COSTWAY c93dfbb6-0896-4db9-8478-4489b3ca37ee

COSTWAY 30k Quad 4 Zone Mini Split Air Conditioner User Manual

Model: c93dfbb6-0896-4db9-8478-4489b3ca37ee

1. Introduction & Key Features

This manual provides essential information for the proper installation, operation, and maintenance of your COSTWAY 30k Quad 4 Zone Mini Split Air Conditioner. Please read it thoroughly before use and retain it for future reference.

പ്രധാന സവിശേഷതകൾ:

Diagram showing a house with multiple indoor mini-split units cooling different rooms to different temperatures.

Image: Multi-room cooling capability, showing different temperature zones in a house.

Outdoor unit operating in extreme cold and hot conditions.

Image: Outdoor unit designed to withstand extreme temperatures from -13°F to 125°F.

Diagram showing a 4-zone AC unit for multiple room use with independent control.

Image: Independent temperature control for each of the four zones.

2. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Proper installation is crucial for the safe and efficient operation of your mini split system. A professional HVAC installer is required for this product.

പൊതു ഇൻസ്റ്റാളേഷൻ മാർഗ്ഗനിർദ്ദേശങ്ങൾ:

പാക്കേജ് ഉള്ളടക്കം:

Diagram showing all components included in the package: outdoor unit, indoor units, remote controls, wall sleeves, drain hoses, copper connection pipes, mounting plates, communication wires, screw kits, tape, putty, and wall caps.

ചിത്രം: കഴിഞ്ഞുview of included components for installation.

Detailed Installation Steps (Refer to Video):

Video: Detailed guide on how to install a split AC unit.

  1. പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധന: Before installation, check the status of indoor and outdoor units. Verify no parts are broken, the indoor cross-fan operates, and the remote controller functions. If the cross-fan does not operate, check and adjust it first.
  2. Gas Flow Check (Indoor Unit): Check for gas flow from the connector. If no gas is coming out, inspect the evaporator for any leakage.
  3. Indoor Unit Wiring: Unfix the electric box cover and connect the indoor and outdoor unit connection wires. Double-check the marks on the wires (1, 2, 3, and ground) to ensure correct and reliable wiring.
  4. Piping Direction & Case Cutting: Based on the installation location, decide the piping direction and cut the face frame case. Clean and smooth the case gap to prevent damage to the pipes.
  5. Pipe Connection (Indoor Unit): Adjust the connection pipes, paying attention to the alignment of the horn. Control the wrench's strength to prevent nut rupture. Ensure no gas leakage after pipe connection.
  6. Drainage Pipe Connection: Connect the drainage pipe. It must be sealed with electrical tape to ensure no water leakage.
  7. Wrapping Pipes & Wiring: Wrap the refrigerant pipes, drainage hose, and wiring together. Retain pipe connectors for later leak detection.
  8. വാൾ പ്ലേറ്റ് ഇൻസ്റ്റാളേഷൻ: Install the wall plate, ensuring it is secure enough to hold the indoor unit.
  9. Mounting Indoor Unit: Pass pipes through the wall hole and securely fix the indoor unit onto the mounting plate.
  10. Outdoor Unit Mounting: Fix the outdoor unit on the mounting bracket. Use rubber feet to reduce vibration and noise.
  11. Refrigerant Pipes Cover: Open the refrigerant pipes cover on the outdoor unit.
  12. Refrigerant Pipe Connection (Outdoor Unit): Connect the refrigerant pipes similar to the indoor unit. Control wrench force to prevent nut breakage. Connect the pipe horn to the 2-way and 3-way valves straightly to prevent gas leakage.
  13. Electrical Control Box (Outdoor Unit): Open the electrical control box. Route the indoor/outdoor connection cable to the left hole and the power cord to the right hole. Connect the indoor and outdoor connection wires to the electric terminal, matching marks (1, 2, 3, N, L, and ground). Connect the power supply cable to the electric terminal. Ensure all wire connections are correct and reliable.
  14. Main Power Supply Connection: Connect the outdoor unit to the main power supply. Always switch off the main power supply before connecting. Ensure the AC unit has a separate leakage breaker.
  15. Vacuum & Leakage Detection: Connect the vacuum pump. First, connect one hose from the manifold low-pressure gauge to the outdoor unit service port on the three-way valve. Second, connect the manifold gauge to the vacuum pump. Then, connect the vacuum pump to the power supply. Switch on the vacuum pump and open the gauge low-pressure valve. For split AC, vacuum the unit for at least 15 minutes until the vacuum is maintained at -14.5psi. For R32 or R454B units, vacuum for 15-30 minutes with a pump capacity of 4-4.5CFM. Close the low-pressure valve on the manifold gauge, then switch off the vacuum pump. Hold pressure for 5 minutes; the compound gauge pointer should not exceed 0.73psi. If it rebounds more, check and repair the leakage point (most likely from the pipe connector). Open the outdoor unit low-pressure valve counterclockwise for 1/4 turn with a hexagonal wrench to fill the system with refrigerant, then close it after 5 seconds. Check all pipe connectors of indoor and outdoor units for leaks. If gas leakage is found, repair and tighten the pipe connection. Clean the connectors and wrap the indoor connector pipes. Seal the wall hole with sealing cement.
  16. അവസാന ഘട്ടങ്ങൾ: Keep the gauge at positive pressure and quickly remove the pressure hose from the outdoor unit service valve. Fully open the outdoor unit low-pressure and high-pressure valves with a hexagonal wrench. Reinstall the protective caps of the service port, low-pressure, and high-pressure valves, then reinstall the valves cover.

