ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System User Manual

Model: B0DHFF2DKL

1. ആമുഖം

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2 സുരക്ഷാ വിവരങ്ങൾ

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • ഇലക്ട്രിക്കൽ സുരക്ഷ: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • റഫ്രിജറന്റ് കൈകാര്യം ചെയ്യൽ: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • ഇൻസ്റ്റലേഷൻ: Installation must be performed by a licensed HVAC professional.
  • വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3 പ്രധാന സവിശേഷതകൾ

  • ഇൻവെർട്ടർ സാങ്കേതികവിദ്യ: കൃത്യമായ താപനില നിയന്ത്രണം, കുറഞ്ഞ ഊർജ്ജ ഉപഭോഗം, ശാന്തമായ പ്രവർത്തനം എന്നിവ നൽകുന്നു.
  • ഉയർന്ന കാര്യക്ഷമത: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • വിശാലമായ പ്രവർത്തന ശ്രേണി: Reliable performance from -13°F to 122°F.
  • ശാന്തമായ പ്രവർത്തനം: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • നീണ്ടുനിൽക്കുന്ന ഘടകങ്ങൾ: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • പരിസ്ഥിതി സൗഹൃദ റഫ്രിജറൻ്റ്: Utilizes R-454B refrigerant.
  • ഫ്ലെക്സിബിൾ ഇൻസ്റ്റലേഷൻ: Supports horizontal and vertical air handler installation.
  • സ്മാർട്ട് നിയന്ത്രണങ്ങൾ: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. ഘടകങ്ങൾ കഴിഞ്ഞുview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • വൈഫൈ തെർമോസ്റ്റാറ്റ്
  • സർജ് പ്രൊട്ടക്ടർ
  • CPS Charging Adapter
  • വാൾ സ്ലീവ്
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

ചിത്രം 1: കഴിഞ്ഞുview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധനകൾ

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • ശരിയായ വായുസഞ്ചാരവും അറ്റകുറ്റപ്പണികളും ഉറപ്പാക്കിക്കൊണ്ട് ഇൻഡോർ, ഔട്ട്ഡോർ യൂണിറ്റുകൾക്ക് മതിയായ ഇടം ഉറപ്പാക്കുക.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

ചിത്രം 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Outdoor Unit Placement

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

ചിത്രം 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 അടിസ്ഥാന പ്രവർത്തന രീതികൾ

  • കൂളിംഗ് മോഡ്: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • ചൂടാക്കൽ മോഡ്: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • ഫാൻ മോഡ്: ചൂടാക്കുകയോ തണുപ്പിക്കുകയോ ചെയ്യാതെ വായു സഞ്ചാരം നടത്തുന്നു.
  • യാന്ത്രിക മോഡ്: നിശ്ചിത താപനില നിലനിർത്താൻ ചൂടാക്കലിനും തണുപ്പിക്കലിനും ഇടയിൽ യാന്ത്രികമായി മാറുന്നു.
ACiQ outdoor unit operating in extreme heat

ചിത്രം 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

ചിത്രം 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

ചിത്രം 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. പരിപാലനം

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • എയർ ഫിൽറ്റർ മാറ്റിസ്ഥാപിക്കൽ: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • ഔട്ട്ഡോർ യൂണിറ്റ് വൃത്തിയാക്കൽ: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • ജലനിര്ഗ്ഗമനസംവിധാനം: വെള്ളം കവിഞ്ഞൊഴുകുന്നത് തടയാൻ കണ്ടൻസേറ്റ് ഡ്രെയിനേജ് ലൈൻ വ്യക്തമാണെന്നും തടസ്സങ്ങളില്ലെന്നും ഉറപ്പാക്കുക.
  • പ്രൊഫഷണൽ പരിശോധന: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. പ്രശ്‌നപരിഹാരം

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • ശക്തിയില്ല: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • അസാധാരണമായ ശബ്ദങ്ങൾ: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • വെള്ളം ചോർച്ച: Check condensate drain line for blockages.

9 സ്പെസിഫിക്കേഷനുകൾ

Dimensions of ACiQ indoor and outdoor units

ചിത്രം 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

ചിത്രം 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

ചിത്രം 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

ഫീച്ചർവിശദാംശങ്ങൾ
തണുപ്പിക്കൽ ശേഷി31,000 BTU/hr
ചൂടാക്കൽ ശേഷി30,000 BTU/hr (at 47°F)
SEER2 റേറ്റിംഗ്18.8
HSPF2 റേറ്റിംഗ്9.7
ശീതീകരണ തരംR-454B
ഇൻഡോർ യൂണിറ്റ് പവർ സപ്ലൈ115/208/230V, 60Hz, 1Ph
Outdoor Unit Power Supply208/230V, 60Hz, 1Ph
പരമാവധി പൈപ്പിംഗ് ദൈർഘ്യം164 അടി (50 മീറ്റർ)
Max Height Difference82 അടി (25 മീറ്റർ)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
ഇൻഡോർ യൂണിറ്റിന്റെ മൊത്തം ഭാരം128.97 പൗണ്ട്
ഔട്ട്ഡോർ യൂണിറ്റിന്റെ മൊത്തം ഭാരം164.02 പൗണ്ട്

10. വാറൻ്റിയും പിന്തുണയും

ACiQ offers a comprehensive warranty for this heat pump system:

  • ഭാഗങ്ങളുടെ വാറൻ്റി: 7 വർഷം
  • കംപ്രസർ വാറൻ്റി: 12 വർഷം

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webസൈറ്റ്.

അനുബന്ധ രേഖകൾ - B0DHFF2DKL

പ്രീview ACiQ 9K-24K Standard Heat Single-Zone Systems: Installation & Owner's Manual
ACiQ 9K-24K Standard Heat Single-Zone Systems Installation & Owner's Manual. This guide details installation, operation, safety, and maintenance for ACiQ air conditioners, including model specifics and R454B refrigerant information.
പ്രീview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
പ്രീview ACiQ Wall-Mounted Air Handler & Extreme Heat Single-Zone Condenser Installation & Owner's Manual
This manual provides detailed installation, operation, and safety guidelines for ACiQ wall-mounted air handlers and extreme heat single-zone condensers, covering models ACIQ-06W-HH-MD through ACIQ-24ZPL-HP230C.
പ്രീview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
പ്രീview ACiQ Next Gen Ducted Heat Pump System: Quick Start Guide for Thermostat Wiring
This guide provides essential information for connecting and wiring thermostats to the ACiQ Next Gen Ducted Heat Pump System. It details recommended and alternative connection options, including DIP switch settings and terminal block configurations for various thermostat types.
പ്രീview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.