Hochiki RPV-AAW20

Hochiki Type P1 Fire Alarm Panel RPV-AAW20 User Manual

മോഡൽ: RPV-AAW20 | ബ്രാൻഡ്: Hochiki Corporation

Approval No.: 28-3

1. ആമുഖം

This manual provides comprehensive instructions for the safe and effective use of the Hochiki Type P1 Fire Alarm Panel, model RPV-AAW20. This device is a 20-line wall-mounted fire alarm control panel designed for reliable fire detection and alarm management. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functionality and safety.

2 സുരക്ഷാ വിവരങ്ങൾ

പ്രധാനപ്പെട്ട സുരക്ഷാ നിർദ്ദേശങ്ങൾ:

  • Installation and servicing must be performed by qualified personnel only, in accordance with all local and national electrical and fire safety codes.
  • Disconnect all power sources before performing any maintenance or service on the panel.
  • Do not operate the panel with damaged components or wiring.
  • Ensure the panel is securely mounted to a wall in a suitable environment, away from excessive moisture, dust, or extreme temperatures.
  • Regularly test the system as recommended by local regulations and this manual to ensure proper operation.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Hochiki RPV-AAW20 is a Type P1 fire alarm control panel capable of monitoring up to 20 fire detection zones. It features a clear display for status indication, integrated controls for alarm management, and a communication function.

Hochiki Type P1 Fire Alarm Panel RPV-AAW20

ചിത്രം 1: ഫ്രണ്ട് view of the Hochiki Type P1 Fire Alarm Panel RPV-AAW20. The panel features a main display area for fire alarm status, individual zone indicators, a microphone for communication, and buttons for sound stop and fault confirmation.

പ്രധാന ഘടകങ്ങൾ:

  • Fire Alarm Control Panel (火災受信盤): Main display and indicator section.
  • Fire Indicator (火災): Illuminates when a fire alarm is detected.
  • Microphone (マイク): Used for communication functions.
  • Listen to Information (状況に応じた情報を聞く): Button to access status information or voice guidance.
  • Determine/Confirm (断定): Button for confirming events or system status.
  • Sound Stop (音響停止): Button to silence the local panel's alarm sound.
  • Area (Bell) Temporary Stop (地区(ベル)一時停止): Button to temporarily silence building bells/sirens in a specific area.

4. സജ്ജീകരണം

The RPV-AAW20 fire alarm panel requires professional installation. This section provides a general overview; refer to the detailed installation manual provided with the product for specific wiring diagrams and procedures.

4.1 മൗണ്ടിംഗ്

  • Select a suitable wall location that is easily accessible, visible, and protected from environmental hazards.
  • Ensure the mounting surface can support the weight of the panel.
  • Securely mount the panel using appropriate fasteners.

4.2 വയറിംഗ്

  • Connect the main power supply according to local electrical codes.
  • Connect fire detection zones (detectors, manual call points) to the designated terminals.
  • Connect alarm notification appliances (bells, strobes) and auxiliary devices.
  • Ensure all wiring is correctly terminated and secured.

4.3 പ്രാരംഭ പവർ-അപ്പും പരിശോധനയും

  • After all connections are made, apply power to the panel.
  • Observe the panel for initial self-tests and status indicators.
  • Perform a comprehensive system test to verify proper operation of all detectors, notification appliances, and control functions.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1 സാധാരണ പ്രവർത്തനം

In normal operation, the panel's status indicators should show no alarms or faults. The power indicator should be illuminated.

