ആമുഖം
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.
ഘടകങ്ങൾ ഉൾപ്പെടുത്തിയിട്ടുണ്ട്
- Indoor Wall Mounted Air Handler Unit
- Outdoor Mini Split Heat Pump Condenser
- Line Set (30-foot length, 1/4 x 3/8 copper lines)
- കൺട്രോൾ വയർ
- Wall Mount Bracket (18 1/4" Length)
- Line Cover Guards
- Drain Tube (20-foot)
- വയർലെസ് റിമോട്ട് കൺട്രോൾ

ചിത്രം 1: ഓവർview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.
ഇൻസ്റ്റലേഷൻ പരിഗണനകൾ
Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

ചിത്രം 2: വിശദമായി view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.
Basic Operation Modes
- കൂളിംഗ് മോഡ്: Reduces room temperature to the desired setting.
- ചൂടാക്കൽ മോഡ്: Increases room temperature to the desired setting.
- ഫാൻ മോഡ്: ചൂടാക്കുകയോ തണുപ്പിക്കുകയോ ചെയ്യാതെ വായു സഞ്ചാരം നടത്തുന്നു.
- ഡ്രൈ മോഡ് (ഡീഹ്യുമിഡിഫിക്കേഷൻ): മുറിയിലെ ഈർപ്പം കുറയ്ക്കുന്നു.
- യാന്ത്രിക മോഡ്: Automatically selects heating or cooling based on the set temperature and current room temperature.
പ്രധാന സവിശേഷതകളും നിയന്ത്രണങ്ങളും
- Wireless Backlight Remote Control: Allows convenient adjustment of settings from anywhere in the room.
- Auto-Restart After Power Failure: The unit will automatically resume operation with previous settings after a power outage.
- Self-Diagnosis with Digital Display: Provides error codes on the digital display for easier troubleshooting.
- Adjustable LED Display ON/OFF: Control the visibility of the unit's LED display.
- Power Saving Sleep Mode Set-up: Optimizes temperature and fan speed for comfortable sleep while conserving energy.

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.
മെയിൻ്റനൻസ്
Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.
ഫിൽട്ടർ ക്ലീനിംഗ്
The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.
Drain Pan Maintenance
The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.
യൂണിറ്റ് ക്ലീനിംഗ്
The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.
ട്രബിൾഷൂട്ടിംഗ്
Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| യൂണിറ്റ് ഓണാക്കുന്നില്ല | No power, remote control batteries low, unit switch off. | Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged. |
| ആവശ്യത്തിന് ചൂടാക്കൽ/തണുപ്പിക്കൽ ഇല്ല | Dirty air filters, blocked outdoor unit, incorrect mode/temperature setting, refrigerant leak. | Clean filters, clear obstructions from outdoor unit, verify settings, contact professional for refrigerant check. |
| അസാധാരണമായ ശബ്ദം | അയഞ്ഞ ഭാഗങ്ങൾ, ഫാൻ തടസ്സം, റഫ്രിജറന്റ് പ്രവാഹ ശബ്ദം (സാധാരണ). | Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service. |
| ഇൻഡോർ യൂണിറ്റിൽ നിന്ന് വെള്ളം ചോർന്നൊലിക്കുന്നു | Clogged drain pan/tube, improper installation. | Clean drain pan and tube. If issue persists, professional inspection is required. |
| Digital display shows error code | Internal system fault. | Note the error code and consult the full product manual or contact customer support for specific guidance. |
For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.
സ്പെസിഫിക്കേഷനുകൾ
Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).
| ആട്രിബ്യൂട്ട് | മൂല്യം |
|---|---|
| ബ്രാൻഡ് നാമം | എസിക്യു |
| മോഡൽ വിവരം | RXNG09AXVJU / FTXNG09AXVJU |
| BTU Capacity (Cooling) | 9,000 ബി.ടി.യു. (0.75 ടൺ) |
| BTU Capacity (Heating) | 4,400 BTU – 13,000 BTU |
| SEER2 കാര്യക്ഷമത | 18 SEER2 |
| വാല്യംtage | 208/230 Volts, 1 Phase, 60Hz |
| ശബ്ദ നില (ഔട്ട്ഡോർ യൂണിറ്റ്) | 56 ഡി.ബി |
| ഇൻസ്റ്റലേഷൻ തരം | സ്പ്ലിറ്റ് സിസ്റ്റം |
| ഫോം ഫാക്ടർ | മിനി-സ്പ്ലിറ്റ് |
| റഫ്രിജറൻ്റ് | R 410A |
| ശുപാർശ ചെയ്യുന്ന കവറേജ് ഏരിയ | 400 ചതുരശ്ര അടി വരെ |

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.
വാറൻ്റിയും പിന്തുണയും
For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.
For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.
ഓൺലൈൻ ഉറവിടങ്ങൾ: For additional resources, FAQs, and product registration, visit the ACiQ Store on Amazon.