എലിടെക്-ലോഗോ

Elitech IPT-100, IPT-100S Temperature and Humidity Data Logger

സുരക്ഷാ നിർദ്ദേശങ്ങൾ

  • To ensure proper installation and usage of this product, please read carefully and follow the guidelines below:

ബാറ്ററി

  1. Use three AAA batteries. Do not use other types of batteries to avoid damaging the device or causing other malfunctions.
  2. Do not disassemble, crush, strike, or heat the batteries. Do not place them in fire, as this may cause the batteries to explode and trigger a fire.

ഉപകരണം

  1. Do not use the device in flammable or explosive gas environments to avoid the risk of explosion or fire.
  2. lf the device emits a burnt smell or other unusual odors, disconnect the power and contact the manufacturer or supplier immediately.

മുൻകരുതലുകൾ

  • If the device will not be used for an extended period, remove the batteries and store the device in a dry, cool environment.
  • Users are not allowed to make any unauthorized changes to the device.
  • Unauthorized modifications may affect the accuracy of the device or even cause damage.
  • Do not use the device outdoors to avoid malfunctions caused by rain, lightning, or other adverse weather conditions.
  • Use the device within its designated temperature and humidity range.
  • Do not subject the product to heavy impact.
  • Measurement values may be affected by the following factors:
  • താപനില പിശക്:
    • Insufficient stabilization time in the measurement environment.
      Proximity to heat or cold sources or direct exposure to sunlight.
  • ഈർപ്പം പിശക്:
    • Insufficient stabilization time in the measurement environment.Long-term exposure to steam, mist, water curtains, or condensation environments.
  • മലിനീകരണം:
    Presence of dust or other pollutants in the environment.

ഉൽപ്പന്നം കഴിഞ്ഞുview

  • The temperature and humidity meter is designed for industrial workshops, warehousespharmacies, laboratories, agricultural environments, and other professional settings for monitoring environmental temperature and humidity.

ഉൽപ്പന്ന സവിശേഷതകൾ

  • Supports OTA updates for continuous improvements.
  • ഡാറ്റ ആകാം viewed and traced through the mobile app for easier tracking.
  • Scenario-based configuration with smart alerts.
  • 4-inch large screen for clear data display.

ഉൽപ്പന്ന രൂപംElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (1)

  1.  പരമാവധി/മിനിറ്റ് ബട്ടൺ
  2. ℃/℉ toggle button
  3. Mode/Bluetooth button
  4. External probe interface
  5. കാന്തം
  6. ബാറ്ററി കവർ
  7. നിൽക്കുക
  8. External temperature sensor (Standard for IPT-100S)

ഉൽപ്പന്ന ഇന്റർഫേസ്Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (2)

  1. ബാറ്ററി ലെവൽ ഐക്കൺ
  2. ബ്ലൂടൂത്ത് ഐക്കൺ
  3. Placeholder icon (no function)
  4. അലാറം ഐക്കൺ
  5. Recording display icon
  6. External probe display mode
  7. Max/Min indicator icon
  8. സമയ പ്രദർശന മേഖല
  9. Backtrack temperature display area
  10. Backtrack time indicator area
  11. താപനില പ്രദർശന ഏരിയ
  12. Over-limit status display (over upper limitElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG 17 , over lower limitElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG 18
  13. Humidity range indicator area
  14. ഹ്യുമിഡിറ്റി ഡിസ്പ്ലേ ഏരിയ

സാങ്കേതിക പാരാമീറ്ററുകൾ

 

പരിധി അളക്കുന്നു

താപനില:-10°C~50°C
Humidity:10%RH~99%RH
 

കൃത്യത

Temperature:+0.5°C(10-35°C),+1°C for other ranges
Humidity: +5%RH(40%-75%),+10% for other ranges
 

റെസലൂഷൻ

താപനില: 0.1°C
ഈർപ്പം: 0.1% RH
വൈദ്യുതി വിതരണം 3*എഎഎ
സ്റ്റാൻഡ്ബൈ സമയം Not less than 6 months
സ്ക്രീൻ 4.5-inch segmented display
ഡാറ്റ റെക്കോർഡിംഗ് Not less than 5000 entries
ബ്ലൂടൂത്ത് ശ്രേണി Up to 30 meters in an open environment
പ്രവർത്തന പരിസ്ഥിതി -20~60℃, 0~90%RH (non-condensing)
സംഭരണ ​​പരിസ്ഥിതി -25~65℃, 0~90%RH (non-condensing)
അളവുകൾ 118.6*99.5*23.0എംഎം

Accessories External Probe

  • (Applicable only to IPT-100S with built-in external probe)
    അളക്കൽ ശ്രേണി Temperature:-20°C~70℃
    കൃത്യത Temperature:+0.5°C(0℃~40°℃),+1°C for other ranges
    റെസലൂഷൻ താപനില: 0.1℃
    ഇൻ്റർഫേസ് തരം Type-C port (Note: This port does not support charging!)
    പ്രവർത്തന പരിസ്ഥിതി -40~85℃, 0~90%RH (non-condensing)
    സംഭരണ ​​പരിസ്ഥിതി -50~90℃, 0~90%RH (non-condensing)
    സെൻസർ തരം ഡിജിറ്റൽ ടെമ്പറേച്ചർ സെൻസർ
    ലൈൻ നീളം 2 മീറ്റർ

