FOXWELL BT630, BT705 Plus

FOXWELL BT630 Bluetooth Battery Monitor & BT705 Plus Car Battery Tester User Manual

Models: BT630, BT705 Plus

1. ആമുഖം

This manual provides detailed instructions for the FOXWELL BT630 Bluetooth Battery Monitor with Shunt and the FOXWELL BT705 Plus Car Battery Tester. The BT630 offers real-time battery monitoring via Bluetooth, while the BT705 Plus is a comprehensive 12V and 24V car battery analyzer. Please read this manual thoroughly before operating the devices to ensure proper usage and safety.

2. ഉൽപ്പന്നം കഴിഞ്ഞുview

2.1 FOXWELL BT705 Plus Car Battery Tester

The BT705 Plus is designed for comprehensive battery health testing, supporting 12V and 24V systems. It performs various tests to assess the condition of different battery types, including Flooded (Regular), EFB, GEL, AGM Flat Plate, and Spiral batteries. It is suitable for a wide range of vehicles and equipment.

FOXWELL BT705 Plus performing a full battery health test

Image: The BT705 Plus display showing various battery health tests including State of Health (SOH), State of Charge (SOC), Charging Test, Voltage Test, Ripple Analysis, Cranking Test, Resistance Test, and Load Test.

FOXWELL BT705 Plus with 2.8 inch color LCD display

Image: The BT705 Plus features a 2.8-inch color LCD display for easier navigation and clearer results, offering step-by-step guidance during testing.

FOXWELL BT705 Plus compatibility with 12V and 24V batteries and various vehicle types

Image: The BT705 Plus is compatible with 12V and 24V batteries, including EFB, GEL, Flooded, and AGM types, and can be used for Cars, RVs, SUVs, ATVs, Motorcycles, Tractors, Trucks, Boats, Mowers, and Yachts.

2.2 FOXWELL BT630 Bluetooth Battery Monitor with Shunt

The BT630 is a Bluetooth-enabled battery monitor designed for real-time tracking of battery performance. It supports high-current monitoring up to 600A and a wide voltage range from 10V to 120V. This device is ideal for RVs, EVs, marine systems, off-grid setups, portable power stations, and outdoor devices, providing critical data through a dedicated mobile application.

FOXWELL BT630 app interface showing battery monitoring metrics

Image: The BT630 app displays real-time metrics such as Voltage, Current, Battery Level, Remaining Capacity, Estimated Time of Use, Estimated Full Time, Temperature, Power, Cumulative Charge, and Cumulative Discharge.

FOXWELL BT630 shunt with safety protection features

Image: The BT630 shunt features an 8-layer safety protection system, including safeguards against low voltagഇ, ഓവർ വോളിയംtage, discharge overcurrent, charging overcurrent, overpower, over temperature, low temperature, and low State of Charge (SoC).

FOXWELL BT630 high-precision design with 0.4% error shunt

Image: The BT630 is engineered for high precision, featuring a built-in shunt with an error margin of only ±0.4% for accurate measurements.

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

3.1 FOXWELL BT705 Plus Car Battery Tester Setup

  1. Cl കണക്റ്റുചെയ്യുകamps: Ensure the vehicle ignition is off. Connect the red positive (+) clamp ബാറ്ററിയുടെ പോസിറ്റീവ് ടെർമിനലിലേക്കും കറുത്ത നെഗറ്റീവ് (-) cl യിലേക്കുംamp നെഗറ്റീവ് ടെർമിനലിലേക്ക്.
  2. പവർ ഓൺ: The BT705 Plus will power on automatically once connected to the battery.
  3. ബാറ്ററി തരം തിരഞ്ഞെടുക്കുക: Use the navigation buttons to select the correct battery type (e.g., Flooded, EFB, GEL, AGM) from the menu.

3.2 FOXWELL BT630 Bluetooth Battery Monitor with Shunt Installation

The BT630 requires careful installation of the shunt for accurate monitoring. Professional installation is recommended if you are unfamiliar with electrical systems.

