1. ആമുഖം
The Redodo 12V/24V 150A Adjustable Battery Dual Isolator (VSR) is designed to manage two battery systems, ensuring your starting battery remains charged while allowing auxiliary batteries to power accessories. This device automatically connects and disconnects batteries based on voltage thresholds, providing efficient power distribution and protection.
പ്രധാന സവിശേഷതകളിൽ ഇവ ഉൾപ്പെടുന്നു:
- ക്രമീകരിക്കാവുന്ന വോള്യംtage settings for 12V or 24V systems, compatible with lithium (LiFePO4) and lead-acid batteries.
- Built-in LCD display for real-time voltagഇ, നിലവിലെ നിരീക്ഷണം.
- Emergency reverse charge switch for starting the engine from the house battery.
- Multi-layered safeguards: over-voltage, over-temperature, and reverse-current protection.
- Compact design for easy installation in various vehicles and marine systems.

Image 1: The Redodo 12V/24V 150A Adjustable Battery Dual Isolator. This image shows the compact black unit with an LCD display and connection terminals.
2. ബോക്സിൽ എന്താണുള്ളത്?
അൺപാക്ക് ചെയ്യുമ്പോൾ, എല്ലാ ഘടകങ്ങളും ഉണ്ടെന്ന് ദയവായി പരിശോധിക്കുക:
- 1x Redodo 12V/24V 150A Adjustable Battery Dual Isolator
- 1x ഉപയോക്തൃ മാനുവൽ
- 4x മൗണ്ടിംഗ് സ്ക്രൂകൾ

Image 2: Contents of the product box, including the battery isolator, user manual, and mounting screws.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview നിയന്ത്രണങ്ങളും
ഉപകരണത്തിന്റെ ഘടകങ്ങളും നിയന്ത്രണങ്ങളും സ്വയം പരിചയപ്പെടുത്തുക:

Image 3: Labeled diagram of the Redodo Battery Isolator showing the LCD display, power button, adjustment buttons, set/enter button, and reverse charge button.
- പവർ ബട്ടൺ: യൂണിറ്റ് ഓണാക്കുകയോ ഓഫാക്കുകയോ ചെയ്യുന്നു.
- മുകളിലേക്കുള്ള അമ്പടയാള ബട്ടൺ: Used to navigate previous choices or increase values during setting adjustments.
- താഴേക്കുള്ള അമ്പടയാള ബട്ടൺ: Used to navigate next choices or decrease values during setting adjustments.
- Set/Enter Button: Confirms selections or enters setting modes.
- Reverse Charge Button: Activates the emergency reverse charge function. When pressed, the house battery will charge the starting battery for 60 seconds if its voltage is higher, enabling emergency engine start.
- LCD ഡിസ്പ്ലേ: തത്സമയ വോളിയം കാണിക്കുന്നുtage and current. When connected, it alternates between voltage and current every second. When disconnected, short press the Set/Enter button to cycle through the voltages.
4. ഇൻസ്റ്റലേഷൻ
Proper installation is crucial for the safe and efficient operation of your dual battery isolator. This device is suitable for RVs, marine vessels, trucks, and off-road vehicles.

ചിത്രം 4: ഉദാamples of versatile applications for the Redodo Battery Isolator, including RVs, marine boats, trucks, and off-road vehicles.
4.1. വയറിംഗ് ഡയഗ്രം
The following diagram illustrates a typical wiring setup for the Redodo Dual Battery Isolator:

Image 5: A detailed wiring diagram showing the connection of the alternator, starting battery, adjustable dual battery isolator, house battery, fuse, DC load, and ground.
- Connect the alternator to the starting battery.
- Connect the starting battery to one terminal of the Adjustable Dual Battery Isolator.
- Connect the house battery to the other terminal of the Adjustable Dual Battery Isolator.
- Ensure a fuse is installed between the alternator/starting battery and the isolator, and between the house battery and any DC loads.
- Connect the ground wire from the isolator to a common ground point.
- The Adjustable Dual Battery Isolator automatically connects/disconnects based on the starter battery voltage.
- When connected, the starter and house batteries charge in parallel.
- When disconnected, the starter and house batteries discharge separately.
4.2. മൗണ്ടിംഗ്
Mount the isolator in a secure, dry location away from direct heat or excessive vibration. Use the provided mounting screws to fix the unit firmly.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
5.1. പ്രാരംഭ പവർ ഓൺ
After installation, press the Power Button to turn on the unit. The LCD display will illuminate, showing the current voltage and cycling through voltage and current readings if connected.
5.2. ബാറ്ററി നില നിരീക്ഷിക്കൽ

Image 6: Close-up of the LCD display showing real-time voltage and current tracking. The display alternates between voltage and current every second when connected.
The built-in LCD display provides real-time information:
- ബന്ധിപ്പിച്ച സംസ്ഥാനം: The display will alternately show voltage and current every second.
- Disconnected State: Short press the Set/Enter button to cycle through the voltages of both batteries.
5.3. വോളിയം ക്രമീകരിക്കുന്നുtagഇ ത്രെഷോൾഡുകൾ
The isolator features adjustable voltage settings to accommodate various battery types (e.g., LiFePO4, lead-acid) and system voltages (12V/24V). Refer to the detailed settings menu in the full manual for specific instructions on how to enter programming mode and adjust connect/disconnect voltages using the Up/Down and Set/Enter buttons.

