This manual provides comprehensive instructions for the safe and efficient operation, maintenance, and troubleshooting of your Pulsar GD240N portable inverter generator. Please read this manual thoroughly before operating the generator to ensure proper usage and longevity of the product.

പ്രധാന സവിശേഷതകൾ:

സുരക്ഷാ വിവരങ്ങൾ

അപകടം: കാർബൺ മോണോക്സൈഡ് അപകടം

Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH. Operate in well-ventilated, outdoor areas away from open windows or doors. Point exhaust away from occupied areas. Do not run generator in enclosed areas (e.g., not in house or garage). Move to fresh air and get medical help if sick, dizzy, or weak.

Always ensure the generator is placed on a level surface and away from any flammable materials. Keep children and pets away from the operating unit.

പാക്കേജ് ഉള്ളടക്കം

Your Pulsar GD240N generator package includes the following items:

സജ്ജമാക്കുക

എഞ്ചിൻ ഓയിൽ ചേർക്കുന്നു

Before starting the generator for the first time, you must add engine oil. The generator is shipped without oil.

  1. Locate the oil fill cap on the side of the generator.
  2. Remove the side panel by unscrewing the two screws.
  3. ഓയിൽ ഫിൽ ക്യാപ്/ഡിപ്സ്റ്റിക്ക് നീക്കം ചെയ്യുക.
  4. Using the provided funnel, carefully add 5W-30 engine oil until it reaches the upper mark on the dipstick. The oil capacity is approximately 0.33 - 0.35 US Quarts (11.2 oz).
  5. Replace the oil fill cap and secure the side panel.
Adding engine oil to Pulsar GD240N generator

Image: Locating the oil fill cap and adding 5W-30 engine oil to the Pulsar GD240N inverter generator.

ഇന്ധനം ചേർക്കുന്നു

87 അല്ലെങ്കിൽ അതിൽ കൂടുതൽ ഒക്ടേൻ റേറ്റിംഗുള്ള, പുതിയതും ലെഡില്ലാത്തതുമായ ഗ്യാസോലിൻ മാത്രം ഉപയോഗിക്കുക. E85 ഇന്ധനം ഉപയോഗിക്കരുത്.

  1. ജനറേറ്റർ ഒരു നിരപ്പായ പ്രതലത്തിലാണെന്നും എഞ്ചിൻ ഓഫാക്കി തണുപ്പിച്ചിട്ടുണ്ടെന്നും ഉറപ്പാക്കുക.
  2. ഇന്ധന തൊപ്പി അഴിക്കുക.
  3. Carefully fill the fuel tank (capacity 1.18 Gallons) with gasoline, leaving a small air gap at the top to allow for fuel expansion.
  4. ഇന്ധന തൊപ്പി സുരക്ഷിതമായി മാറ്റിസ്ഥാപിക്കുക.

നിയന്ത്രിക്കുന്നുview

Familiarize yourself with the control panel located on the front of the generator:

Pulsar GD240N generator control panel with various outlets and switches

ചിത്രം: വിശദമായത് view of the Pulsar GD240N control panel, showing AC outlets, USB ports, DC 12V outlet, and various switches and indicator lights.

പ്രവർത്തന നിർദ്ദേശങ്ങൾ

ജനറേറ്റർ ആരംഭിക്കുന്നു

  1. Ensure the generator has sufficient oil and fuel.
  2. ഇന്ധന വാൽവ് 'ഓൺ' സ്ഥാനത്തേക്ക് തിരിക്കുക.
  3. Move the engine switch to the 'CHOKE' position (if the engine is cold).
  4. എഞ്ചിൻ ആരംഭിക്കുന്നത് വരെ റീകോയിൽ സ്റ്റാർട്ടർ ഹാൻഡിൽ ശക്തമായി വലിക്കുക.
  5. Once the engine starts, gradually move the engine switch to the 'RUN' position.
  6. വൈദ്യുതി ലോഡുകൾ ബന്ധിപ്പിക്കുന്നതിന് മുമ്പ് ജനറേറ്റർ കുറച്ച് മിനിറ്റ് ചൂടാക്കാൻ അനുവദിക്കുക.
Pulsar GD240N generator with engine switch set to RUN

Image: The side of the Pulsar GD240N generator showing the engine switch in the 'RUN' position.

ഇക്കോ മോഡ്

The Eco Mode switch allows the generator to adjust engine speed based on the load, optimizing fuel consumption and reducing noise levels. For light loads, switch to 'ON' for quieter and more efficient operation. For heavy loads or when starting high-demand appliances, switch to 'OFF' to ensure full power is available.

