1. ആമുഖം
The Extech FL700 Fluoride Meter is a precision instrument designed for the rapid and accurate measurement of fluoride ions in various aqueous samples, including drinking water. This device integrates a sensing electrode, measurement electronics, and a digital display into a single, portable unit, making it suitable for both field and laboratory applications.
The FL700 provides direct readings of total fluoride concentrations ranging from 9.99 ppm or mg/L down to 0.1 ppm. It features automatic temperature compensation to ensure measurement accuracy across varying environmental conditions.
2 സുരക്ഷാ വിവരങ്ങൾ
Please read and understand all safety precautions before operating the Extech FL700 Fluoride Meter. Failure to follow these instructions may result in injury or damage to the instrument.
- Always handle the fluoride electrode with care. Avoid touching the sensing element directly.
- When working with TISAB reagent tablets or any chemical solutions, wear appropriate personal protective equipment, including gloves and eye protection.
- Do not immerse the entire meter in liquid. The meter is designed for electrode immersion only.
- Store the meter and reagents in a cool, dry place, away from direct sunlight and extreme temperatures.
- കുട്ടികൾക്ക് ലഭ്യമാകാതെ സൂക്ഷിക്കുക.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Extech FL700 Fluoride Meter is a compact and user-friendly device. Key components and features are outlined below:





പ്രധാന സവിശേഷതകൾ:
- രണ്ട്-പോയിന്റ് കാലിബ്രേഷൻ: Ensures accurate measurements across the fluoride range.
- മെമ്മറി സ്റ്റോറേജ്: Stores up to 25 labeled readings for later review.
- Field or lab testing: Designed for versatile use in various environments.
- Fast response: Provides fluoride measurements in less than 1 minute.
- Large dual LCD: Simultaneously displays ppm (or mg/L) and temperature with a bargraph.
4. സജ്ജീകരണം
4.1. ബാറ്ററി ഇൻസ്റ്റാളേഷൻ
The Extech FL700 requires four 3V button batteries (included). To install or replace batteries:
- Twist off the battery compartment cap located at the top of the meter.
- Insert the four 3V button batteries, ensuring correct polarity as indicated inside the compartment.
- Replace the battery compartment cap and twist to secure.
4.2. പ്രാരംഭ തയ്യാറെടുപ്പ്
Before first use or after prolonged storage, prepare the electrode:
- Remove the sensor cap from the electrode tip.
- ഇലക്ട്രോഡിന്റെ അഗ്രം വാറ്റിയെടുത്ത വെള്ളം ഉപയോഗിച്ച് കഴുകുക.
- Condition the electrode by immersing it in a fluoride standard solution (e.g., 1 ppm or 10 ppm) for approximately 15-30 minutes.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
5.1. പവർ ഓൺ/ഓഫ്
അമർത്തുക ഓൺ/ഓഫ് മീറ്റർ ഓണാക്കാനോ ഓഫാക്കാനോ ബട്ടൺ അമർത്തുക.
5.2. Calibration (Two-Point)
Accurate calibration is crucial for reliable measurements. The FL700 supports two-point calibration.
- Prepare two fluoride standard solutions, typically one low concentration (e.g., 1 ppm) and one high concentration (e.g., 10 ppm). Ensure the solutions are at a stable temperature.
- വാറ്റിയെടുത്ത വെള്ളം ഉപയോഗിച്ച് ഇലക്ട്രോഡ് കഴുകി ഉണക്കുക.
- Immerse the electrode into the first standard solution.
- അമർത്തിപ്പിടിക്കുക CAL/RECALL button until 'CAL' appears on the display. The meter will automatically recognize the standard and calibrate. Wait for the reading to stabilize.
- Rinse the electrode again and immerse it into the second standard solution.
- അമർത്തിപ്പിടിക്കുക CAL/RECALL button again. The meter will complete the two-point calibration.
- The meter is now calibrated and ready for measurement.
5.3. ഒരു അളവ് എടുക്കൽ
To measure fluoride concentration in a sampLe:
- മീറ്റർ കാലിബ്രേറ്റ് ചെയ്തിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക.
- വാറ്റിയെടുത്ത വെള്ളം ഉപയോഗിച്ച് ഇലക്ട്രോഡ് കഴുകി ഉണക്കുക.
- Add TISAB (Total Ionic Strength Adjustment Buffer) reagent to your sample according to the reagent instructions. TISAB ensures that the fluoride ions are in a measurable form and minimizes interference.
- Immerse the electrode tip into the prepared sample solution. Ensure the tip is fully submerged.
