം അല്ലെങ്കിൽ വൈബ്രേഷൻ. | Loose mounting; air in the lines; internal component issue. | Ensure pump is securely mounted. Bleed air from the system by running water for a few minutes. If noise persists, contact support. |
വാറൻ്റിയും ഉപഭോക്തൃ പിന്തുണയും
For warranty information, technical assistance, or to purchase replacement parts, please contact ESP Water Products, the authorized distributor, or Aquatec directly.
- നിർമ്മാതാവ്: Aquatec
- വിതരണക്കാരൻ: ESP Water Products
- Refer to your purchase documentation for specific warranty terms and contact details.