5.2 When a Fire Alarm Sounds (火災警報音が困ったとき)

  1. Identify the Alarm: The 'Fire' indicator will illuminate, and the panel will sound an alarm. Check the zone indicators to identify the location of the alarm.
  2. Assess the Situation: Visually inspect the indicated area if safe to do so.
  3. Silence Local Panel Sound: അമർത്തുക Sound Stop (音響停止) button to silence the local panel's alarm sound. The 'Fire' indicator will remain illuminated until the alarm condition is cleared.
  4. Silence Building Bells (Temporarily): ആവശ്യമെങ്കിൽ, അമർത്തുക Area (Bell) Temporary Stop (地区(ベル)一時停止) button to temporarily silence the building's bells/sirens in the affected area.
  5. Contact Emergency Services: Immediately contact local fire emergency services (e.g., 119 in Japan) and provide them with the alarm location and any relevant information.
  6. ഒഴിപ്പിക്കുക: Follow established evacuation procedures.

5.3 Using the Communication Function (電話ですと思ったとき)

The panel is equipped with a microphone for communication purposes, potentially for intercom or emergency communication with specific points in the building.

  • To initiate communication, activate the relevant function (refer to the detailed operational guide for specific steps).
  • Speak clearly into the Microphone (マイク).

5.4 Listening to Information (状況に応じた情報を聞く)

അമർത്തുക Listen to Information (状況に応じた情報を聞く) button to receive status updates or voice guidance from the panel regarding its current state or an event.

6. പരിപാലനം

Regular maintenance is crucial for the reliable operation of your fire alarm system. It should be performed by qualified technicians.

6.1 പ്രതിദിന പരിശോധനകൾ

  • Verify that the 'Power' indicator is illuminated.
  • Check for any fault indicators or unusual sounds.

6.2 ആനുകാലിക പരിശോധന

  • Conduct regular tests of detectors, manual call points, and alarm notification appliances as per local regulations (e.g., monthly, quarterly, annually).
  • Test the panel's battery backup system to ensure it functions during power outages.

6.3 വൃത്തിയാക്കൽ

  • Gently wipe the exterior of the panel with a soft, dry cloth.
  • ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.

7. പ്രശ്‌നപരിഹാരം

This section addresses common issues you might encounter with the RPV-AAW20 panel. For complex problems, always contact a qualified service technician.

7.1 When a Fault Sound Occurs (障害音質が困ったとき)

If the panel emits a fault sound or displays a fault indicator:

  • Check Error Codes: Look for any displayed error codes on the panel. Refer to the detailed product manual for a list of error codes and their meanings.
  • Identify the Fault: The panel will typically indicate the type of fault (e.g., power failure, zone fault, communication error).
  • ബന്ധപ്പെടാനുള്ള സേവനം: For most fault conditions, especially those involving internal components or wiring, contact a qualified Hochiki service technician. Do not attempt repairs yourself unless specifically instructed and qualified.
  • മെയിന്റനൻസ് സ്വിച്ച്: If instructed by a technician, you may need to access the maintenance switch by removing its cover. This should only be done under professional guidance.

7.2 Panel Not Powering On

  • Check the main power supply to the panel.
  • Verify that the circuit breaker for the panel is not tripped.
  • Ensure internal battery connections are secure (if applicable).

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
മോഡൽRPV-AAW20
ടൈപ്പ് ചെയ്യുകP1 Fire Alarm Panel
വരികളുടെ എണ്ണം20
മൗണ്ടിംഗ്മതിൽ ഘടിപ്പിച്ചത്
നിർമ്മാതാവ്Hochiki Corporation
അംഗീകാര നമ്പർ28-3
ആദ്യം ലഭ്യമായ തീയതി2024/06/10

9. വാറൻ്റിയും പിന്തുണയും

For warranty information, technical support, or service requests, please contact your authorized Hochiki dealer or the Hochiki Corporation directly. Keep your purchase receipt and model number (RPV-AAW20) readily available when contacting support.

