1. ആമുഖം
Thank you for choosing the MAXSafes Model 10002V Drop Down Biometric Handgun Safe. This safe is designed to provide secure storage and quick access to your firearm using advanced finger vein recognition, a digital keypad, or a mechanical key. Please read this manual thoroughly before installation and operation to ensure proper use and maximum security.

Figure 1: MAXSafes Model 10002V Drop Down Biometric Handgun Safe
2 സുരക്ഷാ വിവരങ്ങൾ
മുന്നറിയിപ്പ്: Always store firearms unloaded and separate from ammunition. Keep the safe locked and out of reach of children and unauthorized individuals. Never store the mechanical override keys inside the safe. Familiarize yourself with all local and federal laws regarding firearm storage.
- അനധികൃതമായി നീക്കം ചെയ്യുന്നത് തടയാൻ സേഫ് സുരക്ഷിതമായി ഘടിപ്പിച്ചിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക.
- Do not leave the safe open or unattended.
- Test all access methods periodically to ensure proper function.
- കുറഞ്ഞ ബാറ്ററി സൂചകം പ്രത്യക്ഷപ്പെടുമ്പോൾ ബാറ്ററികൾ ഉടൻ മാറ്റിസ്ഥാപിക്കുക.
3. പാക്കേജ് ഉള്ളടക്കം
പാക്കേജിൽ എല്ലാ ഇനങ്ങളും ഉണ്ടെന്ന് ഉറപ്പാക്കുക:
- MAXSafes Model 10002V Handgun Safe
- Mechanical Override Keys (2)
- മൗണ്ടിംഗ് ഹാർഡ്വെയർ (സ്ക്രൂകൾ, ആങ്കറുകൾ)
- നിർദ്ദേശ മാനുവൽ (ഈ പ്രമാണം)
4. ഉൽപ്പന്നം കഴിഞ്ഞുview
The MAXSafes 10002V features a robust design with multiple access options for enhanced security and convenience.

Figure 2: Key Features of the MAXSafes 10002V
ഘടകങ്ങൾ:
- Finger Vein Scanner: For advanced biometric access.
- ഡിജിറ്റൽ കീപാഡ്: For 4-6 digit combination code entry.
- താക്കോൽദ്വാരം: For mechanical override key access.
- ബാറ്ററി കമ്പാർട്ട്മെൻ്റ്: Located on the underside or rear of the unit.
- ഇന്റീരിയർ എൽഇഡി ലൈറ്റ്: Illuminates the safe's interior upon opening.
- മൗണ്ടിംഗ് പോയിൻ്റുകൾ: For securing the safe to a wall or desk.

Figure 3: Access Methods - Vein Recognition, Digital Keypad, Mechanical Key
5. സജ്ജീകരണം
5.1 ബാറ്ററി ഇൻസ്റ്റാളേഷൻ
- Locate the battery compartment, typically on the underside or rear of the safe.
- കമ്പാർട്ട്മെന്റ് കവർ തുറക്കുക.
- ശരിയായ പോളാരിറ്റി (+/-) ഉറപ്പാക്കിക്കൊണ്ട് 4 AA ബാറ്ററികൾ (ഉൾപ്പെടുത്തിയിട്ടില്ല) ഇടുക.
- ബാറ്ററി കമ്പാർട്ട്മെൻ്റ് കവർ സുരക്ഷിതമായി അടയ്ക്കുക.
- The safe will emit a beep, indicating successful power-up.
5.2 Initial Access and Programming
Upon first use, access the safe using the mechanical override key.
- Insert the mechanical key into the keyhole and turn it to unlock the safe.
- സുരക്ഷിതമായ വാതിൽ തുറക്കുക.
5.2.1 Setting a Digital Combination Code
- With the safe door open, locate the internal programming button (usually a small red or green button).
- Press the programming button. The indicator light on the keypad will illuminate.
- കീപാഡിൽ നിങ്ങൾക്ക് ആവശ്യമുള്ള 4-6 അക്ക കോഡ് നൽകുക.
- Press the programming button again to confirm. The safe will beep to confirm the new code.
- വാതിൽ അടയ്ക്കുന്നതിന് മുമ്പ് തുറന്നിരിക്കുമ്പോൾ പുതിയ കോഡ് പരിശോധിക്കുക.
5.2.2 Registering Finger Vein IDs
The safe can store up to 50 finger vein IDs.
- With the safe door open, press the programming button. The indicator light will illuminate.
- Place your finger firmly on the vein scanner. The scanner will light up and beep.
- Lift and reposition your finger slightly, then place it on the scanner again. Repeat this process 3-5 times from different angles to ensure a comprehensive scan.
- A successful registration will be indicated by a series of beeps.
- Repeat for additional fingers or users (up to 50).
- Test registered finger veins with the door open before closing it.

