1. ആമുഖം
This manual provides comprehensive instructions for the installation, operation, and maintenance of your ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System. Please read this manual thoroughly before installation and operation to ensure proper function and safety.
The ACiQ Inverter Heat Pump System is designed for high efficiency heating and cooling, adapting its output to meet changing weather conditions. It includes an inverter heat pump, a multi-positional cased evaporator coil, and a complete installation kit.
2 സുരക്ഷാ വിവരങ്ങൾ
Always adhere to local and national electrical and building codes. Installation and servicing should only be performed by qualified personnel.
- ഇലക്ട്രിക്കൽ സുരക്ഷ: Disconnect all power before servicing. Ensure proper grounding.
- റഫ്രിജറന്റ് കൈകാര്യം ചെയ്യൽ: Only certified technicians should handle refrigerants.
- വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ (PPE): Wear appropriate PPE, including gloves and eye protection, during installation and maintenance.
- ഭാരം: Components can be heavy. Use proper lifting techniques or seek assistance.
3. സിസ്റ്റം ഘടകങ്ങൾ
The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System includes the following main components:
- Inverter Heat Pump: Converts AC power to DC, adjusting compressor speed and BTU output.
- ബാഷ്പീകരണ കോയിൽ: Cased multi-positional coil with factory-integrated TXV kit.
- ഇൻസ്റ്റാളേഷൻ കിറ്റ്: Includes Cielo Smart Thermostat, 50' insulated line set, 1/2" x 6' 10-gauge electrical whip, 60A non-fused disconnect switch, ICM Controls Surge Protector, CPS Charging Adapter, Wall Sleeve, and Wall Mount Bracket.

ചിത്രം 3.1: ഓവർview of the ACiQ Heat Pump System components, including the outdoor unit, indoor coil, thermostat, and various installation accessories.

ചിത്രം 3.2: വിശദമായി view of the complete installation kit, showing the line set, electrical whip, disconnect switch, surge protector, and smart thermostat.
4 സ്പെസിഫിക്കേഷനുകൾ
4.1. Heat Pump Condenser Specifications
- Summer Cooling Control: 36,000 BTU/H cooling precision
- Winter Warmth Control: 36,000 to 35,000 BTU/H heating power
- ഊർജ്ജ കാര്യക്ഷമത: Up to 14.4 SEER (9.30 EER2) performance
- Summer Proof Cooling: 5°F to 122°F outdoor temp operation
- Winter Proof Heating: 5°F to 75°F outdoor temp operation
- കണ്ടൻസർ കോയിൽ: Gold fin for durability
- പ്രവർത്തനം: Quietest operation at maximum workloads

Figure 4.1: Visual representation of the heat pump condenser and its key specifications.
4.2. Evaporator Coil Specifications
- എയർ ഫ്ലോ: 1058.82 CFM
- സമ്മർദ്ദം: 0.28 In. wg.
- നിർജ്ജലീകരണം: 4.64
- അളവ് (W x D x H): 21.52 x 20.98 x 23.58 ഇഞ്ച് (547 x 533 x 599 മിമി)
- Packing (W x D x H): 23.47 x 26.18 x 25.39 ഇഞ്ച് (596 x 665 x 645 മിമി)
- മൊത്തം/മൊത്ത ഭാരം: 62.19 / 71.00 lbs (28.20 / 32.20 kg)
Note: The coil is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

ചിത്രം 4.2: വിശദമായി view of the evaporator coil with its dimensions and performance metrics.
4.3. മൊത്തത്തിലുള്ള അളവുകൾ

Figure 4.3: Overall dimensions of the outdoor heat pump unit and the evaporator coil.
5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.
5.1 പ്രീ-ഇൻസ്റ്റലേഷൻ ചെക്ക്ലിസ്റ്റ്
- എല്ലാ ഘടകങ്ങളും ഉണ്ടെന്നും കേടുപാടുകൾ സംഭവിച്ചിട്ടില്ലെന്നും ഉറപ്പാക്കുക.
- Ensure proper electrical supply is available (voltage, ampകോപം).
- Confirm adequate space for both indoor and outdoor units, allowing for proper airflow and service access.
- Review local building codes and obtain necessary permits.
5.2. Outdoor Unit Placement
Place the outdoor unit on a level, stable surface, away from obstructions that could impede airflow. Ensure sufficient clearance around the unit for maintenance and proper operation.

ചിത്രം 5.1: ഉദാample of an outdoor unit installed on a wall mount bracket, demonstrating proper clearance.
5.3. Evaporator Coil Installation
The evaporator coil is multi-positional. Install it in conjunction with a gas furnace or modular blower. Ensure proper drainage for condensate.
5.4. Line Set and Electrical Connections
- Connect the insulated line set between the outdoor unit and the evaporator coil. Ensure proper flaring and torque.
- Install the electrical whip and disconnect switch according to electrical codes.
- Connect the ICM Controls Surge Protector for electrical protection.
5.5 തെർമോസ്റ്റാറ്റ് ഇൻസ്റ്റാളേഷൻ
Install the Cielo Smart Thermostat according to its dedicated instructions. This thermostat allows for app control and integration with smart home systems like Alexa, Google Home, Siri, SmartThings, and IFTTT.