- Allow the reading to stabilize on the display. The large dual LCD will show the fluoride concentration in ppm (or mg/L) and the temperature.
- നിലവിലെ റീഡിംഗ് പിടിച്ചുനിർത്താൻ, മോഡ്/ഹോൾഡ് ബട്ടൺ. റിലീസ് ചെയ്യാൻ വീണ്ടും അമർത്തുക.
5.4. Recalling Stored Readings
The meter can store up to 25 labeled readings.
- To recall stored readings, press the CAL/RECALL button briefly when not in calibration mode.
- ഉപയോഗിക്കുക മോഡ്/ഹോൾഡ് button to scroll through the stored readings.
6. പരിപാലനം
6.1. ഇലക്ട്രോഡ് ക്ലീനിംഗ്
Regular cleaning of the electrode ensures optimal performance.
- After each use, rinse the electrode thoroughly with distilled water.
- If the electrode becomes fouled or readings become erratic, clean it with a mild detergent solution or a specialized electrode cleaning solution. Rinse thoroughly with distilled water afterward.
6.2. സംഭരണം
Proper storage extends the life of the electrode and meter.
- Always replace the sensor cap on the electrode tip when not in use. The cap should contain a small amount of electrode storage solution or a fluoride standard solution to keep the membrane hydrated. Do not store dry.
- തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് മീറ്റർ സൂക്ഷിക്കുക.
6.3. ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ
Replace batteries when the low battery indicator appears on the display or when the meter fails to power on. Refer to Section 4.1 for battery installation instructions.
7. പ്രശ്നപരിഹാരം
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| മീറ്റർ ഓൺ ആകുന്നില്ല. | മരിച്ചതോ തെറ്റായി ഇൻസ്റ്റാൾ ചെയ്തതോ ആയ ബാറ്ററികൾ | ബാറ്ററി പോളാരിറ്റി പരിശോധിക്കുക; ബാറ്ററികൾ മാറ്റിസ്ഥാപിക്കുക. |
| ക്രമരഹിതമായ അല്ലെങ്കിൽ അസ്ഥിരമായ വായനകൾ | Dirty electrode; air bubbles on electrode; insufficient sample volume; expired or incorrect TISAB. | Clean electrode; gently tap electrode to remove bubbles; ensure electrode is fully submerged; check TISAB. |
| Meter fails to calibrate | Incorrect standard solutions; dirty electrode; electrode not conditioned; damaged electrode. | Verify standard concentrations; clean and condition electrode; replace electrode if damaged. |
| കുറഞ്ഞ ബാറ്ററി സൂചകം | ബാറ്ററികൾ കുറവാണ്. | Replace all four 3V button batteries. |
8 സ്പെസിഫിക്കേഷനുകൾ
| സ്പെസിഫിക്കേഷൻ | വിശദാംശങ്ങൾ |
|---|---|
| നിർമ്മാതാവ് | എക്സ്ടെക് |
| ഭാഗം നമ്പർ | FL700 |
| ഇനത്തിൻ്റെ ഭാരം | 7.7 ഔൺസ് |
| ഉൽപ്പന്ന അളവുകൾ | 6.8 x 1.6 x 1.4 ഇഞ്ച് |
| ഇനം മോഡൽ നമ്പർ | FL700 |
| ബാറ്ററികൾ | 4 ലിഥിയം മെറ്റൽ ബാറ്ററികൾ ആവശ്യമാണ് (ഉൾപ്പെടുത്തിയിരിക്കുന്നു) |
| ശൈലി | FL700 |
| ഇനത്തിൻ്റെ പാക്കേജ് അളവ് | 1 |
| കഷണങ്ങളുടെ എണ്ണം | 1 |
| ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾ | യൂണിറ്റ്, നിർദ്ദേശ ഗൈഡ് |
| ബാറ്ററി സെൽ തരം | ആൽക്കലൈൻ |
| ആദ്യം ലഭ്യമായ തീയതി | ജൂലൈ 15, 2008 |
9. വാറൻ്റി വിവരങ്ങൾ
The Extech FL700 Fluoride Meter comes with a full one-year warranty on parts and workmanship, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modification.
10. പിന്തുണ
For technical support, service, or additional information, please visit the official Extech webസൈറ്റിൽ ബന്ധപ്പെടുക അല്ലെങ്കിൽ അവരുടെ ഉപഭോക്തൃ സേവന വിഭാഗവുമായി ബന്ധപ്പെടുക. കൂടുതൽ വിവരങ്ങളും ഉൽപ്പന്നങ്ങളും നിങ്ങൾക്ക് ഇവിടെ കണ്ടെത്താനാകും. Extech Store on Amazon.