GODIYMODULES With RS485 version

GODIYMODULES Digital Analog Signal Input Panel Meter with RS485 Version User Manual

Model: With RS485 version

1. ആമുഖം

This manual provides detailed instructions for the installation, operation, and configuration of the GODIYMODULES Digital Analog Signal Input Panel Meter with RS485 Version. This universal analog input display meter is designed to work with various sensors that provide analog output, such as temperature transmitters, frequency converters, motor speed sensors, pressure sensors, and liquid level sensors, to display actual physical quantities.

The meter supports both current and voltage inputs and is adaptable to standard ranges like 0-10V, 2-10V, 0-20mA, and 4-20mA. It can also be configured for other input ranges within 0-10V or 0-20mA by adjusting bias and gain parameters. By default, the display shows a percentage, but users can define their own display range.

GODIYMODULES Digital Analog Signal Input Panel Meter with RS485 Version

ചിത്രം 1.1: മുൻഭാഗം view of the GODIYMODULES Digital Analog Signal Input Panel Meter with RS485 Version, displaying "90.0".

2 പ്രധാന സവിശേഷതകൾ

3. പാക്കേജ് ഉള്ളടക്കം

പാക്കേജിൽ ഉൾപ്പെടുന്നു:

4 സാങ്കേതിക സവിശേഷതകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
മോഡൽWith RS485 version
ഇൻപുട്ട് സിഗ്നൽ തരങ്ങൾ0-10V, 2-10V, 0-20mA, 4-20mA (configurable)
Power Supply (Standard/RS485)DC6~25V
Power Supply (Relay Output Version)DC8~25V
Power Consumption (Standard/RS485)24V/40mA
Power Consumption (Relay Output Version)24V/50mA
അളവുകൾ3.94 x 1.98 x 0.79 ഇഞ്ച്
ഭാരം1.76 ഔൺസ്

5. ഇൻസ്റ്റലേഷനും വയറിംഗും

Proper wiring is crucial for the correct operation of the meter. Refer to the diagrams and descriptions below for connection details.

5.1. Wiring Terminals Overview

തിരികെ view of the meter showing wiring terminals and label

ചിത്രം 5.1: പിന്നിലേക്ക് view of the meter with wiring terminals and label. This image illustrates the physical layout of the connection points.

5.2. Port Signal Description

The following table details the function of each terminal port:

സിഗ്നൽവിശദീകരണം
PwrConnect to the positive pole of the power supply (Standard/RS485 version: DC6~30V; Relay output version: DC8~30V)
ജിഎൻഡിശക്തിയും സിഗ്നൽ ഗ്രൗണ്ടും
AiAnalog input signal configuration interface.
mACurrent-type analog input signal configuration interface. Short-circuit with Ai for current-type input.
485- (With RS485 version)RS485 signal negative
485+ (With RS485 version)RS485 signal positive
KA (With relay output version)Relay normally open contact output port
KB (With relay output version)Relay normally open contact output port

5.3. Common Wiring Diagrams

Refer to the following diagrams for typical wiring configurations based on your input signal type.

Common wiring diagrams for voltage input, current input, and two-wire current sensor

Figure 5.2: Common wiring diagrams. This image shows connections for Voltage Input, Current Input, and Two-Wire Current Sensor configurations.

  • വാല്യംtagഇ ഇൻപുട്ട്: പോസിറ്റീവ് വോള്യം ബന്ധിപ്പിക്കുകtage signal to 'Ai' and the negative to 'GND'. Power supply (PWR, GND) is also shown.
  • നിലവിലെ ഇൻപുട്ട്: Short-circuit 'Ai' and 'mA', then connect the positive current signal to 'mA' and the negative to 'GND'. RS485 connections (485+, 485-) are also indicated.
  • Two-Wire Current Sensor: Connect the sensor's positive output to 'PWR' and its negative output to 'Ai'. The meter's 'GND' is connected to the sensor's ground.

6. Operation and Parameter Settings

This section describes how to operate the meter and configure its various parameters using the front panel buttons.

6.1. ഇൻഡിക്കേറ്റർ ലൈറ്റുകൾ

6.2. Button and Display State Transition

The meter features a multi-level menu system for configuration. Use the സെറ്റ്, മുകളിലേക്കുള്ള അമ്പടയാളം, താഴേക്കുള്ള അമ്പടയാളം, ഒപ്പം OK buttons to navigate and adjust settings.