  1. ഷണ്ട് മൌണ്ട് ചെയ്യുക: Choose a dry, secure location near the battery bank for mounting the shunt. Ensure good ventilation.
  2. ബാറ്ററി വിച്ഛേദിക്കുക: Before wiring, disconnect the negative terminal of your battery bank to prevent electrical hazards.
  3. ഷണ്ട് വയർ ചെയ്യുക:
    • Connect the main negative cable from your battery bank to the 'BATTERY' terminal of the shunt.
    • Connect the main negative cable from your load/charger system to the 'LOAD' terminal of the shunt.
    • Connect the small positive wire from the BT630 unit to the positive terminal of your battery bank.
    • Connect the small negative wire from the BT630 unit to the 'BATTERY' terminal of the shunt (or a dedicated negative terminal on the shunt if available for the monitor).
  4. ബാറ്ററി വീണ്ടും ബന്ധിപ്പിക്കുക: Once all wiring is secure, reconnect the main negative terminal of your battery bank.
  5. ആപ്പ് ഇൻസ്റ്റാളേഷനും ജോടിയാക്കലും: Download the dedicated BMS app from your device's app store. Enable Bluetooth on your mobile device and pair with the BT630 monitor. Follow the in-app instructions for initial setup and calibration.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

4.1 Operating the FOXWELL BT705 Plus Car Battery Tester

  1. പ്രധാന മെനു: After powering on, the main menu will appear. Use the 'MENU' and arrow buttons to navigate.
  2. Select Test: Choose the desired test from options such as 'Battery Test', 'Cranking Test', 'Charging Test', 'Voltage Test', 'Ripple Analysis', 'Resistance Test', or 'Load Test'.
  3. ഓൺ-സ്ക്രീൻ നിർദ്ദേശങ്ങൾ പിന്തുടരുക: The device provides step-by-step guidance for each test. For example, during a 'Cranking Test', it will prompt you to start the engine.
  4. View ഫലങ്ങൾ: After the test is complete, the results will be displayed on the screen. Interpret the State of Health (SOH), State of Charge (SOC), and other relevant metrics.
  5. Print/Save Results: If connected to a printer or computer (optional), you may be able to print or save test reports.

4.2 Operating the FOXWELL BT630 Bluetooth Battery Monitor

  1. ആപ്പ് സമാരംഭിക്കുക: Open the dedicated BMS app on your paired mobile device.
  2. തത്സമയ നിരീക്ഷണം: The app will display real-time battery metrics including SOC%, Voltage, Current, Remaining Capacity, Power, Temperature, Estimated Runtime, and Charge/Discharge History.
  3. Data Graphs: View historical data and trends in clear graphical format to understand battery performance over time.
  4. ഇഷ്ടാനുസൃതമാക്കാവുന്ന അലേർട്ടുകൾ: Set up alerts for various parameters such as over/under-voltage, overcurrent, overpower, and temperature extremes. The app can notify you when these thresholds are met.
  5. Power Cutoff (Optional): If an external relay is integrated, the app can be configured to trigger a power cutoff based on predefined safety parameters.
  6. കാലിബ്രേഷൻ: The BT630 features dual-calibration precision. It uses an automatic error calibration system based on a long-term model database. Manual calibration for Voltage, Current, and Temperature can also be performed via the app for fine-tuning.
FOXWELL BT630 dual calibration process, auto and manual

Image: The BT630 supports both automatic SOC calibration and manual calibration for Voltage, Current, and Temperature, allowing for precise adjustments.

5. പരിപാലനം

5.1 പൊതു പരിചരണം

  • Keep both devices clean and dry. Use a soft, damp cloth to wipe surfaces. Do not use abrasive cleaners or solvents.
  • ഉപയോഗത്തിലില്ലാത്തപ്പോൾ നേരിട്ടുള്ള സൂര്യപ്രകാശത്തിൽ നിന്നും കടുത്ത താപനിലയിൽ നിന്നും അകന്ന് തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് ഉപകരണങ്ങൾ സൂക്ഷിക്കുക.
  • ഉപകരണങ്ങൾ താഴെയിടുകയോ ശക്തമായ ആഘാതങ്ങൾക്ക് വിധേയമാക്കുകയോ ചെയ്യുന്നത് ഒഴിവാക്കുക.

5.2 BT705 Plus Maintenance

  • Inspect the test clamps and cables regularly for any signs of damage, fraying, or corrosion. Replace if necessary.
  • Ensure the display screen is free from scratches or cracks that could impair readability.

5.3 BT630 Maintenance

  • Periodically check all wiring connections to the shunt and the BT630 unit to ensure they are secure and free from corrosion.
  • Ensure the shunt's ventilation holes are clear of debris to maintain optimal thermal management.
  • Keep the mobile app updated to the latest version for optimal performance and new features.