ഉൽപ്പന്ന സവിശേഷതകൾ

  1. ഉൽപ്പന്ന സജീവമാക്കൽ
    • Remove the insulating strip from the back of the product to power it on. The screen will display all data for 2 seconds and then show the real-time readings from the internal sensor.
    • Note: After powering on, connect the device to your phone via Bluetooth to sync the time. If not in use for a long period, remove the batteries and store them separately.
    • The Type-C interface is only for connecting the external probe, not for charging.
  2. .Button Functions:
     

    ബട്ടൺ

     

    ഷോർട്ട് പ്രസ്സ്

     

    2സെ ദീർഘനേരം അമർത്തുക

    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (3) Switch between max, min, and current values Clear maximum and minimum values
    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (4) Toggle backtrack time Switch temperature unit (°C/°F)
    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (5)Switch between internal/external probe data display ബ്ലൂടൂത്ത് പ്രവർത്തനക്ഷമമാക്കുക / അപ്രാപ്‌തമാക്കുക
  3. മോഡ് സ്വിച്ചിംഗ്:
    Press the mode button to switch between the internal sensor’s temperature and humidity data and the external probe’s temperature data.
    • Note: If no external probe is connected, the external probe mode will show “—” and the external probe icon will light up.
  4. View Max/Min Values:
    • Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (6)short Press the max/min button to cycle between the maximum, minimum, and current values in the current mode.
    • Long-press the button to reset the maximum and minimum values.
  5. Humidity Indicator:
    • By default, when the humidity is below 40%, the indicator turns red to show dry conditions. Between 40%-60%, it turns green to show comfortable conditions, and above 60%, it turns blue to show humid conditions. The app allows customization of these ranges.
    • Note: Default values are based on the “Indoor Air Quality Standard” (GB/T 18883-2022)
  6. Product Alarms
     

    പ്രദർശിപ്പിക്കുക

    കാരണം പരിഹാരം
    ബീപ്പ് Current data exceeds the limit Automatic mute after 60 seconds, or press any key to mute
    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (8) Current data exceeds

    പരിധി

    Automatically cancels when data

    സാധാരണ നിലയിലേക്ക് മടങ്ങുന്നു

    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (9) Exceeded the upper limit of the display range Automatically cancels when data returns to normal
    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (10) Exceeded the lower limit of the display range

    സെൻസർ കണ്ടെത്തിയില്ല

    Automatically cancels when data returns to normal

     

    Insert or replace the sensor

    Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (11)

APP പ്രവർത്തന നിർദ്ദേശങ്ങൾ

APP കണക്ഷൻ

  1. Scan the QR code below to download and install the dedicated APP, or search for “Elitech Tools” in the app store to install.Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (12)
  2. ദീർഘനേരം അമർത്തുക Elitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (5)Bluetooth button for 2 seconds to enable Bluetooth. The Bluetooth icon will flash. Open the “Elitech Tools” app, search for nearby devices, find the correct model, and click to connect.
    • Note: Ensure your phone’s Bluetooth is enabled while using the app. The device’s Bluetooth will automatically turn off if not connected within 2 minutes.

APP ഇന്റർഫേസ് ആമുഖംElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (13)

  • The main interface displays the current built-in temperature, humidity, probe temperature, and max/min value. By clickingElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (14) , you can reset the max/min values. When the temperature or humidity exceeds the upper or lower alarm limits, the alarm icon will appear in the corresponding alarm  zoneElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (15)
  • Click the text in the upper right corner to switch Scene Mode
  • Click the dial to switch to the curve interface and view the temperature and humidity curves.
  • Click “Settings” to modify relevant parametersElitech-IPT-100,- IPT-100S-Temperature-and-Humidity-Data-Logger-FIG (16)
  • Click “Scene Settings” to select the scene you want to modify
  • Modify the alarm parameters for this scene.
  • Modify humidity range value

അറ്റാച്ച്മെന്റ് ലിസ്റ്റ്

  • Recording-type Temperature and Humidity Meter *1
  • AAA Batteries *3
  • കാന്തങ്ങൾ*2
  • External Temperature Sensor Probe *1
  • (only for IPT-100S with built-in external probe)

പതിവുചോദ്യങ്ങൾ

ചോദ്യം: ഉപകരണം പുറത്ത് ഉപയോഗിക്കാമോ?

A: No, the device should not be used outdoors to avoid malfunctions caused by adverse weather conditions.

ചോദ്യം: ഞാൻ എങ്ങനെയാണ് ഉപകരണം കാലിബ്രേറ്റ് ചെയ്യുക?

A: Calibration is not user-accessible. Please contact customer Support if you believe your device requires calibration.

പ്രമാണങ്ങൾ / വിഭവങ്ങൾ

Elitech IPT-100, IPT-100S Temperature and Humidity Data Logger [pdf] നിർദ്ദേശ മാനുവൽ
IPT-100, IPT-100S, IPT-100 IPT-100S Temperature and Humidity Data Logger, IPT-100 IPT-100S, Temperature and Humidity Data Logger, Humidity Data Logger, Data Logger, Logger

റഫറൻസുകൾ

ഒരു അഭിപ്രായം ഇടൂ

നിങ്ങളുടെ ഇമെയിൽ വിലാസം പ്രസിദ്ധീകരിക്കില്ല. ആവശ്യമായ ഫീൽഡുകൾ അടയാളപ്പെടുത്തി *