3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Your COSTWAY Mini Split Air Conditioner offers various modes and smart features for optimal comfort and energy efficiency.

Modes & Speeds:

Remote control displaying various modes and fan speeds for the mini split AC unit.

Image: Remote control showing available modes and fan speeds.

Illustration of 6 modes, 5 fan speeds, and additional features for customized comfort.

Image: Visual representation of powerful functions and customized comfort options.

Smart Control Features:

Family enjoying a cool room controlled by a smartphone app.

Image: Smart control via smartphone app.

Smartphone app interface for controlling the mini split AC unit.

Image: Smart APP Control for anytime, anywhere access.

Voice control integration with a smart speaker for comfortable living.

Image: Voice Control for a comfortable and smart life.

Hand holding a remote control for easy adjustment of the AC unit.

Image: Remote Control for easy and quick adjustment.

Couple sleeping peacefully with the AC unit in quiet sleep mode.

Image: Enjoy a restful night with Sleep Mode, 24-hour Timer, Low Noise, and Screen Off functions.

4. പരിപാലനം

പതിവ് അറ്റകുറ്റപ്പണികൾ നിങ്ങളുടെ എയർ കണ്ടീഷണറിന്റെ ദീർഘായുസ്സും കാര്യക്ഷമമായ പ്രകടനവും ഉറപ്പാക്കുന്നു.

ഫിൽട്ടർ വൃത്തിയാക്കൽ:

Hand washing a removable air filter under running water.

Image: Removable and washable filters for cleaner air.

5. പ്രശ്‌നപരിഹാരം

If you encounter any issues with your air conditioner, please refer to the following common troubleshooting tips. For more complex problems, contact customer support.

6 സ്പെസിഫിക്കേഷനുകൾ

Detailed technical specifications for your COSTWAY 30k Quad 4 Zone Mini Split Air Conditioner.

സ്പെസിഫിക്കേഷൻമൂല്യം
ബ്രാൻഡ്കോസ്റ്റ്‌വേ
മോഡൽ നമ്പർc93dfbb6-0896-4db9-8478-4489b3ca37ee
ശേഷി3 ടൺ (30000 BTU)
കൂളിംഗ് പവർ30000 ബ്രിട്ടീഷ് തെർമൽ യൂണിറ്റുകൾ
SEER2 റേറ്റിംഗ്23
HSPF2 റേറ്റിംഗ്10
വാല്യംtage208-230V
റഫ്രിജറൻ്റ്R32
ശബ്ദ നില30 ഡെസിബെൽ
ഇനത്തിൻ്റെ ഭാരം24.4 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ17.9"D x 41.2"W x 31.8"H
പ്രത്യേക സവിശേഷതകൾWiFi Enabled, Multiple Modes & Speeds
ഇൻസ്റ്റലേഷൻ തരംസ്പ്ലിറ്റ് സിസ്റ്റം
ഫോം ഫാക്ടർമിനി-സ്പ്ലിറ്റ്
നിറംവെള്ള
Table showing dimensions for indoor and outdoor units based on BTU.

Image: Dimensions for indoor and outdoor units.

Energy Guide label, SEER2 and HSPF2 ratings, and R32 refrigerant information.

Image: Energy efficiency ratings and refrigerant type.

7. വാറണ്ടിയും പിന്തുണയും

COSTWAY is committed to providing excellent customer service and product support.

വാറൻ്റി വിവരങ്ങൾ:

ഉപഭോക്തൃ പിന്തുണ:

അനുബന്ധ രേഖകൾ - c93dfbb6-0896-4db9-8478-4489b3ca37ee

പ്രീview Costway 1.5 Ton Ductless Mini Split Air Conditioner Installation and Operation Guide
Official installation and operation guide for Costway ductless mini-split air conditioners, featuring the 19 SEER2 18,000 BTU 1.5 Ton model with Heat Pump. Provides essential safety precautions, detailed dimensions, wiring guidance, and operational tips.
പ്രീview Costway 17 SEER2 Ductless Mini Split Air Conditioner Installation and Operation Guide
Comprehensive guide for installing and operating the Costway 17 SEER2 12,000 BTU 1 Ton Ductless Mini Split Air Conditioner with Heat Pump (208/230V, GHM0542). Includes safety precautions, installation notes, operational guidelines, system specifications, and remote control functionality.
പ്രീview Mini Split Air Conditioner User Manual: FP10293US, FP10302US, FP10318US, FP10324US, FP10404US, FP10412US, FP10518US, FP10524US
Comprehensive user manual for Costway Airtural Series Mini Split Air Conditioner Heater Ductless models. Covers operation, safety precautions, maintenance, troubleshooting, and installation for R32 refrigerant units.
പ്രീview Costway Limited Warranty Information for Air Conditioners
Comprehensive details on the Costway limited warranty, including coverage periods, exclusions, conditions, and service instructions for their air conditioning products. Covers models FP10293US, FP10302US, FP10318US, FP10324US.
പ്രീview Costway Mini Split Air Conditioner User Manual and Installation Guide
Comprehensive user manual and installation guide for Costway Mini Split Air Conditioners (FP10293US, FP10302US, FP10318US, FP10324US, FP10404US, FP10412US, FP10518US, FP10524US), covering operation, maintenance, safety, and troubleshooting.
പ്രീview Costway Limited Warranty Information
Details the Costway Limited Warranty for products, covering warranty periods, exclusions, conditions, and service instructions for models FP10293US, FP10302US, FP10318US, FP10324US.