1. ആമുഖം
This manual provides essential information for the safe and effective use of your WEST TUNE Laboratory Vacuum Filtration Pump, Model WTVP-10B. Please read this manual thoroughly before operating the device and retain it for future reference. This oilless diaphragm pump is designed for various laboratory applications requiring a reliable vacuum source, such as solvent filtration, distillation, vacuum drying, and extraction.

Figure 1: WEST TUNE Laboratory Vacuum Filtration Pump WTVP-10B. This image shows the compact design of the pump with its integrated vacuum meter and power switch on the front panel, and a metal handle on top for portability. Various accessories like a filter, connectors, and a rubber tube are also displayed.
2. സുരക്ഷാ നിർദ്ദേശങ്ങൾ
Always follow these safety precautions to prevent injury and damage to the equipment:
- Ensure the power supply matches the pump's requirements (refer to specifications).
- Do not operate the pump in wet or hazardous environments.
- Keep the pump away from heat sources and direct sunlight.
- Do not block the heat dissipation holes during operation to prevent overheating.
- Always disconnect the power before performing any maintenance or cleaning.
- Avoid direct contact with moving parts during operation.
- This pump is designed for laboratory use. Do not use it for purposes other than those specified.
- In case of malfunction, switch off the pump immediately and consult the troubleshooting section or contact support.

Figure 2: The pump features built-in safety mechanisms including over-temperature protection and short-circuit protection, ensuring reliable and safe operation. The image shows the side of the pump with an electrical cord being plugged in, highlighting the power input and safety icons.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
3.1 ഘടകങ്ങൾ

ചിത്രം 3: വിശദമായി view of the pump's components. The front panel includes a Vacuum Meter and a Metal Switch (power button). The top features a Metal Handle. The bottom has Shock-Absorbing Foot Pads. The rear panel shows the Gas Pipe connection, Muffler, Heat Dissipation Holes, and Power Input.
- മെറ്റൽ ഹാൻഡിൽ: എളുപ്പമുള്ള പോർട്ടബിലിറ്റിക്ക്.
- Vacuum Meter: Displays the current vacuum level.
- Metal Switch: പവർ ഓൺ/ഓഫ് ബട്ടൺ.
- Shock-Absorbing Foot Pads: പ്രവർത്തന സമയത്ത് സ്ഥിരത നൽകുകയും വൈബ്രേഷൻ കുറയ്ക്കുകയും ചെയ്യുക.
- ഗ്യാസ് പൈപ്പ് കണക്ഷൻ: Point for connecting the vacuum tubing.
- മഫ്ലർ: Reduces operational noise.
- താപ വിസർജ്ജന ദ്വാരങ്ങൾ: Ensure proper cooling of the internal components.
- പവർ ഇൻപുട്ട്: Connection point for the power cord.
3.2 ബോക്സിൽ എന്താണുള്ളത്
- WEST TUNE Laboratory Vacuum Filtration Pump (Model WTVP-10B)
- പവർ കോർഡ്
- റബ്ബർ ട്യൂബ്
- ഫിൽട്ടർ ചെയ്യുക
- കണക്ടറുകൾ (വിവിധ തരം)

Figure 4: The image displays the main vacuum pump unit along with its accessories: a power cord, a rubber tube, a filter, and various brass connectors, all essential for setting up and operating the pump.
4. സജ്ജീകരണം
- അൺപാക്ക് ചെയ്യുന്നു: പമ്പും എല്ലാ അനുബന്ധ ഉപകരണങ്ങളും പാക്കേജിംഗിൽ നിന്ന് ശ്രദ്ധാപൂർവ്വം നീക്കം ചെയ്യുക. എന്തെങ്കിലും കേടുപാടുകൾ ഉണ്ടോ എന്ന് പരിശോധിക്കുക.
- പ്ലേസ്മെൻ്റ്: Place the pump on a stable, level surface. Ensure adequate ventilation around the unit, especially for the heat dissipation holes. The shock-absorbing foot pads should be in full contact with the surface.
- ട്യൂബുകൾ ബന്ധിപ്പിക്കുക: Connect one end of the provided rubber tube to the Gas Pipe Connection on the pump. Secure it firmly.
- ആപ്ലിക്കേഷനുമായി ബന്ധിപ്പിക്കുക: Connect the other end of the rubber tube to your laboratory apparatus (e.g., filtration flask, distillation setup) requiring a vacuum. Use appropriate connectors if necessary.
- പവർ കണക്ഷൻ: Insert the power cord into the Power Input on the pump, then plug the other end into a suitable electrical outlet.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
- തയ്യാറാക്കൽ: Ensure all connections are secure and the pump is placed correctly.
- പവർ ഓൺ: Press the Metal Switch (power button) on the front panel to turn on the pump. The indicator light on the switch will illuminate.
- മോണിറ്റർ വാക്വം: Observe the Vacuum Meter to monitor the vacuum level being generated. The pump will quickly reach its ultimate vacuum of approximately -0.08 MPa.
- പ്രവർത്തനം: Allow the pump to operate for the duration required by your experimental procedure. The pump is designed for continuous operation for extended periods.
- പവർ ഓഫ്: Once your application is complete, press the Metal Switch again to turn off the pump.
- വിച്ഛേദിക്കുക: Carefully disconnect the tubing from your apparatus and the pump.