Image 7: The Redodo Battery Isolator is compatible with various battery types, including SLA, GEL, FLD, and LiFePO4 (LI) batteries.
5.4. Emergency Reverse Charge
In an emergency, if your starting battery is depleted, you can use the house battery to assist in starting the engine:
- Ensure the house battery has sufficient charge.
- Press the Reverse Charge button.
- The house battery will charge the starting battery for 60 seconds.
- Attempt to start the engine within this 60-second window.
6. പരിപാലനം
The Redodo Battery Dual Isolator is designed for minimal maintenance. Regular checks include:
- എല്ലാ വയറിംഗ് കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും തുരുമ്പെടുക്കലിൽ നിന്ന് മുക്തമാണെന്നും ഉറപ്പാക്കാൻ ഇടയ്ക്കിടെ പരിശോധിക്കുക.
- യൂണിറ്റ് വൃത്തിയായി സൂക്ഷിക്കുക, പൊടിയോ അവശിഷ്ടങ്ങളോ ഇല്ലാതെ.
- അമിതമായി ചൂടാകുന്നത് തടയാൻ യൂണിറ്റിന് ചുറ്റും മതിയായ വായുസഞ്ചാരം ഉറപ്പാക്കുക.
No user-serviceable parts are inside the unit. Do not attempt to open or repair the isolator yourself.
7. പ്രശ്നപരിഹാരം
If you encounter issues with your Redodo Battery Dual Isolator, consider the following common troubleshooting steps:
- ഡിസ്പ്ലേ ഇല്ല/പവർ ഇല്ല:
- എല്ലാ പവർ കണക്ഷനുകളും ഫ്യൂസുകളും പരിശോധിക്കുക.
- പവർ ബട്ടൺ അമർത്തിയെന്ന് ഉറപ്പാക്കുക.
- ബാറ്ററി വോളിയം പരിശോധിക്കുകtage is within the operating range (12V/24V).
- Batteries Not Connecting/Disconnecting:
- വോളിയം എന്ന് പരിശോധിക്കുകtage thresholds are set correctly for your battery type and system voltage.
- വോളിയം പരിശോധിക്കുകtage of both batteries; the VSR will only connect when the starting battery reaches the set connect voltage.
- അയഞ്ഞ കണക്ഷനുകൾക്കോ കേടുപാടുകൾക്കോ വേണ്ടി വയറിംഗ് പരിശോധിക്കുക.
- അമിത ചൂടാക്കൽ:
- Ensure the unit is mounted in a location with sufficient airflow.
- Check for excessive current draw or short circuits in the system.
For persistent issues, please contact Redodo customer support.
8 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| മോഡൽ | VSR 12V/24V 150A |
| വാല്യംtagഇ അനുയോജ്യത | 12V / 24V (Adjustable) |
| പരമാവധി കറൻ്റ് | 150എ |
| വോളിയം ബന്ധിപ്പിക്കുകtagഇ (സ്ഥിരസ്ഥിതി) | 13.4V (12V system) / 26.8V (24V system) |
| വോളിയം വിച്ഛേദിക്കുകtagഇ (സ്ഥിരസ്ഥിതി) | 12.8V (12V system) / 25.6V (24V system) |
| ബാറ്ററി അനുയോജ്യത | LiFePO4, Lead-Acid (SLA, GEL, FLD) |
| പ്രദർശിപ്പിക്കുക | എൽസിഡി (വാല്യംtage, നിലവിലുള്ളത്) |
| അളവുകൾ | 4.09 x 3.15 x 1.65 ഇഞ്ച് |
| ഭാരം | 11.3 ഔൺസ് |
| സംരക്ഷണ സവിശേഷതകൾ | ഓവർ-വോളിയംtage, Over-temperature, Reverse-current |

Image 8: Visual representation of the safety protections: over-voltage, over-temperature, and reverse-current protection.
9. വാറൻ്റിയും പിന്തുണയും
9.1. വാറൻ്റി വിവരങ്ങൾ
The Redodo 12V/24V 150A Adjustable Battery Dual Isolator comes with a 5 വർഷത്തെ ഗ്യാരണ്ടി from the date of purchase, covering defects in materials and workmanship under normal use. This warranty does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.
9.2. ഉപഭോക്തൃ പിന്തുണ
For technical assistance, warranty claims, or any questions regarding your product, please contact Redodo customer support. We aim to provide a 24-hour response to all inquiries.
You can find contact information on the official Redodo webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ വാങ്ങൽ പ്ലാറ്റ്ഫോം വഴി.
- Redodo Official Webസൈറ്റ്: www.redodo.com