ഉപകരണങ്ങൾ ബന്ധിപ്പിക്കുന്നു

Connect your electrical devices to the appropriate outlets on the control panel. Ensure that the total wattagകണക്റ്റുചെയ്‌ത ഉപകരണങ്ങളുടെ എണ്ണം ജനറേറ്ററിന്റെ റണ്ണിംഗ് വാട്ടിനെ കവിയരുത്.tage (1800W) to prevent overloading.

സമാന്തര പ്രവർത്തനം

The Pulsar GD240N is equipped with parallel connection ports, allowing you to link two compatible Pulsar inverter generators together to double your power output. Refer to the parallel kit's instruction manual for detailed connection procedures.

മെയിൻ്റനൻസ്

Regular maintenance is crucial for the optimal performance and longevity of your generator. Always ensure the engine is off and cool before performing any maintenance.

എഞ്ചിൻ ഓയിൽ മാറ്റം

Change the engine oil after the first 20 hours of use or the first month, whichever comes first. Subsequent oil changes should be performed every 100 hours or every 6 months.

  1. ഓയിൽ ഡ്രെയിൻ പ്ലഗിന് കീഴിൽ അനുയോജ്യമായ ഒരു പാത്രം വയ്ക്കുക.
  2. Remove the oil drain plug and the oil fill cap to allow the oil to drain completely.
  3. Once drained, replace the oil drain plug.
  4. Refill with fresh 5W-30 engine oil as described in the 'Adding Engine Oil' section.

Spark Plug Access

The spark plug is accessible for inspection and replacement. Remove the spark plug cover to access the spark plug. Inspect the spark plug for wear and proper gap. Replace if necessary.

സ്പാർക്ക് അറെസ്റ്റർ

The generator is equipped with a spark arrestor, making it US Forestry approved. Regularly inspect and clean the spark arrestor to prevent carbon buildup, which can restrict exhaust flow and affect performance. Refer to the owner's manual for detailed cleaning instructions.

Pulsar GD240N generator exhaust and spark arrestor

ചിത്രം: പിൻഭാഗം view of the Pulsar GD240N generator, highlighting the exhaust port and spark arrestor.

ട്രബിൾഷൂട്ടിംഗ്

If your generator experiences issues, consult the following common troubleshooting tips:

ഇൻഡിക്കേറ്റർ ലൈറ്റുകൾ

പൊതുവായ പ്രശ്നങ്ങൾ

സ്പെസിഫിക്കേഷനുകൾ

ബ്രാൻഡ്പൾസർ
മോഡലിൻ്റെ പേര്Pulsar 2,400W Portable Gas-Powered Quiet Inverter Generator With USB Outlet & Parallel Capability, GD240N
ഭാഗം നമ്പർGD240N
വാട്ട് ആരംഭിക്കുന്നുtage2400 വാട്ട്സ്
റണ്ണിംഗ് വാട്ട്tage1800 വാട്ട്സ്
ഇന്ധന തരംഗ്യാസോലിൻ
പവർ ഉറവിടംഇന്ധനം ഉപയോഗിച്ച് പ്രവർത്തിക്കുന്ന
വാല്യംtage120 വോൾട്ട്
എഞ്ചിൻ തരം4 സ്ട്രോക്ക്
ടാങ്ക് വോളിയം1.18 ഗാലൻ
ഇനത്തിൻ്റെ ഭാരം30.8 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ17.3"L x 9.7"W x 15.9"H
മൊത്തം പവർ ഔട്ട്ലെറ്റുകൾ2 (AC 120V 20A) + 1 (AC 120V 30A) + USB Type A + USB Type C + DC 12V
പ്രത്യേക സവിശേഷതകൾExtra-Long Run Time, Fuel Efficient, Lightweight, Low Oil Shutdown, Portable

വാറൻ്റിയും പിന്തുണയും

വാറൻ്റി വിവരങ്ങൾ

This Pulsar GD240N inverter generator comes with a 2-Year Manufacturer's Warranty. Please retain your proof of purchase for warranty claims.

ഉപഭോക്തൃ പിന്തുണ

For technical assistance, warranty inquiries, or to order replacement parts, please contact Pulsar Products customer support. Refer to the official Pulsar webബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങൾക്ക് സൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ വാങ്ങൽ ഡോക്യുമെന്റേഷൻ.

