1. ആമുഖം
The FNIRSI 2D15P is a versatile 3-in-1 device combining a 100MHz digital oscilloscope, a 19,999-count TRMS multimeter, and a 10MHz DDS signal generator. Designed for precision and ease of use, it features a 4.3-inch IPS touchscreen and robust architecture for various electrical testing and analysis applications.
2 സുരക്ഷാ വിവരങ്ങൾ
Always observe standard safety precautions when operating electrical testing equipment. Ensure proper probe connections and be aware of live voltage. Refer to local electrical safety guidelines. Do not operate the device if it appears damaged or malfunctioning. Always disconnect power to the circuit under test before making connections, especially when dealing with high voltages അല്ലെങ്കിൽ വൈദ്യുതധാരകൾ.
3. പാക്കേജ് ഉള്ളടക്കം
The FNIRSI 2D15P package includes the following items:
- FNIRSI 2D15P Scope DMM Unit
- P6100 Probe * 2
- മൾട്ടിമീറ്റർ ടെസ്റ്റ് ലീഡുകൾ
- അലിഗേറ്റർ ക്ലിപ്പ് കേബിൾ
- യുഎസ്ബി ഡാറ്റ കേബിൾ

Figure 3.1: FNIRSI 2D15P with included probes, test leads, and cables.
4. ഉൽപ്പന്നം കഴിഞ്ഞുview
4.1 ബാഹ്യ ഘടന
The device features a 4.3-inch IPS touchscreen and various controls for intuitive operation. Key components include:
- 4.3-ഇഞ്ച് IPS ഡിസ്പ്ലേ: Touch-enabled for interactive control.
- പവർ ഓൺ/ഓഫ് ബട്ടൺ: For device power management.
- Oscilloscope Channels (CH1, CH2): Yellow for Channel 1, Blue for Channel 2.
- Signal Generator Channel (GEN): Gray for DDS output.
- Vertical Sensitivity Adjustment Knob: Controls vertical scaling.
- Horizontal Timebase Adjustment Knob: Controls horizontal scaling.
- വാല്യംtage Offset/Cursor Adjustment Knob: Adjusts waveform position and cursor.
- Single Trigger Button: For capturing single events.
- Auto Trigger Button: For automatic waveform display.
- Function Button Area: Includes Cursor, Display, Meas, Save, Math, 50%, CH1, CH2, Trigger, DDS, Run, Menu.
- Trigger Level/Delay Time Control Knob: Adjusts trigger parameters.
- Restart Button Hole: ഉപകരണം പുനഃസജ്ജമാക്കുന്നതിന്.

ചിത്രം 4.1: മുൻഭാഗം view of the FNIRSI 2D15P, highlighting the display and control interface.
4.2 പിൻഭാഗം View
The rear of the device includes essential ports and features for power and stability.
- പവർ ഇൻ്റർഫേസ്: Supports Type-C fast charging, rated 12V, 1A.
- Low-noise Cooling Fan: Ensures stable operation without interference.
- മടക്കാവുന്ന സ്റ്റാൻഡ്: Provides stable support for safe use.
- Standard 1/4-inch Screw Mount: For mounting options.

ചിത്രം 4.2: പിൻഭാഗം view of the FNIRSI 2D15P, showing the cooling fan and adjustable anti-slip stand.
5. സജ്ജീകരണം
5.1 പ്രോബ് കാലിബ്രേഷൻ
Before taking measurements, it is recommended to calibrate the oscilloscope probes for accurate readings.
- Set the probe switch to 10X.
- On the oscilloscope, ensure the probe attenuation setting is also 10X (Vertical menu).
- Connect the probe to the calibration port (usually a square wave output).
- Press the 'Auto' button on the oscilloscope.
- Adjust the probe's compensation (usually a small screw on the probe body) until a clean square wave is displayed on the screen.
Video 5.1: Demonstrates probe calibration and various oscilloscope settings (0:11-0:45 for calibration).
5.2 ചാനൽ ക്രമീകരണങ്ങൾ
Configure the input channels (CH1, CH2) for your specific measurement needs.
- Tap CH1 or CH2 to enable/disable the channel display.
- Adjust probe attenuation (1X, 10X, 100X) to match your physical probe.
- Select coupling method (AC, DC) based on the signal type.
- Enable/disable the 20MHz bandwidth limit for noise reduction.
5.3 ട്രിഗർ ക്രമീകരണങ്ങൾ
ട്രിഗർ സിസ്റ്റം ആവർത്തിച്ചുള്ള തരംഗരൂപങ്ങളെ സ്ഥിരപ്പെടുത്തുകയും സിംഗിൾ-ഷോട്ട് ഇവന്റുകൾ പകർത്തുകയും ചെയ്യുന്നു.
- Select the trigger channel (CH1 or CH2).
- Choose trigger edge (Rising, Falling, Both).
- Set trigger mode (Auto, Normal, Single).
- Adjust the trigger level and delay time using the dedicated knob.
5.4 ഓട്ടോമാറ്റിക് അഡ്ജസ്റ്റ്മെൻ്റ്
After connecting a signal source, press the 'Auto' button for automatic measurement and display of the waveform.
5.5 Waveform Scaling and Shift
Manually adjust the time base and vertical sensitivity knobs to scale the waveform. The voltage offset knob moves the waveform vertically.
5.6 കഴ്സർ അളവ്
Press 'Cursor' to enable cursor settings. Select and move dashed lines to measure specific points on the waveform. Measurement values appear in the top-left corner.
5.7 ഡിസ്പ്ലേ ക്രമീകരണങ്ങൾ
The 'Display' button allows adjustment of grid brightness, waveform brightness, grid type, waveform type (vector/point), and color temperature settings.
5.8 Parameter Display
Press 'Meas' to open measurement parameter settings. The device supports 13 parameter displays, which can be individually turned on or off.
5.9 Waveform Saving
Short press 'Save' to save a waveform screenshot. Saved images can be viewed from the menu.
5.10 One-Key Centering
A short press of the '50%' button centers the channel position, trigger level, and time base automatically.
5.11 യുഎസ്ബി പങ്കിടൽ
Enable USB sharing to connect the device to a computer via a data cable for exporting screenshots and firmware updates.
6 ഓപ്പറേറ്റിംഗ് മോഡുകൾ
6.1 ഓസിലോസ്കോപ്പ് പ്രവർത്തനം
The oscilloscope function allows for detailed waveform analysis in various applications.