Button and digital tube display state transition diagram

Figure 6.1: Button and digital tube display state transition diagram. This diagram illustrates how to navigate through the menu levels (Monitoring, First-level, Second-level, Third-level) using the SET and OK buttons, and how to modify parameters using the Up/Down arrows.

പ്രത്യേക കുറിപ്പ്: When in the third-level menu, pressing the OK key saves the modified parameter values and returns to the previous menu level, with the parameter number automatically incremented by one. Pressing the സെറ്റ് key returns directly to the previous menu level without saving the modified parameter values. Holding down the Up or താഴേക്ക് key allows the adjustment values to change rapidly.

6.3. Parameter Group F0: Attendant Array Display

These parameters relate to the display and monitoring of the input value.

പരാമീറ്റർപാരാമീറ്ററിൻ്റെ പേര്Scope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F0-0Collected value monitoringMonitor the percentage of the current analog input value. Range: 0-100.0%വായിക്കാൻ മാത്രം
F0-1Display value monitoringIn the display value in "Monitoring Menu" is calculated by F0-0, F0-2~F0-4.വായിക്കാൻ മാത്രം
F0-2പ്രദർശന കൃത്യതThe number of decimal places displayed in the "Monitor Menu", range: 0-3.1വായിക്കുക/എഴുതുക
F0-3Show minimumIn the "Monitoring Menu", the value corresponding to "acquisition value" is 0%, the range: -1999~99990വായിക്കുക/എഴുതുക
F0-4Show maximumIn the "Monitoring Menu", the value corresponding to the "Acquisition Value" is 100.0%, the range: 1999~99991000വായിക്കുക/എഴുതുക
F0-5ഓഫ്‌ലൈൻ നില0: Not disconnected; 1: Disconnected. (Disconnection detection is set by F1-4) (starting from V2.10)വായിക്കാൻ മാത്രം

6.4. Parameter Group F1: Analog Configuration Parameters

These parameters configure the analog input signal processing.

പരാമീറ്റർപാരാമീറ്ററിൻ്റെ പേര്Scope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F1-0ഇൻപുട്ട് തരം തിരഞ്ഞെടുക്കൽ0: 0-10V or 0-20mA corresponds to 0-100.0%; 1: 2-10V or 4-20mA corresponds to 0-100.0%, and 0 when it is lower than 2V or 4mA.0വായിക്കുക/എഴുതുക
F1-1ഇൻപുട്ട് ഫിൽട്ടർ സമയംAnalog input filter time, range: 0-10.000s. The longer the filtering time, the stronger the filtering.0.200വായിക്കുക/എഴുതുക
F1-2ഇൻപുട്ട് നേട്ടംRange: 0-1000.0%.100.0വായിക്കുക/എഴുതുക
F1-3ഇൻപുട്ട് ഓഫ്സെറ്റ്-99.9~99.9%, with 10V or 20mA as 100.0%. Range: 0.0-100.0%. This value is based on 0-10V or 0-20mA as 0.0-100.0% as a reference (and F1-0 and gain offset are not related).0.0വായിക്കുക/എഴുതുക
F1-4Drop detection thresholdThe detection is not started if it is less than 0.5, and there is a hysteresis of ±0.3. When the input signal is lower than this value, the meter displays E.OfL. (Starting from V2.10)0.0വായിക്കുക/എഴുതുക
F1-5Enter the parameter setting selection0: Long press SET button for 3s to enter the parameter setting mode; 1: Keep pressing SET button for more than 3s, and Press OK to enter parameter setting mode0വായിക്കുക/എഴുതുക

6.5. Parameter Group F2: Relay Output Dosing (with Relay Output version)

These parameters are applicable only to meters with relay output functionality.

പരാമീറ്റർപാരാമീറ്ററിൻ്റെ പേര്Scope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F2-0Relay output status configurationWhen the output conditions are met, the relay output status: 0: No control (always open); 1: Relay closed; 2: Relay open (not satisfied Closed on condition)0വായിക്കുക/എഴുതുക
F2-1കണ്ടീഷൻ തരം0: greater than comparison value 1; 1: less than comparison value 2; 2: greater than comparison value 1 and less than comparison value 2.0വായിക്കുക/എഴുതുക
F2-2താരതമ്യ മൂല്യം 1Range: 0-100.0%.50.0വായിക്കുക/എഴുതുക
F2-3താരതമ്യ മൂല്യം 2Range: 0-100.0%.50.0വായിക്കുക/എഴുതുക
F2-4Hysteresis intervalIn order to prevent the relay output from operating frequently near the comparison value, hysteresis interval parameters are introduced. Range: 0.0%-80.0%.5.0വായിക്കുക/എഴുതുക
F2-5Relay status when offlineAfter setting F1-4, when the offline condition is reached, the relay output state. Note: This priority is higher than that of the comparison relay output. 0: Not used; 1: Relay is closed; 2: Relay is disconnected (starting from V2.10)0വായിക്കുക/എഴുതുക

