Rexroth 4WE6J6X-EG24N9K4

Rexroth Hydraulic Electromagnetic Directional Valve 4WE6J6X-EG24N9K4 User Manual

1. ആമുഖം

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Rexroth Hydraulic Electromagnetic Directional Valve, model 4WE6J6X-EG24N9K4. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2 സുരക്ഷാ വിവരങ്ങൾ

Working with hydraulic systems requires strict adherence to safety protocols. Failure to follow these instructions can result in serious injury, death, or property damage.

  • യോഗ്യതയുള്ള ഉദ്യോഗസ്ഥർ: Installation, maintenance, and repair must only be performed by trained and qualified personnel familiar with hydraulic systems and electrical components.
  • Pressure Hazard: Hydraulic systems operate under high pressure. Always depressurize the system completely before performing any work on the valve or associated components.
  • വൈദ്യുത അപകടം: The electromagnetic coil operates with electrical power. Disconnect all power to the valve before installation, maintenance, or troubleshooting.
  • Fluid Hazard: Hydraulic fluid can be hot and under pressure. Wear appropriate personal protective equipment (PPE), including eye protection and gloves, to prevent skin contact and burns.
  • സിസ്റ്റം അനുയോജ്യത: Ensure the valve is compatible with the hydraulic fluid, pressure, and flow rates of your system.
  • പാരിസ്ഥിതിക പരിഗണനകൾ: Dispose of hydraulic fluid and components according to local environmental regulations.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Rexroth 4WE6J6X-EG24N9K4 is a high-performance hydraulic electromagnetic directional valve designed for controlling the direction of fluid flow in hydraulic systems. It features a robust construction suitable for industrial applications, ensuring reliable operation and precise control.

Rexroth 4WE6J6X-EG24N9K4 hydraulic electromagnetic directional valve

ചിത്രം 1: Rexroth Hydraulic Electromagnetic Directional Valve, Model 4WE6J6X-EG24N9K4. This image displays the Rexroth hydraulic electromagnetic directional valve, model 4WE6J6X-EG24N9K4. The valve features a blue central body with the 'Rexroth' logo and model number '4WE 6 J62/EG24N9K4' clearly visible. It also indicates a maximum pressure of 350 bar. Transparent plastic covers are visible on both ends, protecting the electrical connections.

4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Proper installation is crucial for the valve's performance and longevity. Always refer to the system's hydraulic schematic and electrical diagrams.

  1. തയ്യാറാക്കൽ: Ensure the hydraulic system is depressurized and all electrical power is disconnected. Clean the mounting surface and valve ports to prevent contamination.
  2. മൗണ്ടിംഗ്: Mount the valve securely to the manifold or subplate using appropriate bolts and torque specifications. Ensure O-rings or gaskets are correctly seated to prevent leaks.
  3. ഹൈഡ്രോളിക് കണക്ഷനുകൾ: Connect the hydraulic lines to the designated ports (P, A, B, T) according to the system's schematic. Double-check all connections for tightness.
  4. ഇലക്ട്രിക്കൽ കണക്ഷനുകൾ: Connect the electrical wiring to the solenoid coil(s) as per the electrical diagram. Ensure correct voltage (24V DC for EG24N9K4) and polarity. Secure all electrical connections and protect them from moisture.
  5. സിസ്റ്റം ആരംഭം: Slowly re-pressurize the hydraulic system and check for leaks. Restore electrical power and test the valve's operation. Bleed air from the system if necessary.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The 4WE6J6X-EG24N9K4 valve is an electromagnetically actuated directional control valve. Its operation is controlled by applying electrical power to the solenoid coil(s).

  • Solenoid Activation: When the solenoid coil is energized, it shifts the valve spool, directing hydraulic fluid flow to the desired port (e.g., from P to A and B to T, or P to B and A to T).
  • ഊർജ്ജസ്വലത കുറഞ്ഞ അവസ്ഥ: When the solenoid is de-energized, the spool returns to its neutral or spring-centered position, typically blocking all ports or allowing a specific flow path depending on the valve configuration.
  • നിരീക്ഷണം: Continuously monitor system pressure, temperature, and fluid levels during operation.

6. പരിപാലനം

Regular maintenance ensures optimal performance and extends the lifespan of the valve.

  • ദ്രാവക ഗുണനിലവാരം: Maintain clean hydraulic fluid. Contamination is a leading cause of valve failure. Regularly check and replace filters.
  • ചോർച്ച പരിശോധന: Periodically inspect the valve and connections for any signs of hydraulic fluid leaks. Address leaks immediately.
  • ഇലക്ട്രിക്കൽ കണക്ഷനുകൾ: Check electrical connections for corrosion or looseness. Ensure wiring is intact and properly insulated.
  • മൗണ്ടിംഗ് സെക്യൂരിറ്റി: Verify that the valve remains securely mounted.
  • ഘടകം മാറ്റിസ്ഥാപിക്കൽ: If any part of the valve, such as the solenoid coil or seals, shows signs of wear or damage, replace it with genuine Rexroth spare parts.