Figure 4: Finger Vein Recognition Technology
5.3 സേഫ് ഘടിപ്പിക്കൽ
The safe can be mounted to a wall or desk. Choose a secure location that is out of sight and reach of unauthorized persons.
- Select a suitable mounting location (e.g., under a desk, inside a cabinet, on a wall stud).
- Position the safe in the desired location and mark the mounting points through the pre-drilled holes on the safe's back or bottom.
- Drill pilot holes into the mounting surface using an appropriate drill bit size for the provided hardware.
- Align the safe with the drilled holes and secure it using the provided screws and anchors. Ensure the safe is firmly attached and does not wobble.

ചിത്രം 5: ഉദാamples of Wall and Desk Mounting Options
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
6.1 Opening with Finger Vein Recognition
- Place a registered finger firmly on the vein scanner.
- The scanner will light up, and the safe will emit a confirmation beep if the vein pattern is recognized.
- The safe door will automatically drop down, providing quick access.
6.2 Opening with Digital Keypad
- Enter your programmed 4-6 digit combination code on the keypad.
- The safe will emit a confirmation beep if the code is correct.
- The safe door will automatically drop down.
6.3 Opening with Mechanical Key
Use the mechanical key as a backup in case of battery failure or forgotten codes.
- Locate the keyhole cover (if present) and remove it.
- Insert the mechanical key into the keyhole and turn it to unlock the safe.
- The safe door will open.
6.4 സൈലൻ്റ് മോഡ്
The safe features a silent mode for discreet access. Refer to the safe's specific button layout for activating/deactivating silent mode (often a dedicated button or a combination press).
6.5 അലാറം മോഡ്
The safe is equipped with an audible alarm. This alarm may activate if multiple incorrect access attempts are made or if the safe is tampered with. Consult the safe's interface for specific alarm settings or deactivation procedures.
6.6 ഇന്റീരിയർ എൽഇഡി ലൈറ്റ്
The interior LED light automatically illuminates when the safe door opens, providing visibility in low-light conditions.
7. പരിപാലനം
7.1 ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ
When the low battery indicator (usually a flashing light or specific beep pattern) appears, replace all 4 AA batteries promptly. Use high-quality alkaline batteries for optimal performance.
7.2 വൃത്തിയാക്കൽ
സേഫിന്റെ പുറംഭാഗം മൃദുവായ, ഡി-ടച്ച് ഉപയോഗിച്ച് തുടയ്ക്കുക.amp cloth. Avoid using abrasive cleaners or solvents that could damage the finish or electronic components. Keep the finger vein scanner clean and free of debris.
7.3 Regular Function Check
Periodically test all access methods (finger vein, keypad, mechanical key) to ensure they are functioning correctly. This helps identify potential issues before they become critical.
8. പ്രശ്നപരിഹാരം
If you encounter issues with your MAXSafes 10002V, refer to the following common problems and solutions:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Finger vein not recognized | Improper finger placement, unregistered finger, dirty scanner, skin conditions (e.g., very dry, damaged). | Ensure firm and consistent finger placement. Re-register the finger, trying different angles. Clean the scanner. Try another registered finger or access method. |
| കീപാഡ് പ്രതികരിക്കുന്നില്ല. | Low batteries, incorrect code, keypad malfunction. | Replace batteries. Re-enter code carefully. Use mechanical key if necessary. |
| സുരക്ഷിതമായി തുറക്കുന്നില്ല | Low batteries, incorrect access, mechanical obstruction. | Replace batteries. Try all access methods. Check for any obstructions preventing the door from dropping. |
| കുറഞ്ഞ ബാറ്ററി സൂചകം | ബാറ്ററികൾ കുറവാണ്. | 4 AA ബാറ്ററികളും ഉടൻ മാറ്റിസ്ഥാപിക്കുക. |
9 സ്പെസിഫിക്കേഷനുകൾ
Detailed specifications for the MAXSafes Model 10002V:
- ബ്രാൻഡ്: MAXSafes
- മോഡൽ നമ്പർ: 10002V
- ഉൽപ്പന്ന അളവുകൾ: 11.1"D x 3.8"W x 13.8"H
- ഇനത്തിൻ്റെ ഭാരം: 9.55 പൗണ്ട്
- ലോക്ക് തരം: Biometric (Finger Vein), Electronic Combination Lock, Key
- നിറം: കറുപ്പ്
- ശേഷി: 8.7 പൗണ്ട്
- മെറ്റീരിയൽ: Carbon Steel (16 gauge)
- പ്രത്യേക സവിശേഷത: Sensor Light, Audible Alarm
- മൗണ്ടിംഗ് തരം: Wall Mount, Desk Mount
- UPC: 762736839353

Figure 6: Product Dimensions and Included Keys
10. വാറൻ്റിയും പിന്തുണയും
MAXSafes products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official MAXSafes webസൈറ്റ്. ഏതെങ്കിലും വാറന്റി ക്ലെയിമുകൾക്ക് വാങ്ങിയതിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.