Figure 5.2: Diagram illustrating the features and connectivity options of the Cielo Smart Thermostat.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed, the system can be operated via the Cielo Smart Thermostat or its associated mobile application.
6.1. അടിസ്ഥാന പ്രവർത്തനം
- പവർ ഓൺ: Ensure the disconnect switch is in the ON position.
- മോഡ് തിരഞ്ഞെടുക്കൽ: Use the thermostat to select operating modes: Cooling, Heating, Fan Only, or Auto.
- താപനില ക്രമീകരണം: തെർമോസ്റ്റാറ്റ് നിയന്ത്രണങ്ങൾ ഉപയോഗിച്ച് ആവശ്യമുള്ള താപനില ക്രമീകരിക്കുക.
6.2. Smart Thermostat Features
The Cielo Smart Thermostat offers advanced features for enhanced comfort and energy savings:
- ഷെഡ്യൂളിംഗ്: Program daily or weekly schedules to optimize energy use.
- വിദൂര ആക്സസ്: Control your system from anywhere using the mobile app.
- ശബ്ദ നിയന്ത്രണം: Integrate with Amazon Alexa, Google Assistant, or Apple Siri for hands-free control.
- സ്മാർട്ട് ഹോം ഇൻ്റഗ്രേഷൻ: Connect with SmartThings and IFTTT for advanced automation.
7. പരിപാലനം
Regular maintenance is crucial for optimal performance and longevity of your ACiQ system. It is recommended to have a qualified technician perform annual inspections.
7.1. ഉപയോക്തൃ പരിപാലനം
- എയർ ഫിൽറ്റർ മാറ്റിസ്ഥാപിക്കൽ: Check and replace air filters monthly or as needed, especially during peak usage seasons.
- ഔട്ട്ഡോർ യൂണിറ്റ് വൃത്തിയാക്കൽ: Keep the area around the outdoor unit clear of debris, leaves, and obstructions. Gently clean the exterior coils with a soft brush and water if necessary.
- കണ്ടൻസേറ്റ് ഡ്രെയിൻ: Periodically check the condensate drain line for clogs and ensure proper drainage.
7.2. Professional Maintenance
An annual professional tune-up typically includes:
- Refrigerant level check and adjustment.
- Coil cleaning (indoor and outdoor).
- Electrical connection inspection and tightening.
- Blower motor and fan inspection.
- Thermostat calibration.
8. പ്രശ്നപരിഹാരം
This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact a qualified HVAC technician.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| സിസ്റ്റം ഓൺ ആകുന്നില്ല | No power, tripped breaker, thermostat issue | Check disconnect switch, reset breaker, ensure thermostat is powered and set correctly. |
| ആവശ്യത്തിന് ചൂടാക്കൽ/തണുപ്പിക്കൽ ഇല്ല | Dirty air filter, blocked outdoor unit, low refrigerant, incorrect thermostat setting | Replace air filter, clear obstructions from outdoor unit, check thermostat settings. Contact technician for refrigerant issues. |
| അസാധാരണമായ ശബ്ദങ്ങൾ | Loose parts, fan obstruction, compressor issue | അയഞ്ഞ പാനലുകളോ അവശിഷ്ടങ്ങളോ പരിശോധിക്കുക. ശബ്ദം തുടരുകയാണെങ്കിൽ, ഒരു ടെക്നീഷ്യനെ ബന്ധപ്പെടുക. |
| ഇൻഡോർ യൂണിറ്റിൽ നിന്ന് വെള്ളം ഒഴുകുന്നു | Clogged condensate drain line, frozen evaporator coil | Clear drain line. If coil is frozen, turn off system and allow to thaw, then check airflow. Contact technician if issue persists. |
9. വാറൻ്റി വിവരങ്ങൾ
The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System comes with a comprehensive warranty:
- ഭാഗങ്ങൾ: 7-year warranty on parts.
- കംപ്രസർ: കംപ്രസ്സറിന് 12 വർഷത്തെ വാറന്റി.
വാറൻ്റി വ്യവസ്ഥകൾ: The warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records.
10. പിന്തുണയും സമ്പർക്കവും
For technical support, warranty claims, or service inquiries, please contact ACiQ customer service or visit our official webസൈറ്റ്.
ACiQ Official Webസൈറ്റ്: Visit the ACiQ Store on Amazon
Please have your model number (B0D522DYZ7) and purchase date ready when contacting support.