Example of Hysteresis Interval: ഉദാample, if F2-1 (Condition type) is set to "0: greater than comparison value 1", F2-2 (Comparison value 1) to 50.0%, and F2-4 (Hysteresis interval) to 5.0%. When the power is on, if the collected value gradually increases and exceeds 50.0%+5.0%/2, the output condition is satisfied. If the collected value decreases, it needs to be less than 50.0%-5.0%/2 to reach the non-output condition.

7. RS485 Communication (with RS485 Version)

This section details the communication parameters and networking for the RS485 version of the meter.

7.1. Parameter Group F7: Communication Parameters and Software Version

പരാമീറ്റർപാരാമീറ്ററിൻ്റെ പേര്Scope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F7-0പ്രാദേശിക വിലാസംശ്രേണി: 1-2471വായിക്കുക/എഴുതുക
F7-1ബൗഡ് നിരക്ക്0:1200bps; 1: 2400bps; 2: 4800bps; 3: 9600bps; 4:19200bps; 5: 38400bps3വായിക്കുക/എഴുതുക
F7-2ഡാറ്റ ഫോർമാറ്റ്0:8,1, None (8 data bits, 1 stop bit, no parity); 1:8,1, Even (8 data bits, 1 stop bit, even parity); 2:8,1, Odd (8 data bits, 1 stop bit, odd parity); 3:8,2, None (8 data bits, 2 stop bits, no parity)0വായിക്കുക/എഴുതുക
F7-3പ്രതികരണ കാലതാമസംCommunication response delay time 0~500ms. Use above V1.025വായിക്കുക/എഴുതുക
F7-4ആശയവിനിമയ തരം0: The display table is a Modbus slave, and the user host can read the collected values of the display table; 1: The display table is a network slave between the tables, and can receive the display data of the display table set as the master; 2: The display table is the network host between the tables, and the display value is sent to the slave display table through the broadcast address; 3: The display table is the inter-table networking host, and the display value is sent to the slave by means of address polling.0വായിക്കുക/എഴുതുക

7.2. Communication Protocol and Method

The meter uses a Modbus-like protocol for communication. The following describes how to interact with the meter as a slave device.

7.2.1. Reading Collected Values from the Display Table

The user host can read the collected values (F0-0) and display values (F0-1) from the meter. The meter's display range is determined by F0-2 to F0-4. The Modbus register address for F0-0 is 0000H, and for F0-1 is 0001H. The collected value is 0-1000, corresponding to 0-100.0%. The display value is 0-1000, corresponding to the display range set by F0-2 to F0-4. The host can also read and write other parameters (F0-2 to F0-4, F1-0 to F1-5, F2-0 to F2-5, F7-0 to F7-4).

ExampLe: If the collected value F0-0 is 60.0%, the displayed value F0-1 is 60.0. The slave (HXDSBOXAI) response data for reading F0-0 and F0-1 would be:

മുകളിൽ പറഞ്ഞതിൽample, the read F0-0 and F0-1 are 0258H = 600, meaning the collected value F0-0 is 60.0%, and the displayed value F0-1 is 60.0.

7.3. Networking Description Between Tables

Through the network between meters, the display value of the data collected by the master meter can be transmitted to the slave meter for display through RS485. Only one master table can exist in a network, and there can be multiple slave tables. In use, only the master table needs to set the corresponding display range, and the slave table does not need to set the display range.

7.3.1. Main Table Sends Data Through Broadcast Mode Network Diagram

Diagram showing main table sending data via broadcast mode network

Figure 7.1: Main table sends data through broadcast mode network diagram. This diagram illustrates a master meter (Main table, F7-4 is 2) broadcasting data to multiple slave meters (From table, F7-4 is 1) over an RS485 total line.

