1. ആമുഖം
The Extech LCR200 is a passive component LCR meter designed for precise measurements of inductance, capacitance, and resistance. This device offers a simultaneous 20,000/2,000 count display for primary and secondary parameters on its high-contrast backlit screen. It supports various functions including Hi/Lo limit settings, Open and Short Zero calibration to remove stray impedances, and an Auto Power Off feature. The meter is supplied with a built-in test fixture and external test leads, powered by a 9V battery.
2 പ്രധാന സവിശേഷതകൾ
- Measures inductance (L), capacitance (C), and resistance (R).
- Displays secondary parameters: Quality Factor (Q), Dissipation (D), Phase (P), and Equivalent Series Resistance (ESR).
- Dual backlit display with 20,000/2,000 count for primary and secondary parameters.
- Supports Open and Short calibration to eliminate stray impedance.
- Five selectable test frequencies: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz.
- Selectable series or parallel circuit measurement modes.
- Adjustable limit settings (Hi/Lo) using absolute values or percentages.
- Auto Power Off function (with override option).
- കുറഞ്ഞ ബാറ്ററി സൂചകം.
3. പാക്കേജ് ഉള്ളടക്കം
The Extech LCR200 package includes:
- Extech LCR200 Passive Component LCR Meter
- Built-in test fixture
- External test leads with alligator clips
- 9V ബാറ്ററി
4. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Extech LCR200 meter is designed for ease of use and accurate component testing. Below is an image illustrating the meter's display, control buttons, and input terminals.

The front panel includes a large LCD for displaying measurement results, function buttons (FREQ, HOLD, L/C/R, CAL, D/Q/θ, REL/%/↑, ENTER, SER/PAR, SORT, SETUP, Power, Backlight), and input jacks for connecting test leads. A 'GUARD' terminal is also present for advanced measurement configurations.
5. സജ്ജീകരണം
5.1 ബാറ്ററി ഇൻസ്റ്റാളേഷൻ
The LCR200 operates on a single 9V battery. To install or replace the battery:
- മീറ്ററിന്റെ പിൻഭാഗത്ത് ബാറ്ററി കമ്പാർട്ട്മെന്റ് കവർ കണ്ടെത്തുക.
- Remove the screw(s) securing the cover and open it.
- ശരിയായ പോളാരിറ്റി നിരീക്ഷിച്ചുകൊണ്ട്, ബാറ്ററി കണക്ടറിലേക്ക് ഒരു പുതിയ 9V ബാറ്ററി ബന്ധിപ്പിക്കുക.
- ബാറ്ററി കമ്പാർട്ടുമെന്റിൽ വയ്ക്കുക, കവർ മാറ്റി സ്ക്രൂ(കൾ) ഉപയോഗിച്ച് ഉറപ്പിക്കുക.
5.2 പ്രാരംഭ പവർ ഓൺ
അമർത്തുക ശക്തി button (red circle with line) to turn the unit on. The meter will perform a brief self-test before entering the default measurement mode.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
6.1 Measurement Modes (L/C/R)
അമർത്തുക L/C/R button to cycle through Inductance, Capacitance, and Resistance measurement modes. The meter can also automatically detect the component type.
6.2 Secondary Parameter Display
അമർത്തുക D/Q/θ button to cycle through the display of secondary parameters: Dissipation (D), Quality Factor (Q), Phase (θ), and Equivalent Series Resistance (ESR).
6.3 Test Frequency Selection
അമർത്തുക FREQ button to select one of the five available test frequencies: 100Hz, 120Hz, 1kHz, 10kHz, or 100kHz. The optimal frequency depends on the component type and value being measured.
6.4 Open and Short Calibration
To ensure accurate measurements by removing stray impedances from test leads or the built-in fixture, perform an Open and Short calibration:
- With no component connected to the test terminals, press the CAL button to perform an Open circuit calibration.
- Short the test terminals (e.g., by connecting the test leads together or inserting a shorting bar into the built-in fixture), then press the CAL button again to perform a Short circuit calibration.