7. പ്രശ്‌നപരിഹാരം

Before troubleshooting, ensure all safety precautions are observed.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
Valve does not shiftNo electrical power to solenoid
Solenoid coil faulty
Spool jammed by contamination
വയറിംഗും വൈദ്യുതി വിതരണവും പരിശോധിക്കുക
Test and replace solenoid coil
Depressurize system, inspect and clean valve spool
Valve leaks externallyഅയഞ്ഞ കണക്ഷനുകൾ
കേടായ O-റിംഗുകൾ/സീലുകൾ
Tighten hydraulic connections
Replace O-rings/seals
തെറ്റായ ഒഴുക്ക് ദിശതെറ്റായ വയറിംഗ്
Valve spool malfunction
Verify electrical connections against schematic
Inspect valve spool for damage or obstruction
Reduced flow or pressureContaminated fluid/filters
Partial spool blockage
Check and replace hydraulic filters
Inspect and clean valve spool

8 സ്പെസിഫിക്കേഷനുകൾ

സ്പെസിഫിക്കേഷൻവിശദാംശങ്ങൾ
ഉൽപ്പന്ന തരംHydraulic Electromagnetic Directional Valve
ബ്രാൻഡ്റെക്സ്റോത്ത്
മോഡൽ നമ്പർ4WE6J6X-EG24N9K4
പരമാവധി പ്രവർത്തന സമ്മർദ്ദം350 bar (as indicated on product)
ഇലക്ട്രിക്കൽ വോളിയംtage24V DC (EG24N9K4 designation)
ഇനത്തിൻ്റെ ഭാരംഏകദേശം 1 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ (L x W x H)ഏകദേശം 1 x 1 x 1 ഇഞ്ച്
നിർമ്മാതാവ്Original factory (Rexroth)
ആദ്യ തീയതി ലഭ്യമാണ്ഓഗസ്റ്റ് 21, 2024

9. വാറൻ്റിയും പിന്തുണയും

For specific warranty terms, technical support, or replacement parts, please contact your original point of purchase or the authorized Rexroth distributor. Keep your purchase receipt and product model number readily available when seeking support.

അനുബന്ധ രേഖകൾ - 4WE6J6X-EG24N9K4

പ്രീview ബോഷ് റെക്‌സ്‌റോത്ത് ഗോടോ പ്രോഗ്രാം: വടക്കേ അമേരിക്കയ്ക്കുള്ള ഇലക്ട്രിക് ഡ്രൈവുകളും നിയന്ത്രണങ്ങളും കാറ്റലോഗ്
ബോഷ് റെക്‌സ്‌റോത്ത് ഗോടോ ഫോക്കസ്ഡ് ഡെലിവറി പ്രോഗ്രാം ഫോർ ഇലക്ട്രിക് ഡ്രൈവുകളും കൺട്രോളുകളും പര്യവേക്ഷണം ചെയ്യുക. ഉയർന്ന ഡിമാൻഡുള്ള ഉൽപ്പന്നങ്ങളിലേക്ക് ഈ പ്രോഗ്രാം എങ്ങനെ വേഗത്തിൽ പ്രവേശനം നൽകുന്നുവെന്നും, വേഗത്തിലുള്ള ലീഡ് സമയങ്ങളും വ്യാവസായിക ഓട്ടോമേഷൻ ആപ്ലിക്കേഷനുകൾക്ക് ഉയർന്ന ലഭ്യതയും ഉറപ്പാക്കുന്നതെങ്ങനെയെന്നും കണ്ടെത്തുക.
പ്രീview Rexroth EFC 3610 / EFC 5610 Series Frequency Converter Operating Instructions
Operating instructions for the Rexroth EFC 3610 and EFC 5610 series frequency converters. This document provides essential safety information and operational guidance for these industrial drive components.
പ്രീview റെക്‌സ്‌റോത്ത് ഇന്ദ്രഡ്രൈവ് ഇന്റഗ്രേറ്റഡ് സേഫ്റ്റി ടെക്‌നോളജി ഫങ്ഷണൽ വിവരണം
IEC 61508 മാനദണ്ഡങ്ങൾക്കനുസൃതമായി രൂപകൽപ്പന ചെയ്‌തിരിക്കുന്ന റെക്‌സ്‌റോത്ത് ഇന്ദ്രഡ്രൈവ് സിസ്റ്റത്തിന്റെ സംയോജിത സുരക്ഷാ സാങ്കേതികവിദ്യ പര്യവേക്ഷണം ചെയ്യുക. ഈ പ്രവർത്തന വിവരണം അതിന്റെ സവിശേഷതകൾ, പ്രവർത്തനങ്ങൾ, വ്യാവസായിക ഓട്ടോമേഷനിലെ പ്രയോഗങ്ങൾ എന്നിവ വിശദമായി പ്രതിപാദിക്കുന്നു.
പ്രീview Rexroth IndraDrive MPx02 MPx05 HMV Error Messages and Warnings Troubleshooting Guide
This troubleshooting guide from Bosch Rexroth details error messages and warnings for IndraDrive MPx02, MPx05, and HMV drive controllers, assisting operators and programmers in diagnosing and resolving system issues.
പ്രീview Rexroth Industrial Hydraulics Project Manual: Single-Rod Cylinder and Pressure Intensification
A comprehensive trainee's project manual on industrial hydraulics by Rexroth, focusing on single-rod cylinders and pressure intensification. Covers project definition, tasks, circuit diagrams, safety, execution, and evaluation for practical learning.
പ്രീview Rexroth IndraDrive Integrated Safety Technology: Functional and Application Description
This document provides a comprehensive functional and application description for the Rexroth IndraDrive system with integrated safety technology, covering its features, safety functions, commissioning, and troubleshooting.