Figure 5: This image highlights the pump's performance characteristics, including strong suction, low noise operation, and the ability to work continuously for 24 hours, making it suitable for demanding laboratory tasks.
6. പരിപാലനം
The WEST TUNE WTVP-10B pump is designed for low maintenance due to its oilless diaphragm technology.
- എണ്ണ രഹിത പ്രവർത്തനം: This pump does not require oil changes, oil monitoring, or oil treatment, simplifying maintenance and ensuring a cleaner laboratory environment.
- വൃത്തിയാക്കൽ: Periodically wipe the exterior of the pump with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the pump's internal components.
- ഫിൽട്ടർ പരിശോധന: Regularly inspect the inline filter (if used) for any blockages or contamination. Replace the filter as needed to maintain optimal performance.
- ട്യൂബിംഗ്: Check the rubber tubing for cracks, kinks, or blockages. Replace damaged tubing to ensure proper vacuum integrity.
- സംഭരണം: When not in use for extended periods, store the pump in a clean, dry, and temperature-controlled environment.

Figure 6: This comparison highlights the key advantage of the WEST TUNE pump: its oil-free design requires no maintenance related to oil changes, unlike traditional oil-based pumps.
7. പ്രശ്നപരിഹാരം
നിങ്ങളുടെ പമ്പിൽ പ്രശ്നങ്ങൾ നേരിടുകയാണെങ്കിൽ, പൊതുവായ പ്രശ്നങ്ങളും പരിഹാരങ്ങളും അറിയാൻ താഴെ കൊടുത്തിരിക്കുന്ന പട്ടിക പരിശോധിക്കുക:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| പമ്പ് ഓണാക്കുന്നില്ല. | No power supply; faulty power cord; pump switch off. | Check power outlet; ensure power cord is securely connected; press the power switch. |
| Low or no vacuum. | Loose tubing connections; clogged filter; damaged tubing; internal pump issue. | Check all tubing connections for leaks; inspect and clean/replace filter; replace damaged tubing; contact support if problem persists. |
| അസാധാരണമായ ശബ്ദം അല്ലെങ്കിൽ വൈബ്രേഷൻ. | Pump not on a stable surface; internal component issue. | Ensure pump is on a flat, stable surface; check if shock-absorbing feet are intact. If noise persists, contact support. |
| പമ്പ് അമിതമായി ചൂടാകുകയും ഓഫാകുകയും ചെയ്യുന്നു. | Blocked heat dissipation holes; prolonged operation in high ambient temperature. | Ensure heat dissipation holes are clear; allow pump to cool down; operate in a well-ventilated area. |
8 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ | WTVP-10B |
| ടൈപ്പ് ചെയ്യുക | Oilless Diaphragm Vacuum Pump (Negative Pressure) |
| മോട്ടോർ പവർ | 15W |
| സക്ഷൻ നിരക്ക് | 10 എൽ/മിനിറ്റ് |
| ആത്യന്തിക വാക്വം | -0.08 എം.പി |
| ശബ്ദ നില | <60 ഡിബി |
| ഭാരം | 6 പൗണ്ട് (ഏകദേശം 2.7 കിലോഗ്രാം) |
| അളവുകൾ (L x W x H) | 8.66" x 5.12" x 6.69" (approximately 22 x 13 x 17 cm) |
| Valve Diaphragm Material | Premium Rubber |
| സുരക്ഷാ സവിശേഷതകൾ | Short Circuit Protection, Overload Protection, Over-Temperature Protection |

Figure 7: A visual representation of the pump's key specifications, including model number, power, suction rate, noise level, weight, dimensions, and safety features.
9. വാറൻ്റിയും പിന്തുണയും
Specific warranty details and direct support contact information are not provided within this manual. For warranty claims, technical assistance, or any questions regarding your WEST TUNE Laboratory Vacuum Filtration Pump, please refer to the product packaging, your purchase documentation, or contact the seller directly through the platform where the product was purchased.
You may also visit the official WEST TUNE store for general information: WEST TUNE Store on Amazon.