ചിത്രം 6.1: ഉദാamples of oscilloscope applications, including LIN Bus troubleshooting, audio signal analysis, and power ripple detection.
Normal Trigger Mode
In normal trigger mode, the oscilloscope waits for a trigger event before displaying a waveform. If no trigger event occurs, the screen remains blank or displays the last triggered waveform.
സിംഗിൾ ട്രിഗർ മോഡ്
Single trigger mode is used to capture non-repetitive or transient signals. The oscilloscope waits for a trigger event, captures one waveform, and then stops. This allows for detailed analysis of a single event.
Video 6.2: Demonstrates how to test AC mains, SMPS, and crystal oscillators using the oscilloscope function.
6.2 മൾട്ടിമീറ്റർ പ്രവർത്തനം
The integrated multimeter provides 19,999 TRMS counts for various electrical measurements.

Figure 6.3: Multimeter functions including capacitance, resistance, continuity, diode, DC voltagഇ, എസി വോള്യംtage, DC current, and AC current measurements.
ഓട്ടോ മോഡ്
In Auto mode, the multimeter automatically detects the type of measurement and displays the reading, along with max/min values and a data fluctuation curve.
ഡിസി വോളിയംtagഇ അളവ്
Connect the multimeter test leads to the DC voltage source. The device will display the DC voltagഇ വായന.
Video 6.4: Demonstrates how to measure battery voltage using the oscilloscope and multimeter functions.
എസി വോളിയംtagഇ അളവ്
Connect the multimeter test leads to the AC voltage source. The device will display the AC voltagഇ വായന.
പ്രതിരോധം അളക്കൽ
Connect the multimeter test leads across the component to measure its resistance.
തുടർച്ചയായ പരിശോധന
Use the continuity test to check for open or closed circuits. The device will emit a buzzer sound for continuity.
ഡയോഡ് ടെസ്റ്റ്
Measure the forward voltage drop of a diode using the diode test function.
കപ്പാസിറ്റൻസ് അളക്കൽ
Measure the capacitance of a component by connecting the test leads across it.
DC നിലവിലെ അളവ്
For low current (mA range), plug the red probe into the mA port. For high current (A range), switch the red probe to the 10A range. Connect the multimeter in series with the circuit to measure DC current.
എസി കറന്റ് മെഷർമെന്റ്
For low current (mA range), plug the red probe into the mA port. For high current (A range), switch the red probe to the 10A range. Connect the multimeter in series with the circuit to measure AC current.
6.3 Signal Generator Operation
The DDS signal generator can output various waveforms up to 10MHz.