7.3.2. Table Network Diagram of Sending Data Through Address Polling

Diagram showing table network sending data via address polling

Figure 7.2: Table network diagram of sending data through address polling. This diagram illustrates a primary master meter (F7-0 is 3, F7-4 is 3) polling data from multiple slave meters (F7-0 is 1, F7-4 is 1; F7-0 is 2, F7-4 is 1) over an RS485 total line.

കുറിപ്പ്: When the master meter sends data to the slave meter through address polling, only meters with the same address as the polled address will respond. All other meters will not respond. This ensures targeted communication in a multi-device network.

8. പരിപാലനം

9. പ്രശ്‌നപരിഹാരം

If issues persist after checking these points, consult the manufacturer's support or a qualified technician.

10. വാറൻ്റിയും പിന്തുണയും

For warranty information and technical support, please refer to the documentation provided with your purchase or contact GODIYMODULES customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.

അനുബന്ധ രേഖകൾ - With RS485 version

പ്രീview കമോർ ഡിഐപി 1500 V2 ഇന്റലിജന്റ് പെരിസ്റ്റാൽറ്റിക് പമ്പ് യൂസർ മാനുവൽ
കമോർ ഡിഐപി 1500 വി2 ഇന്റലിജന്റ് പെരിസ്റ്റാൽറ്റിക് പമ്പിനായുള്ള ഉപയോക്തൃ മാനുവൽ, അതിന്റെ സവിശേഷതകൾ, പ്രവർത്തന സാഹചര്യങ്ങൾ, രൂപം, പ്രവർത്തന രീതികൾ, ഫംഗ്ഷൻ മെനു, ബാഹ്യ നിയന്ത്രണങ്ങൾ, അളവുകൾ, ഫ്ലോ റേറ്റ് റഫറൻസ് എന്നിവ വിശദമാക്കുന്നു. വേഗത, ഫ്ലോ മോഡുകൾ, കാലിബ്രേഷൻ, ആശയവിനിമയ ക്രമീകരണങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview Aposun CHDS8A Series Process Panel Meter User Manual
User manual for the Aposun CHDS8A series process panel meter, detailing model numbers, technical specifications, wiring diagrams, and operational settings for temperature, pressure, weighting, resistance, current, and voltagഇ അളവുകൾ.
പ്രീview മൈപിൻ ഡി സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ | സ്പെസിഫിക്കേഷനുകളും വയറിംഗും
MYPIN D സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്ററിനായുള്ള സമഗ്ര നിർദ്ദേശ മാനുവൽ. DM8A, DK8A, DM8E തുടങ്ങിയ മോഡലുകളുടെ സ്പെസിഫിക്കേഷനുകൾ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണം, വയറിംഗ് ഡയഗ്രമുകൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview പാറ്റേഴ്‌സൺ ഇസി-മോട്ടോർ വയറിംഗ് ക്വിക്ക് സ്റ്റാർട്ട് ഗൈഡ്
പാറ്റേഴ്‌സൺ ഇസി-മോട്ടോറുകൾ വയറിംഗ് ചെയ്യുന്നതിനുള്ള ഒരു സംക്ഷിപ്ത ഗൈഡ്, പൂർണ്ണ വേഗതയ്‌ക്കുള്ള വിശദമായ കോൺഫിഗറേഷനുകൾ, ഓപ്‌ഷണൽ സ്പീഡ് കൺട്രോൾ, മൾട്ടി-മോട്ടോർ സജ്ജീകരണങ്ങൾ, അനലോഗ് ഇൻപുട്ടുകൾ (0-10V/4-20mA), മോഡ്ബസ് കമ്മ്യൂണിക്കേഷൻ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. ഡിപ്‌സ്വിച്ച് ക്രമീകരണങ്ങളും കണക്ഷൻ ഡയഗ്രമുകളും ഉൾപ്പെടുന്നു.
പ്രീview High Temperature Pressure Transmitter QDW90A-2 | Specifications & Installation Guide
Comprehensive technical specifications, selection guide, wiring diagrams, and installation considerations for the Qidian QDW90A-2 High Temperature Pressure Transmitter. Learn about its features, parameters, and safe installation practices.
പ്രീview YM3787 不锈钢叶轮式管道风速传感器 产品使用手册
INTOIOT YM3787 不锈钢叶轮式管道风速传感器详细使用手册,涵盖技术参数、产品选型、通讯协议(RS485、4-20mA、DC0-10V)、外形尺寸及典型应用。