6.5 Series/Parallel Measurement Modes
അമർത്തുക SER/PAR button to switch between series and parallel circuit measurement modes. The meter can also automatically select the appropriate mode.
6.6 ഡാറ്റ ഹോൾഡ് പ്രവർത്തനം
അമർത്തുക പിടിക്കുക ഡിസ്പ്ലേയിൽ നിലവിലെ റീഡിംഗ് ഫ്രീസ് ചെയ്യാൻ ബട്ടൺ അമർത്തുക. ഹോൾഡ് വിടുന്നതിനും തത്സമയ അളവുകൾ പുനരാരംഭിക്കുന്നതിനും അത് വീണ്ടും അമർത്തുക.
6.7 Component Sorting (Hi/Lo Limits)
ദി അടുക്കുക function allows you to set Hi/Lo limits for component testing, enabling quick sorting of components based on tolerance. Use the navigation buttons to set the reference value and tolerance percentage.
6.8 ഓട്ടോ പവർ ഓഫ്
The meter automatically powers off after 5 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required (refer to the full manual for specific instructions).
7. പരിപാലനം
7.1 ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ
When the low battery indicator appears on the display, replace the 9V battery as described in Section 5.1.
7.2 വൃത്തിയാക്കൽ
മീറ്ററിന്റെ സി തുടയ്ക്കുകasing with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the plastic components or display.
7.3 സംഭരണം
If the meter is not to be used for an extended period, remove the battery to prevent leakage. Store the device in a dry, dust-free environment away from direct sunlight and extreme temperatures.
8. പ്രശ്നപരിഹാരം
- No Display or Power On: Ensure the 9V battery is correctly installed and has sufficient charge. Replace the battery if necessary.
- കൃത്യമല്ലാത്ത വായനകൾ: Perform an Open and Short calibration (Section 6.4). Verify that test leads are securely connected. Select the appropriate test frequency and series/parallel measurement mode for the component being tested.
- Difficulty with Built-in Test Fixture: Some users may experience stiff internal contacts in the built-in test fixture, making it difficult to insert component leads without bending them. If this occurs, utilize the external test leads with alligator clips provided with the meter for easier connection.
- Data Out Port Not Functioning: The 'Data Out' port on the LCR200 model is not implemented for data transmission. This is a design specification and not a malfunction.
9 സ്പെസിഫിക്കേഷനുകൾ
| പരാമീറ്റർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| ബ്രാൻഡ് | എക്സ്ടെക് |
| മോഡൽ | LCR200 |
| അളക്കൽ തരം | എൽസിആർ മീറ്റർ |
| പവർ ഉറവിടം | ബാറ്ററി പവർ |
| വാല്യംtage | 9 വോൾട്ട് |
| ഇനത്തിൻ്റെ ഭാരം | 0.43 കിലോഗ്രാം (15.1 ഔൺസ്) |
| ഉൽപ്പന്ന അളവുകൾ (L x W x H) | 7.6 x 3.5 x 1.6 ഇഞ്ച് |
| അളക്കൽ കൃത്യത | +/-0.5% |
| പരീക്ഷണ ആവൃത്തികൾ | 100Hz, 120Hz, 1kHz, 10kHz, 100kHz |
| യു.പി.സി | 793950360200 |
10. ഓപ്ഷണൽ ആക്സസറികൾ
Extech offers additional accessories to enhance the functionality of your LCR200 meter:
- LCR203 Tweezer Test Leads: Designed for convenient connection and testing of small chip components.
- LCR205 SMD Test Fixture: A specialized fitting that plugs into the meter's integral connectors, allowing for precise testing of surface mount device (SMD) components.
11. വാറൻ്റിയും പിന്തുണയും
For detailed warranty information, technical assistance, or to inquire about service, please contact Extech customer support directly or visit the official Extech webവാറന്റി ക്ലെയിമുകൾക്കുള്ള വാങ്ങലിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.