അനുബന്ധ രേഖകൾ - GD240N

പ്രീview പൾസർ PG2200BiS ഇൻവെർട്ടർ ഗ്യാസോലിൻ ജനറേറ്റർ ഓപ്പറേറ്ററുടെ മാനുവൽ
പൾസർ PG2200BiS പോർട്ടബിൾ ഇൻവെർട്ടർ ഗ്യാസോലിൻ ജനറേറ്ററിനായുള്ള സമഗ്രമായ ഓപ്പറേറ്റർ മാനുവൽ, വിശ്വസനീയമായ പ്രകടനം ഉറപ്പാക്കുന്നതിന് സുരക്ഷ, പ്രവർത്തനം, അറ്റകുറ്റപ്പണികൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview പൾസർ PG2000iS/PG2300iS പോർട്ടബിൾ ഇൻവെർട്ടർ ജനറേറ്റർ ഓപ്പറേറ്ററുടെ മാനുവൽ
പൾസർ PG2000iS, PG2300iS പോർട്ടബിൾ ഇൻവെർട്ടർ ഗ്യാസോലിൻ ജനറേറ്ററുകളുടെ സുരക്ഷിതമായ പ്രവർത്തനം, അസംബ്ലി, അറ്റകുറ്റപ്പണി, ട്രബിൾഷൂട്ടിംഗ് എന്നിവയ്ക്കുള്ള അവശ്യ വിവരങ്ങൾ ഈ ഓപ്പറേറ്ററുടെ മാനുവൽ നൽകുന്നു. നിങ്ങളുടെ ജനറേറ്റർ എങ്ങനെ ഫലപ്രദമായും സുരക്ഷിതമായും ഉപയോഗിക്കാമെന്ന് മനസിലാക്കുക.
പ്രീview Pulsar 1600 Watt Inverter Generator Operator's Manual PGD16iSCO
Comprehensive operator's manual for the Pulsar PGD16iSCO 1600 Watt Inverter Generator. Includes detailed safety instructions, operating procedures, maintenance schedules, troubleshooting guides, and technical specifications for safe and efficient use.
പ്രീview പൾസർ PG2300iSCO ഇൻവെർട്ടർ ഗ്യാസോലിൻ ജനറേറ്റർ ഓപ്പറേറ്ററുടെ മാനുവൽ
പൾസർ PG2300iSCO ഇൻവെർട്ടർ ഗ്യാസോലിൻ ജനറേറ്ററിനായുള്ള സമഗ്ര ഓപ്പറേറ്ററുടെ മാനുവൽ. സുരക്ഷാ നിയമങ്ങൾ, ഉൽപ്പന്ന സവിശേഷതകൾ, അസംബ്ലി നിർദ്ദേശങ്ങൾ, വിശദമായ പ്രവർത്തന നടപടിക്രമങ്ങൾ, അറ്റകുറ്റപ്പണി ഷെഡ്യൂളുകൾ, ട്രബിൾഷൂട്ടിംഗ് നുറുങ്ങുകൾ, ജനറേറ്ററിന്റെ സുരക്ഷിതവും ഫലപ്രദവുമായ ഉപയോഗത്തിനുള്ള വയറിംഗ് ഡയഗ്രം എന്നിവയുൾപ്പെടെയുള്ള അവശ്യ വിവരങ്ങൾ ഈ ഗൈഡിൽ ഉൾക്കൊള്ളുന്നു.
പ്രീview പൾസർ PG4500BiSRCO ഇൻവെർട്ടർ ജനറേറ്റർ ഓപ്പറേറ്ററുടെ മാനുവൽ
പൾസർ PG4500BiSRCO ഇൻവെർട്ടർ ജനറേറ്ററിനായുള്ള ഓപ്പറേറ്ററുടെ മാനുവൽ, ഗ്യാസോലിൻ, LPG ഡ്യുവൽ-ഫ്യുവൽ ഉപയോഗത്തിനുള്ള സുരക്ഷ, സവിശേഷതകൾ, പ്രവർത്തനം, പരിപാലനം, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview പൾസർ PG4500iSR ഇൻവെർട്ടർ ജനറേറ്റർ ഓപ്പറേറ്ററുടെ മാനുവൽ
പൾസർ PG4500iSR ഗ്യാസോലിൻ ഇൻവെർട്ടർ ജനറേറ്ററിനായുള്ള സമഗ്രമായ ഓപ്പറേറ്റർ മാനുവൽ, സുരക്ഷ, സവിശേഷതകൾ, പ്രവർത്തനം, പരിപാലനം, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.