അനുബന്ധ രേഖകൾ - RPV-AAW20

പ്രീview FNV 25 / FNV 50 / FNV 100 Voice Evacuation Interface System Installation Instructions
Comprehensive installation guide for the Hochiki FNV 25, FNV 50, and FNV 100 Voice Evacuation Interface Systems. Covers system overview, installation procedures, wiring details, terminal designations, operation, specifications, switch settings, and troubleshooting.
പ്രീview ഹോച്ചിക്കി ഫയർനെറ്റ് ഗ്രാഫിക്സ്: ഇൻസ്റ്റാളേഷനും പ്രോഗ്രാമിംഗ് മാനുവലും
ഹോച്ചിക്കി ഫയർനെറ്റ് ഗ്രാഫിക്സ് ഫയർ അലാറം സിസ്റ്റം ഗ്രാഫിക്സ് സോഫ്റ്റ്‌വെയർ ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനും കോൺഫിഗർ ചെയ്യുന്നതിനും പ്രോഗ്രാമിംഗ് ചെയ്യുന്നതിനുമുള്ള ഒരു സമഗ്ര ഗൈഡ്. സിസ്റ്റത്തെ മുഴുവൻ ഉൾക്കൊള്ളുന്നു.view, ഹാർഡ്‌വെയർ ഇൻസ്റ്റാളേഷൻ, സോഫ്റ്റ്‌വെയർ സജ്ജീകരണം, ആപ്ലിക്കേഷൻ പ്രവർത്തിപ്പിക്കൽ, ഡിസൈൻ ടൂളുകൾ, യൂട്ടിലിറ്റികൾ.
പ്രീview FN-1127 കൺട്രോൾ പാനലിനും FN-LCD-S അനൗൺസിയേറ്ററുകൾക്കുമുള്ള ഹോച്ചിക്കി ഫയർനെറ്റ് പ്ലസ് പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Comprehensive operating instructions for the Hochiki FireNET PLUS FN-1127 control panel and FN-LCD-S annunciators, detailing fire and trouble conditions, button functions, fuse replacement, battery maintenance, and SOM-R releasing ഫംഗ്‌ഷൻ.
പ്രീview Dating Hochiki Fire Alarm Devices: A Guide by Fire Trade Supplies
Learn how to date Hochiki fire alarm devices, including the ATJ-EN model, using serial numbers and manufacturing codes. Find contact details for Fire Trade Supplies.
പ്രീview ഹോച്ചിക്കി ഉൽപ്പന്ന ഗൈഡ് ISS30:MAR24 - അഗ്നി കണ്ടെത്തൽ സംവിധാനങ്ങളും പരിഹാരങ്ങളും
ഹോച്ചിക്കിയിൽ നിന്നുള്ള സമഗ്രമായ ഉൽപ്പന്ന ഗൈഡ്, അഡ്രസ് ചെയ്യാവുന്ന, പരമ്പരാഗത, വയർലെസ്, എയർ എന്നിവയുൾപ്പെടെയുള്ള അവരുടെ വിപുലമായ അഗ്നിശമന സംവിധാനങ്ങൾ വിശദീകരിക്കുന്നു.ampലിംഗ് സാങ്കേതികവിദ്യകൾ. അഗ്നി സുരക്ഷാ നവീകരണത്തോടുള്ള ഹോച്ചിക്കിയുടെ പ്രതിബദ്ധതയെക്കുറിച്ച് അറിയുക.
പ്രീview ഹോച്ചിക്കി HFP AP സിംഗിൾ/ടു ലൂപ്പ് കൺട്രോൾ പാനൽ റേഞ്ച് ഉൽപ്പന്ന മാനുവൽ
ഹോച്ചിക്കി എച്ച്എഫ്‌പി എപി സിംഗിൾ/ടു ലൂപ്പ് കൺട്രോൾ പാനൽ ശ്രേണിക്കായുള്ള സമഗ്രമായ ഉൽപ്പന്ന മാനുവൽ, ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, പ്രോഗ്രാമിംഗ് എന്നിവ വിശദമാക്കുന്നു. സാങ്കേതിക സവിശേഷതകൾ, സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ, കേബിളിംഗ്, ഫ്രണ്ട് പാനൽ നിയന്ത്രണങ്ങൾ, കോൺഫിഗറേഷൻ ഓപ്ഷനുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.