Figure 6.5: Available waveforms from the DDS signal generator: Sine, Square, Ramp, DC, Noisy, Half-Wave, Full-Wave, Positive Step, and Negative Step.
- Press 'DDS' or tap 'DS' on the screen to enter the signal generator interface.
- Select the desired waveform type (Sine, Square, Ramp, DC, Noisy, Half-Wave, Full-Wave, Positive Step, Negative Step).
- Adjust frequency (0-10MHz), amplitude (0.1-3Vpp), and duty cycle (0-100%) as needed.
- Connect the output of the signal generator (GEN port) to the circuit or device under test.
7. പരിപാലനം
- ഉപകരണം വൃത്തിയുള്ളതും ഉണങ്ങിയതുമായി സൂക്ഷിക്കുക. ഒരു സോഫ്റ്റ് ഉപയോഗിക്കുക, ഡിamp വൃത്തിയാക്കാനുള്ള തുണി; ഉരച്ചിലുകൾ ഉള്ള ക്ലീനറുകൾ ഒഴിവാക്കുക.
- നേരിട്ടുള്ള സൂര്യപ്രകാശത്തിൽ നിന്നും കടുത്ത താപനിലയിൽ നിന്നും മാറി തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് ഉപകരണം സൂക്ഷിക്കുക.
- Regularly check probes and test leads for damage. Replace if necessary.
- The built-in 5000mAh lithium battery supports extended field use. Charge via Type-C for uninterrupted measurements.
- Quiet fan cooling ensures stable operation. Ensure vents are not obstructed.
8. പ്രശ്നപരിഹാരം
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| തരംഗരൂപം പ്രദർശിപ്പിച്ചിട്ടില്ല. | Incorrect trigger settings, probe not connected, signal too small/large. | Check trigger mode (Auto recommended), ensure probe is connected and calibrated, adjust vertical sensitivity and time base. |
| വികലമായ തരംഗരൂപം | Improper probe compensation, bandwidth limit enabled, signal noise. | Perform probe calibration, disable 20MHz bandwidth limit if not needed, check signal source for noise. |
| Multimeter readings inaccurate | Incorrect range selected (if not in Auto), poor lead connection, battery low. | Ensure correct mode/range, check lead connections, charge battery. |
| Device freezes or malfunctions | Software glitch, thermal issue. | Perform a factory reset (Menu > Set > Factory Reset). Ensure proper ventilation. |
9 സ്പെസിഫിക്കേഷനുകൾ

Figure 9.1: Detailed product specifications for Oscilloscope, Multimeter, and Signal Generator functions.
9.1 Oscilloscope Specifications
- ചാനൽ: ഡ്യുവൽ ചാനൽ
- Sample നിരക്ക്: 500MS/സെ
- അനലോഗ് ബാൻഡ്വിഡ്ത്ത്: 100MHz
- മെമ്മറി ഡെപ്ത്: 10K, 100K, 1M
- ഇൻപുട്ട് ഇംപെഡൻസ്: 1MΩ
- Timebase Range: 5ns - 50s
- ലംബ സംവേദനക്ഷമത: 10mV - 10V/div
- പരമാവധി ഇൻപുട്ട് വോളിയംtage: 800V (x10 Probe)
- ട്രിഗർ മോഡ്: ഓട്ടോ, നോർമൽ, സിംഗിൾ
- ട്രിഗർ തരം: Rising, Falling, Both Edges
- ഡിസ്പ്ലേ മോഡ്: Dot, Vector, Color Temp
- ഇണചേരൽ: എസി/ഡിസി
- സ്ഥിരോത്സാഹം: Min/2s/5s/10s/20s/50s/∞
- Math Operations: 6 Basic Ops
- Waveform Capture: അതെ
- Waveform Export: അതെ
- കഴ്സർ അളവ്: അതെ
9.2 Multimeter Specifications
- ഡിസി വോളിയംtage: 1.9999V/19.999V/199.99V/750.0V
- എസി വോളിയംtage: 1.9999V/19.999V/199.99V/750.0V
- DC കറന്റ്: 19.999mA/1.9999A/19.999A
- എസി കറന്റ്: 19.999mA/1.9999A/19.999A
- പ്രതിരോധം: 19.999MΩ/199.99MΩ/19.999kΩ/199.99kΩ
- കപ്പാസിറ്റൻസ്: 999.9uF/19.999uF/199.99nF/19.999nF/9.999mF
- ഡയോഡ്: അതെ
- തുടർച്ച: അതെ
9.3 Signal Generator Specifications
- ചാനൽ: 1CH
- ആവൃത്തി: 0 - 10മെഗാഹെട്സ്
- Ampലിറ്റ്യൂഡ്: 0.1 - 3.0Vpp
- ഡ്യൂട്ടി സൈക്കിൾ: 0 - 100%
10. വാറൻ്റിയും പിന്തുണയും
വാറന്റി വിവരങ്ങൾക്കും സാങ്കേതിക പിന്തുണയ്ക്കും, ദയവായി നിർമ്മാതാവിന്റെ ഉദ്യോഗസ്ഥനെ കാണുക. webസൈറ്റിൽ ബന്ധപ്പെടുക അല്ലെങ്കിൽ നിങ്ങളുടെ റീട്ടെയിലറെ ബന്ധപ്പെടുക. വാറന്റി ക്ലെയിമുകൾക്കായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
11. ഉൽപ്പന്ന ഹൈലൈറ്റുകൾ
- 3-ഇൻ-1 പ്രവർത്തനം: Combines a 100MHz digital oscilloscope, 19,999-count TRMS multimeter, and 10MHz DDS signal generator.
- ഉയർന്ന പ്രകടനം: Features 500MS/s sampling rate and 100MHz bandwidth for precise signal capture.
- അവബോധജന്യമായ ഇൻ്റർഫേസ്: Equipped with a 4.3-inch IPS touchscreen for fast and easy operation.
- Advanced Analysis: Offers 13 parameters, 6 math functions, Afterglow, and Cursor measurement for detailed waveform analysis.
- മോടിയുള്ളതും പോർട്ടബിൾ: Built-in 5000mAh lithium battery, Type-C charging, quiet fan cooling, and adjustable stand for field use.