6. പ്രശ്‌നപരിഹാരം

  • Device Not Powering On (BT705 Plus): cl ഉറപ്പാക്കുകamps are correctly and securely connected to the battery terminals. Check battery voltage; if too low, the device may not power on.
  • Inaccurate Readings (BT630): Verify all shunt wiring connections are correct and tight. Perform a manual calibration via the app if automatic calibration does not resolve the issue. Ensure the app is updated.
  • Bluetooth Connectivity Issues (BT630): Ensure Bluetooth is enabled on your mobile device. Restart both the BT630 (by temporarily disconnecting power) and your mobile device. Ensure the BT630 is within range.
  • Test Failure/Error Message (BT705 Plus): Refer to the specific error code or message displayed on the screen. This often indicates an issue with the battery, connections, or test parameters. Recheck connections and battery condition.
  • Proactive Monitoring: The BT630's visualized data graphs can help detect potential battery issues up to 30 days in advance by monitoring trends in current, voltage, and temperature. Regularly review these graphs to preempt failures.

7 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്ഫോക്സ്വെൽ
മോഡൽ നമ്പറുകൾBT630, BT705 Plus
ASINB0FBRK7C78
BT630 വാല്യംtagഇ റേഞ്ച്10V മുതൽ 120V വരെ
BT630 Current Monitoring600A വരെ
BT630 Shunt Error±0.4%
BT630 Power Consumption0.4W (ultra-low)
BT630 Safety Protection8-layer (Over/Under-voltage, Overcurrent, Overpower, Over/Low-temperature, Low SOC)
BT705 Plus Voltagഇ അനുയോജ്യത12V & 24V
BT705 Plus Display2.8-ഇഞ്ച് കളർ എൽസിഡി
ആദ്യ തീയതി ലഭ്യമാണ്ജൂൺ 2, 2025

8. വാറൻ്റിയും പിന്തുണയും

For warranty information, please refer to the documentation included with your product or visit the official FOXWELL webസൈറ്റ്. വാറന്റി നിബന്ധനകളും വ്യവസ്ഥകളും പ്രദേശത്തിനും ഉൽപ്പന്നത്തിനും അനുസരിച്ച് വ്യത്യാസപ്പെടാം.

For technical support, troubleshooting assistance, or further inquiries, please visit the official FOXWELL support page or contact their customer service directly. Contact details are typically available on the FOXWELL webസൈറ്റ്.

അനുബന്ധ രേഖകൾ - BT630, BT705 Plus

പ്രീview Foxwell F1000B OBDII & Battery Tester User Manual | Diagnostics & Battery Health
Comprehensive user manual for the Foxwell F1000B OBDII & Battery Tester. Learn how to diagnose vehicle faults, read/erase DTCs, view live data, and test battery health with this detailed guide.
പ്രീview FOXWELL NT301PLUS OBDII & Battery Tester User's Guide | Diagnostics & Battery Analysis
Comprehensive user guide for the FOXWELL NT301PLUS OBDII & Battery Tester. Covers OBDII/EOBD diagnostics, battery testing, setup, safety, and warranty information for automotive professionals and enthusiasts.
പ്രീview ഫോക്‌സ്‌വെൽ NT301Plus ക്വിക്ക് സ്റ്റാർട്ട് ഗൈഡ്: വാഹന ഡയഗ്നോസ്റ്റിക്സും ബാറ്ററി പരിശോധനയും
വാഹന കണക്ഷൻ, ടെസ്റ്റർ സവിശേഷതകൾ, സോഫ്റ്റ്‌വെയർ അപ്‌ഡേറ്റുകൾ, I/M വീണ്ടെടുക്കൽ, പരിശോധനാ ഫല പ്രിന്റിംഗ്, ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്ന ഫോക്‌സ്‌വെൽ NT301Plus OBDII & ബാറ്ററി ടെസ്റ്ററിനായുള്ള സമഗ്ര ഗൈഡ്.
പ്രീview Foxwell BT100 12V Automotive Battery Analyzer User's Guide
Comprehensive user guide for the Foxwell BT100 12V Automotive Battery Analyzer, detailing its features, specifications, operation procedures, safety precautions, and warranty information. Learn how to test 6V & 12V batteries for various types like flooded, AGM, and gel.
പ്രീview ഫോക്സ്വെൽ BT715 ബാറ്ററി അനലൈസർ ഉപയോക്തൃ ഗൈഡ്
Comprehensive user guide for the Foxwell BT715 Battery Analyzer, detailing its operation, features, specifications, warranty, and safety instructions for automotive battery testing.
പ്രീview FOXWELL NT630Plus ABS & എയർബാഗ് റീസെറ്റ് ടൂൾ യൂസർ മാനുവൽ
FOXWELL NT630Plus ABS & എയർബാഗ് റീസെറ്റ് ടൂളിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, അതിന്റെ സവിശേഷതകൾ, പ്രവർത്തനം, സുരക്ഷാ നിർദ്ദേശങ്ങൾ, വാറന്റി വിവരങ്ങൾ എന്നിവ വിശദമാക്കുന്നു.